Scanning x‐ray microscope with 75‐nm resolution

A scanning soft x‐ray microscope has been built and operated at the National Synchrotron Light Source. It makes use of a mini‐undulator as a bright source of 3.2‐nm photons. An electron beam fabricated Fresnel zone plate focuses the beam onto the specimen, which is scanned under computer control. The scanning stage can be moved by both piezoelectric transducers and stepping motors, and the location is monitored by a high‐speed laser interferometer. X rays transmitted through the specimen are detected using a flow proportional counter. Images of biological specimens and of artificial microstructures have been made with resolution in the 75–100‐nm range. Acquisition time for 256×256‐pixel images is about 5 min.

[1]  Ping-chin Cheng,et al.  X-Ray Microscopy: Instrumentation and Biological Applications , 1987 .

[2]  J. Kirz,et al.  Quantitative imaging and microanalysis with a scanning soft x-ray microscope. , 1987, Physics in Medicine and Biology.

[3]  Ian McNulty,et al.  An Undulator Based Scanning Microscope At The National Synchrotron Light Source , 1986, Optics & Photonics.

[4]  Harvey Rarback,et al.  Predictions On The Performance Of The Soft X-Ray Undulator , 1986, Other Conferences.

[5]  P. Cheng,et al.  Laser X-ray microscopy , 1986 .

[6]  H. Beneking,et al.  Electron beam lithography and nanometer structures-fabrication of microzone plates , 1986, Other Conferences.

[7]  B. Niemann,et al.  The Gottingen Scanning X-ray Microscope , 1986, Other Conferences.

[8]  John M. Kenney,et al.  King's College London/SERC Daresbury Scanning X-ray Microscope , 1986, Other Conferences.

[9]  D. Attwood,et al.  Tunable Coherent X-rays , 1985, Science.

[10]  J. Kirz,et al.  Soft x‐ray microscopes , 1985 .

[11]  J. Cazaux,et al.  Scanning X-ray radiography with an improved detection scheme , 1985 .

[12]  Raul E. Acosta,et al.  Electron Beam Fabrication And Characterization Of Fresnel Zone Plates For Soft X-Ray Microscopy , 1984, Other Conferences.

[13]  R. Rosser High Resolution Soft X-ray Optics , 1983 .

[14]  江橋 節郎,et al.  Handbook on synchrotron radiation , 1983 .

[15]  G. Schmahl,et al.  Status Of The Sputtered Sliced Zone Plates For X-Ray Microscopy , 1982, Other Conferences.

[16]  Harvey Rarback,et al.  Optical Performance Of Apodized Zone Plates , 1982, Other Conferences.

[17]  Sebastian Doniach,et al.  Synchrotron Radiation Research , 1978, Springer US.

[18]  E. A. Ash,et al.  Scanned image microscopy , 1980 .

[19]  P. Horowitz SOME EXPERIENCES WITH X‐RAY AND PROTON MICROSCOPES * , 1978 .

[20]  G. Schmahl,et al.  High power zone plates as image forming systems for soft X-rays. , 1969 .

[21]  Raj Mittra,et al.  Resolving Power of a Zone Plate , 1967 .

[22]  M. De Handbuch der Physik , 1957 .

[23]  P. Kirkpatrick,et al.  Formation of optical images by X-rays. , 1948, Journal of the Optical Society of America.