Design of Current Sensor for Medium Frequency Operation

The paper proposes design procedure of several types of current sensors. The winding design is analyzed regarding its impact on operational characteristics and evaluated for preferred application. The paper also discusses the measurement results and given frequency characteristic and quality factors of the laboratory prototypes.

[1]  Eddy So,et al.  Compact Wideband High-Current ($\geq$ 1000 A) Multistage Current Transformers for Precise Measurements of Current Harmonics , 2007, IEEE Transactions on Instrumentation and Measurement.

[2]  M. Frivaldsky,et al.  Design and simulation of multi-element resonant LCTLC converter with HF transformer , 2014, 2014 ELEKTRO.

[3]  M. Frivaldsky,et al.  A review of multi-elements resonant converters topologies , 2014, 2014 ELEKTRO.

[4]  J. Kaňuch,et al.  The Device to Measuring of the Load Angle for Salient-Pole Synchronous Machine in Education Laboratory , 2018 .

[5]  Marian K. Kazimierczuk,et al.  Bandwidth of Current Transformers , 2009, IEEE Transactions on Instrumentation and Measurement.

[6]  V. Rada,et al.  Calibration of an instrument current transformer at a ratio of 20 kA/5 A , 2012, 2012 Conference on Precision electromagnetic Measurements.

[7]  Petr Bernat,et al.  Adjustment of pull characteristics of lever magnet with variable reluctance , 2017, 2017 18th International Scientific Conference on Electric Power Engineering (EPE).

[8]  Pavol Spanik,et al.  Measurement of swtitching losses in power transistor structure , 2008 .

[9]  A. V. Bessolitsyn,et al.  Experimental study of current error of up to 50 hz current-measuring transformer , 2017, 2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM).

[10]  C. A. Platero,et al.  Testing of non-toroidal shape primary pass-through current transformer for electrical machine monitoring and protection , 2018, 2018 IEEE International Conference on Industrial Technology (ICIT).

[11]  M.G. Wath,et al.  Error compensation method for current transformer , 2016, 2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES).

[12]  Yi Wang,et al.  Study of current transformer calibrating system based on equivalent model , 2012, IEEE 10th International Conference on Industrial Informatics.

[13]  J. Smajic,et al.  Numerical Computation of Ohmic and Eddy-Current Winding Losses of Converter Transformers Including Higher Harmonics of Load Current , 2012, IEEE Transactions on Magnetics.

[14]  Valéria Hrabovcová,et al.  Design of Rotating Electrical Machines , 2009 .

[15]  Vladimir Kindl,et al.  Current Sensor with low inductance , 2019, 2019 20th International Scientific Conference on Electric Power Engineering (EPE).

[16]  Michal Kaczmarek Operation of inductive protective current transformer in condition of distorted current transformation , 2015, 2015 Modern Electric Power Systems (MEPS).

[17]  Michal Kaczmarek,et al.  The influence of the method of winding construction on metrological properties of current transformers designed for systems of monitoring of power quality , 2009, 2009 10th International Conference on Electrical Power Quality and Utilisation.