NUMERICAL INVESTIGATION OF BLADE DYNAMIC CHARACTERISTICS IN AN AXIAL FLOW PUMP
暂无分享,去创建一个
The unsteady numerical simulation of fluid field and structural transient dynamic analysis of axial flow pump were carried out at three operating conditions based on fluid-structure interaction method. Numerical results show that the maximum equivalent stress of impeller occurs at the joint region of the impeller blade root and the hub, and the maximum deformation of impeller occurs at the tips of blade leading edges. The frequency-domain of the maximum equivalent stress and outlet pressure fluctuation of impeller are mainly affected by the impeller blade passing frequency.
[1] Lixiang Zhang,et al. FEM simulation of turbulent flow in a turbine blade passage with dynamical fluid–structure interaction , 2009 .
[2] Weidong Shi,et al. Unsteady Flow Analysis and Experimental Investigation of Axial-Flow Pump , 2010 .
[3] Dara W. Childs. Fluid-Structure Interaction Forces at Pump-Impeller-Shroud Surfaces for Axial Vibration Analysis , 1991 .
[4] Jianping,et al. Numerical Investigation on Fluid Structure Interaction Considering Rotor Deformation for a Centrifugal Pump , 2011 .