Intraoperative MRI for optimizing electrode placement for deep brain stimulation of the subthalamic nucleus in Parkinson disease.

OBJECT The degree of clinical improvement achieved by deep brain stimulation (DBS) is largely dependent on the accuracy of lead placement. This study reports on the evaluation of intraoperative MRI (iMRI) for adjusting deviated electrodes to the accurate anatomical position during DBS surgery and acute intracranial changes. METHODS Two hundred and six DBS electrodes were implanted in the subthalamic nucleus (STN) in 110 patients with Parkinson disease. All patients underwent iMRI after implantation to define the accuracy of lead placement. Fifty-six DBS electrode positions in 35 patients deviated from the center of the STN, according to the result of the initial postplacement iMRI scans. Thus, we adjusted the electrode positions for placement in the center of the STN and verified this by means of second or third iMRI scans. Recording was performed in adjusted parameters in the x-, y-, and z-axes. RESULTS Fifty-six (27%) of 206 DBS electrodes were adjusted as guided by iMRI. Electrode position was adjusted on the basis of iMRI 62 times. The sum of target coordinate adjustment was -0.5 mm in the x-axis, -4 mm in the y-axis, and 15.5 mm in the z-axis; the total of distance adjustment was 74.5 mm in the x-axis, 88 mm in the y-axis, and 42.5 mm in the z-axis. After adjustment with the help of iMRI, all electrodes were located in the center of the STN. Intraoperative MRI revealed 2 intraparenchymal hemorrhages in 2 patients, brain shift in all patients, and leads penetrating the lateral ventricle in 3 patients. CONCLUSIONS The iMRI technique can guide surgeons as they adjust deviated electrodes to improve the accuracy of implanting the electrodes into the correct anatomical position. The iMRI technique can also immediately demonstrate acute changes such as hemorrhage and brain shift during DBS surgery.

[1]  G. Schaltenbrand,et al.  Atlas for Stereotaxy of the Human Brain , 1977 .

[2]  G. Westby,et al.  Targeting the subthalamic nucleus for deep brain stimulation: technical approach and fusion of pre- and postoperative MR images to define accuracy of lead placement , 2005, Journal of Neurology, Neurosurgery & Psychiatry.

[3]  R A Bakay,et al.  Ablative surgery and deep brain stimulation for Parkinson's disease. , 1999, Neurosurgery.

[4]  A. Morel,et al.  Multiarchitectonic and stereotactic atlas of the human thalamus , 1997, The Journal of comparative neurology.

[5]  Marwan I. Hariz,et al.  Safety and Risk of Microelectrode Recording in Surgery for Movement Disorders , 2003, Stereotactic and Functional Neurosurgery.

[6]  M. Bernstein,et al.  Intraoperative magnetic resonance imaging findings during deep brain stimulation surgery. , 2011, Journal of neurosurgery.

[7]  Vincent Dousset,et al.  Lack of agreement between direct magnetic resonance imaging and statistical determination of a subthalamic target: the role of electrophysiological guidance. , 2002, Journal of neurosurgery.

[8]  Paul S Larson,et al.  Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy. , 2010, Journal of neurosurgery.

[9]  S. Gill,et al.  MRI directed bilateral stimulation of the subthalamic nucleus in patients with Parkinson’s disease , 2003, Journal of neurology, neurosurgery, and psychiatry.

[10]  Paul Krack,et al.  Intraoperative microrecordings of the subthalamic nucleus in Parkinson's disease , 2002, Movement disorders : official journal of the Movement Disorder Society.

[11]  Aviva Abosch,et al.  Safety of magnetic resonance imaging of deep brain stimulator systems: a serial imaging and clinical retrospective study. , 2010, Journal of neurosurgery.

[12]  T. Aziz,et al.  The pallidotomy debate. , 1998, British Journal of Neurosurgery.

[13]  P J Kelly,et al.  Comparison of anatomic and neurophysiological methods for subthalamic nucleus targeting. , 2000, Neurosurgery.

[14]  W. Hamel,et al.  Documentation of electrode localization , 2002, Movement disorders : official journal of the Movement Disorder Society.

[15]  M. Hariz,et al.  Do Microelectrode Techniques Increase Accuracy or Decrease Risks in Pallidotomy and Deep Brain Stimulation? , 2000, Stereotactic and Functional Neurosurgery.

[16]  A. Benabid,et al.  Five-year follow-up of bilateral stimulation of the subthalamic nucleus in advanced Parkinson's disease. , 2003, The New England journal of medicine.

[17]  A. Benabid,et al.  Long‐Term Electrical Inhibition of Deep Brain Targets in Movement Disorders , 2008, Movement disorders : official journal of the Movement Disorder Society.

[18]  G Evren Keles Intracranial neuronavigation with intraoperative magnetic resonance imaging , 2004, Current opinion in neurology.

[19]  Alastair J. Martin,et al.  Magnetic Resonance Imaging of Implanted Deep Brain Stimulators: Experience in a Large Series , 2007, Stereotactic and Functional Neurosurgery.

[20]  G. Deuschl,et al.  Surgical treatment of Parkinson's disease. , 1999, Current opinion in neurology.

[21]  A. Benabid,et al.  Effect on parkinsonian signs and symptoms of bilateral subthalamic nucleus stimulation , 1995, The Lancet.

[22]  Jens Volkmann,et al.  Bilateral high-frequency stimulation in the subthalamic nucleus for the treatment of Parkinson disease: correlation of therapeutic effect with anatomical electrode position. , 2002, Journal of neurosurgery.

[23]  J. Dostrovsky,et al.  Microelectrode monitoring of cortical and subcortical structures during stereotactic surgery. , 1995, Acta neurochirurgica. Supplement.

[24]  Michael S. Okun,et al.  Safety of MRI in patients with implanted deep brain stimulation devices , 2009, NeuroImage.

[25]  Y. Agid,et al.  Bilateral subthalamic stimulation for Parkinson's disease by using three-dimensional stereotactic magnetic resonance imaging and electrophysiological guidance. , 2000, Journal of neurosurgery.