Evaluation of the effect of reducing administered activity on assessment of function in cardiac gated SPECT

Background We previously optimized several reconstruction strategies in SPECT myocardial perfusion imaging (MPI) with low dose for perfusion-defect detection. Here we investigate whether reducing the administered activity can also maintain the diagnostic accuracy in evaluating cardiac function. Methods We quantified the myocardial motion in cardiac-gated stress 99m-Tc-sestamibi SPECT studies from 163 subjects acquired with full dose (29.8 ± 3.6 mCi), and evaluated the agreement of the obtained motion/thickening and ejection fraction (EF) measures at various reduced dose levels (uniform reduction or personalized dose) with that at full dose. We also quantified the detectability of abnormal motion via a receiver-operating characteristics (ROC) study. For reconstruction we considered both filtered backprojection (FBP) without correction for degradations, and iterative ordered-subsets expectation-maximization (OS-EM) with resolution, attenuation and scatter corrections. Results With dose level lowered to 25% of full dose, the obtained results on motion/thickening, EF and abnormal motion detection were statistically comparable to full dose in both reconstruction strategies, with Pearson’s r  > 0.9 for global motion measures between low dose and full dose. Conclusions The administered activity could be reduced to 25% of full dose without degrading the function assessment performance. Low dose reconstruction optimized for perfusion-defect detection can be reasonable for function assessment in gated SPECT.

[1]  G. Keppel,et al.  Design and Analysis: A Researcher's Handbook , 1976 .

[2]  E L Ritman,et al.  Invariant total heart volume in the intact thorax. , 1985, The American journal of physiology.

[3]  K. Ogawa,et al.  A practical method for position-dependent Compton-scatter correction in single photon emission CT. , 1991, IEEE transactions on medical imaging.

[4]  B. Chaitman,et al.  Exercise Technetium‐99m Sestamibi Tomography for Cardiac Risk Stratification of Patients With Stable Chest Pain , 1994, Circulation.

[5]  D. Berman,et al.  Exercise myocardial perfusion SPECT in patients without known coronary artery disease: incremental prognostic value and use in risk stratification. , 1996, Circulation.

[6]  Michael A. King,et al.  AN INVESTIGATION OF THE FILTERING OF TEW SCATTER ESTIMATES USED TO COMPENSATE FOR SCATTER WITH ORDERED SUBSET RECONSTRUCTIONS , 1996 .

[7]  Joon Young Choi,et al.  Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT , 1998, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[8]  R. Huesman,et al.  Cardiac gating of transmission data is unnecessary for attenuation compensation of double-gated emission scans , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[9]  L. Shao,et al.  A generalized model for the conversion from CT numbers to linear attenuation coefficients , 2002 .

[10]  M. King,et al.  Human-observer receiver-operating-characteristic evaluation of attenuation, scatter, and resolution compensation strategies for (99m)Tc myocardial perfusion imaging. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  D. F. Morrison Multivariate Analysis of Variance , 2005 .

[12]  Piotr J. Slomka,et al.  Quantitation in gated perfusion SPECT imaging: The Cedars-Sinai approach , 2007, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[13]  J. Piccini,et al.  Single-Photon Emission Computed Tomography Myocardial Perfusion Defects Are Associated With an Increased Risk of All-Cause Death, Cardiovascular Death, and Sudden Cardiac Death , 2008, Circulation. Cardiovascular imaging.

[14]  Giorgio Iervasi,et al.  Stress/Rest Myocardial Perfusion Abnormalities by Gated SPECT: Still the Best Predictor of Cardiac Events in Stable Ischemic Heart Disease , 2009, Journal of Nuclear Medicine.

[15]  Edward P. Ficaro,et al.  Recommendations for reducing radiation exposure in myocardial perfusion imaging , 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[16]  D. Berman,et al.  Fully automated wall motion and thickening scoring system for myocardial perfusion SPECT: Method development and validation in large population , 2012, Journal of Nuclear Cardiology.

[17]  M. King,et al.  4D reconstruction for low-dose cardiac gated SPECT. , 2013, Medical physics.

[18]  Leslee J Shaw,et al.  Nationwide Laboratory Adherence to Myocardial Perfusion Imaging Radiation Dose Reduction Practices: A Report From the Intersocietal Accreditation Commission Data Repository. , 2015, JACC. Cardiovascular imaging.

[19]  M. Vauhkonen,et al.  Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT , 2015, Journal of Nuclear Cardiology.

[20]  Giovanni Lucignani,et al.  Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients , 2017, Journal of Nuclear Cardiology.

[21]  Piotr J Slomka,et al.  Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy , 2018, Journal of Nuclear Cardiology.

[22]  Michael A. King,et al.  Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion Imaging , 2019, IEEE Transactions on Medical Imaging.