Effects of repetitive subfailure strains on the mechanical behavior of the inferior glenohumeral ligament.

The mechanical response of the inferior glenohumeral ligament to varying subfailure cyclic strains was studied in 33 fresh frozen human cadaver shoulders. The specimens were tested as bone-ligament-bone preparations representing the 3 regions of the inferior glenohumeral ligament (superior band and anterior and posterior axillary pouches) through use of uniaxial tensile cycles. After mechanical preconditioning, each specimen was subjected to 7 test segments, consisting of a baseline strain level L1 (400 cycles) alternating with either 1 (group A, 10 shoulders), 10 (group B, 13 shoulders), or 100 (group C, 10 shoulders) cycles at increasing levels (L2, L3, L4) of subfailure strain. Cycling to higher levels of subfailure strain (L2, L3, L4) produced dramatic declines in the peak load response of the inferior glenohumeral ligament for all specimens. The group of ligaments subjected to 100 cycles of higher subfailure strains demonstrated a significantly greater decrease in load response than the other 2 groups. Ligament elongation occurred with cyclic testing at subfailure strains for all 3 groups, averaging 4.6% +/- 2.0% for group A, 6.5% +/- 2.6% for group B, and 7.1% +/- 3.2% for group C. Recovery of length after an additional time of nearly 1 hour was minimal. The results from this study demonstrate that repetitive loading of the inferior glenohumeral ligament induces laxity in the ligament, as manifested in the peak load response and measured elongations. The mechanical response of the ligament is affected by both the magnitude of the cyclic strain and the frequency of loading at the higher strain levels. The residual length increase was observed in all of the specimens and appeared to be largely unrecoverable. This length increase may result from accumulated microdamage within the ligament substance, caused by the repetitively applied subfailure strains. The clinical relevance of the study is that this mechanism may contribute to the development of acquired glenohumeral instability, which is commonly seen in the shoulders of young athletes who participate in repetitive overhead sports activities.

[1]  R. Haut,et al.  The effects of test environment and cyclic stretching on the failure properties of human patellar tendons , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  G C Terry,et al.  The stabilizing function of passive shoulder restraints , 1991, The American journal of sports medicine.

[3]  Freddie H. Fu,et al.  Dynamic capsuloligamentous anatomy of the glenohumeral joint. , 1993, Journal of shoulder and elbow surgery.

[4]  R. Shadwick,et al.  Elastic energy storage in tendons: mechanical differences related to function and age. , 1990, Journal of applied physiology.

[5]  S. Nielsen,et al.  Stability of the shoulder joint. Cadaver study of stabilizing structures. , 1985, Acta orthopaedica Scandinavica.

[6]  A Viidik,et al.  Changes in tensile strength characteristics and histology of rabbit ligaments induced by different modes of postmortal storage. , 1966, Acta orthopaedica Scandinavica.

[7]  Y. Fung,et al.  Biomechanics: Mechanical Properties of Living Tissues , 1981 .

[8]  T. Wickiewicz,et al.  The anatomy and histology of the inferior glenohumeral ligament complex of the shoulder , 1990, The American journal of sports medicine.

[9]  R. J. Pawluk,et al.  Tensile properties of the inferior glenohumeral ligament , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  Y. Fung,et al.  Bio-viscoelastic Solids , 1981 .

[11]  Y. Fung Elasticity of soft tissues in simple elongation. , 1967, The American journal of physiology.

[12]  F R Noyes,et al.  Biomechanics of anterior cruciate ligament failure: an analysis of strain-rate sensitivity and mechanisms of failure in primates. , 1974, The Journal of bone and joint surgery. American volume.

[13]  R. J. Pawluk,et al.  Inferior glenohumeral ligament: geometric and strain-rate dependent properties. , 1996, Journal of shoulder and elbow surgery.

[14]  N. Poppen,et al.  Normal and abnormal motion of the shoulder. , 1976, The Journal of bone and joint surgery. American volume.

[15]  V C Mow,et al.  The intrinsic tensile behavior of the matrix of bovine articular cartilage and its variation with age. , 1980, The Journal of bone and joint surgery. American volume.

[16]  R. Vanderby,et al.  Effect of preconditioning on the viscoelastic response of primate patellar tendon. , 1994, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[17]  G. Nuber,et al.  The contribution of the glenohumeral ligaments to anterior stability of the shoulder joint , 1990, The American journal of sports medicine.

[18]  S L Woo,et al.  The time and history-dependent viscoelastic properties of the canine medical collateral ligament. , 1981, Journal of biomechanical engineering.

[19]  R. Guldberg,et al.  Anterior shoulder stability: Contributions of rotator cuff forces and the capsular ligaments in a cadaver model. , 1992, Journal of shoulder and elbow surgery.

[20]  F. Girgis,et al.  Stabilizing mechanisms preventing anterior dislocation of the glenohumeral joint. , 1981, The Journal of bone and joint surgery. American volume.

[21]  K J Chun,et al.  Mechanical responses of tendons to repeated extensions and wait periods. , 1988, Journal of biomechanical engineering.

[22]  F. Noyes,et al.  Effects of structure and strain measurement technique on the material properties of young human tendons and fascia. , 1984, Journal of biomechanics.

[23]  R. Welsh,et al.  The shoulder in sports , 1974, The Journal of sports medicine.

[24]  S L Woo,et al.  Temperature dependent behavior of the canine medial collateral ligament. , 1987, Journal of biomechanical engineering.

[25]  C. Frank,et al.  Changes in the cyclic and static relaxations of the rabbit medial collateral ligament complex during maturation. , 1993, Journal of biomechanics.

[26]  L. Bigliani,et al.  Inferior Capsular Shift Procedure for Anterior-inferior Shoulder Instability in Athletes* , 1994, The American journal of sports medicine.

[27]  A. Viidik,et al.  Structure and Function of Normal and Healing Tendons and Ligaments , 1990 .

[28]  M M Panjabi,et al.  Subfailure injury of the rabbit anterior cruciate ligament , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[29]  D L Bader,et al.  In vitro fatigue of human tendons. , 1997, Journal of biomechanics.

[30]  Savio Lau-Yuen Woo,et al.  Biomechanics of diarthrodial joints , 1990 .

[31]  R J Johnson,et al.  Cyclic loading in knee ligament injuries , 1980, The American journal of sports medicine.

[32]  S L Woo,et al.  The mechanical properties of skeletally mature rabbit anterior cruciate ligament and patellar tendon over a range of strain rates , 1993, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.