THE HEMALOG D WHITE CELL DIFFERENTIAL SYSTEM

The Hemalog D system performs automated differential white cell counts utilizing principles of cytochemistry, electro-optical measurement and signal logic processing. Using 0.4 ml of anticoagulated whole blood and an automated continuous flow staining technique, the system is designed to process a new sample each minute. The decision logic classifies individual cells by size and intensity of staining as they flow through detectors designed to measure light loss and light scattering simultaneously. With this system, 10,000 cells/ sample are classified in less than 1 min. Alcian Blue identifies basophils when used in the presence of quaternary ammonium salts and other counterions. Monocytes are the only cells stained in an esterase method using α-naphthol butyrate at pH 6.1 with hexazonium pararosanilin as coupler. This unstable diazonium is produced on stream continuously from stable components. Size and peroxidase staining serve to classify the remaining cells. Lymphocytes and large mononuclear cells are unstained, neutrophils have moderate peroxidase activity, while eosinophils stain very strongly. Threshold detection logic for light scattering and absorption differentiate the neutrophils, eosinophils and lymphocytes. The distribution of peroxidase activity in neutrophils serves as an index of maturity of these cells. The clinical evaluation of this index is reported elsewhere. Results are reported as percentage and as cells per cubic millimeter. A total white blood cell count is also reported and the pattern of cell measurements for 10,000 cells is provided as a picture with diagnostic information content. Advantages of this system in rapid screening result from improved precision of automation, the processing of large numbers of cells and the saving of labor. Precision also makes the acquisition of sequential data on single patients more meaningful and diagnostically valuable.

[1]  H. Gilbert,et al.  Basophil counting with a new staining method using alcian blue. , 1975, Blood.

[2]  G. Castoldi,et al.  Consecutive cytochemical staining for the analysis of the blastic population in the acute phase of chronic myeloid leukemia. , 1975, Biomedicine / [publiee pour l'A.A.I.C.I.G.].

[3]  L Ornstein,et al.  SPECTRAL MATCHING OF CLASSICAL CYTOCHEMISTRY TO AUTOMATED CYTOLOGY , 1974, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[4]  P. Leaverton,et al.  Factors affecting manual white cell differential counts. , 1973, The American journal of medical technology.

[5]  A. Saunders Development of automation of differential leukocyte counts by use of cytochemistry. , 1972, Clinical chemistry.

[6]  G. Brecher,et al.  Instrumentation and automation in clinical hematology. , 1971, Progress in hematology.

[7]  P. Nakane,et al.  SIMULTANEOUS LOCALIZATION OF MULTIPLE TISSUE ANTIGENS USING THE PEROXIDASE-LABELED ANTIBODY METHOD: A STUDY ON PITUITARY GLANDS OF THE RAT , 1968, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[8]  H. Braunsteiner,et al.  [The origin of monocytes]. , 1968, Wiener Zeitschrift fur innere Medizin und ihre Grenzgebiete.

[9]  A. Saunders HISTOCHEMICAL IDENTIFICATION OF ACID MUCOPOLYSACCHARIDES WITH ACRIDINE ORANGE , 1964, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[10]  Clinical Hematology , 1962 .

[11]  A. George The metabolic basis of inherited disease , 1961 .

[12]  S. Schiller,et al.  A method for the separation of acid mucopolysaccharides: its application to the isolation of heparin from the skin of rats. , 1961, The Journal of biological chemistry.

[13]  J. Scott Aliphatic ammonium salts in the assay of acidic polysaccharides from tissues. , 2006, Methods of biochemical analysis.

[14]  J. Miale Laboratory Medicine: Hematology , 1959 .