Automatic segmentation of the left ventricle cavity and myocardium in MRI data

A novel approach for the automatic segmentation has been developed to extract the epi-cardium and endo-cardium boundaries of the left ventricle (lv) of the heart. The developed segmentation scheme takes multi-slice and multi-phase magnetic resonance (MR) images of the heart, transversing the short-axis length from the base to the apex. Each image is taken at one instance in the heart's phase. The images are segmented using a diffusion-based filter followed by an unsupervised clustering technique and the resulting labels are checked to locate the (lv) cavity. From cardiac anatomy, the closest pool of blood to the lv cavity is the right ventricle cavity. The wall between these two blood-pools (interventricular septum) is measured to give an approximate thickness for the myocardium. This value is used when a radial search is performed on a gradient image to find appropriate robust segments of the epi-cardium boundary. The robust edge segments are then joined using a normal spline curve. Experimental results are presented with very encouraging qualitative and quantitative results and a comparison is made against the state-of-the art level-sets method.

[1]  Dana H. Ballard,et al.  Computer Vision , 1982 .

[2]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Circulation.

[3]  E Fleck,et al.  Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography. , 2001, The American journal of cardiology.

[4]  Demetri Terzopoulos,et al.  A dynamic finite element surface model for segmentation and tracking in multidimensional medical images with application to cardiac 4D image analysis. , 1995, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[5]  Martin Urschler,et al.  The Live Wire Approach for the Segmentation of Left Ventricle Electron-Beam CT Images , 2002 .

[6]  C. Hatton,et al.  Reducing the Risks , 1968, Nature.

[7]  J A Sethian,et al.  A fast marching level set method for monotonically advancing fronts. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[8]  Ke Chen,et al.  A Feature-Preserving Adaptive Smoothing Method for Early Vision , 2000 .

[9]  Milan Sonka,et al.  Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR images , 2001, IEEE Transactions on Medical Imaging.

[10]  Laurent D. Cohen,et al.  Real-Time Interactive Path Extraction with on-the-Fly Adaptation of the External Forces , 2002, ECCV.

[11]  T W Redpath,et al.  Determination of normal regional left ventricular function from cine-MR images using a semi-automated edge detection method. , 1999, Magnetic resonance imaging.

[12]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[13]  Azriel Rosenfeld,et al.  Computer Vision , 1988, Adv. Comput..

[14]  Baba C. Vemuri,et al.  Shape Modeling with Front Propagation: A Level Set Approach , 1995, IEEE Trans. Pattern Anal. Mach. Intell..

[15]  Charles B. Higgins,et al.  Cardiovascular MRI and MRA , 2002 .

[16]  Dudley J Pennell,et al.  Assessment of Left Ventricular Mass by Cardiovascular Magnetic Resonance , 2002, Hypertension.

[17]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[18]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[19]  Milan Sonka,et al.  Segmentation of cardiac MR volume data using 3D active appearance models , 2002, SPIE Medical Imaging.

[20]  James S. Duncan,et al.  Boundary Finding with Parametrically Deformable Models , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[21]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[22]  Jim Graham,et al.  Robust Active Shape Model Search , 2002, ECCV.

[23]  Johan Montagnat,et al.  A review of deformable surfaces: topology, geometry and deformation , 2001, Image Vis. Comput..

[24]  G. Hamarneh,et al.  Combining snakes and active shape models for segmenting the human left ventricle in echocardiographic images , 2000, Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163).

[25]  Richard O. Duda,et al.  Pattern classification and scene analysis , 1974, A Wiley-Interscience publication.

[26]  Jasjit S. Suri,et al.  Computer Vision, Pattern Recognition and Image Processing in Left Ventricle Segmentation: The Last 50 Years , 2000, Pattern Analysis & Applications.

[27]  G. I. Sanchez-Ortiz,et al.  Fuzzy clustering driven anisotropic diffusion: enhancement and segmentation of cardiac MR images , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[28]  J. Suri,et al.  Advanced algorithmic approaches to medical image segmentation: state-of-the-art application in cardiology, neurology, mammography and pathology , 2001 .

[29]  Sameer Singh,et al.  A comparison of state-of-the-art diffusion imaging techniques for smoothing medical/non-medical image data , 2002, Object recognition supported by user interaction for service robots.

[30]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[31]  R P Velthuizen,et al.  MRI segmentation: methods and applications. , 1995, Magnetic resonance imaging.

[32]  Alejandro F. Frangi,et al.  Three-dimensional modeling for functional analysis of cardiac images, a review , 2001, IEEE Transactions on Medical Imaging.

[33]  Sameer Singh,et al.  Advanced Algorithmic Approaches to Medical Image Segmentation , 2002, Advances in Computer Vision and Pattern Recognition.

[34]  Timothy F. Cootes,et al.  Active Appearance Models , 1998, ECCV.

[35]  Daniel Rueckert,et al.  Knowledge-based tensor anisotropic diffusion of cardiac magnetic resonance images , 1999, Medical Image Anal..

[36]  Marcel Breeuwer,et al.  Detection of left ventricular epi-and endocardial borders using coupled active contours , 2003, CARS.

[37]  Ioannis A. Kakadiaris,et al.  Cardiac image analysis: morphology, function, and dynamics , 2003 .

[38]  U. Högberg,et al.  The World Health report 2002. , 2003, Midwifery.

[39]  Konstantina S. Nikita,et al.  MR functional cardiac imaging: Segmentation, measurement and WWW based visualisation of 4D data , 1999, Future Gener. Comput. Syst..

[40]  James S. Duncan,et al.  Deformable boundary finding in medical images by integrating gradient and region information , 1996, IEEE Trans. Medical Imaging.

[41]  J. Alison Noble,et al.  Automating 3D Echocardiographic Image Analysis , 2000, MICCAI.

[42]  T. Prentice,et al.  World Health report 2002: reducing risks, promoting health life , 2002 .

[43]  J. A. Hartigan,et al.  A k-means clustering algorithm , 1979 .

[44]  J. Hogg Magnetic resonance imaging. , 1994, Journal of the Royal Naval Medical Service.

[45]  J. Sethian,et al.  FRONTS PROPAGATING WITH CURVATURE DEPENDENT SPEED: ALGORITHMS BASED ON HAMILTON-JACOB1 FORMULATIONS , 2003 .

[46]  Paul F. Whelan,et al.  Calculation of the ejection fraction (EF) from MR cardio-images , 2003 .

[47]  Guido Gerig,et al.  Nonlinear anisotropic filtering of MRI data , 1992, IEEE Trans. Medical Imaging.

[48]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[49]  S Sideman,et al.  Three-dimensional mapping of acute ischemic regions using MRI: wall thickening versus motion analysis. , 1990, The American journal of physiology.

[50]  M. Lynch,et al.  Extraction of epi-cardium contours from unseen images using a shape database , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[52]  V Positano,et al.  Automated cardiac MR image segmentation: theory and measurement evaluation. , 2003, Medical engineering & physics.

[53]  Peter E. Hilsenrath,et al.  The World Health Report 2000 , 2002 .

[54]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[55]  James A. Sethian,et al.  Level Set Methods for Curvature Flow, Image Enchancement, and Shape Recovery in Medical Images , 1997, VisMath.

[56]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[57]  C. Higgins,et al.  Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data. , 1993, Radiology.

[58]  O Ratib,et al.  Osiris: a medical image-manipulation system. , 1994, M.D. computing : computers in medical practice.

[59]  Milan Sonka,et al.  Automatic segmentation of echocardiographic sequences by active appearance motion models , 2002, IEEE Transactions on Medical Imaging.

[60]  Christian Barillot,et al.  Multidimensional ultrasonic imaging for cardiology , 1988, Proc. IEEE.

[61]  Jerry L. Prince,et al.  A Survey of Current Methods in Medical Image Segmentation , 1999 .

[62]  Demetri Terzopoulos,et al.  Deformable models in medical image analysis: a survey , 1996, Medical Image Anal..