Accurate vessel width measurement from fundus photographs: a new concept.

Accurate determination of retinal vessel width measurement is important in the study of the haemodynamic changes that accompany various physiological and pathological states. Currently the width at the half height of the transmittance and densitometry profiles are used as a measure of retinal vessel width. A consistent phenomenon of two 'kick points' on the slopes of the transmittance and densitometry profiles near the base, has been observed. In this study, mathematical models have been formulated to describe the characteristic curves of the transmittance and the densitometry profiles. They demonstrate the kick points being coincident with the edges of the blood column. The horizontal distance across the kick points would therefore indicate the actual blood column width. To evaluate this hypothesis, blood was infused through two lengths of plastic tubing of known diameters, and photographed. In comparison with the known diameters, the half height underestimated the blood column width by 7.33% and 6.46%, while the kick point method slightly overestimated it by 1.40% and 0.34%. These techniques were applied to monochromatic fundus photographs. In comparison with the kick point method, the half height underestimated the blood column width in veins by 16.67% and in arteries by 15.86%. The characteristics of the kick points and their practicality have been discussed. The kick point method may provide the most accurate measurement of vessel width possible from these profiles.

[1]  R. Flower,et al.  The effect of blood on ocular fundus reflectance and determination of some optical properties of retinal blood vessels. , 1978, Investigative ophthalmology & visual science.

[2]  B. Petrig,et al.  Altered retinal vascular response to 100% oxygen breathing in diabetes mellitus. , 1984, Ophthalmology.

[3]  C E Krakau,et al.  SOME ESSENTIAL OPTICAL FEATURES OF THE ZEISS FUNDUS CAMERA , 1977, Acta ophthalmologica.

[4]  H. Keen,et al.  Responses of the retinal circulation to systemic autonomic stimulation in diabetes mellitus , 1989, Eye.

[5]  M. Reim,et al.  Retinal circulation times in diabetes mellitus type 1. , 1991, The British journal of ophthalmology.

[6]  K. Myhre,et al.  Fundus photography of width and intensity profiles of the blood column and the light reflex in retinal vessels , 1986 .

[7]  L. Sandvik,et al.  The light reflex in retinal vessels and its relation to age and systemic blood pressure , 1987, Acta ophthalmologica.

[8]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[9]  C. Bulpitt,et al.  The marginal plasma zone in the retinal microcirculation. , 1970, Cardiovascular research.

[10]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[11]  A C Dornhorst,et al.  Review of Medical Physiology. , 1966 .

[12]  Oddbjørn Engvold,et al.  Microphotometry of the blood column and the light streak on retinal vessels in fundus photographs , 1986 .

[13]  D. Hatchell,et al.  Measurement of retinal blood vessel width using computerized image analysis. , 1988, Investigative ophthalmology & visual science.

[14]  Bradley E. Copeland,et al.  Spectrophotometry of Haemoglobin Derivatives , 1971 .

[15]  C E Riva,et al.  Bidirectional LDV system for absolute measurement of blood speed in retinal vessels. , 1979, Applied optics.

[16]  R C Pruett,et al.  Monochromatic ophthalmoscopy and fundus photography. The normal fundus. , 1977, Archives of ophthalmology.

[17]  O. Brinchmann‐Hansen,et al.  Reliable measurements from fundus photographs in the presence of focusing errors. , 1989, Investigative ophthalmology & visual science.