Relation between plaque type and dissections at the edges after stent implantation: an optical coherence tomography study.

BACKGROUND Stent implantation can create vessel damage such as edge dissections. The objectives were i) to evaluate the frequency of edge dissections after stenting visible by intracoronary optical coherence tomography (OCT) in comparison with angiography. ii) to assess with OCT the plaque type left at the stent edges after implantation, and iii) to study whether there is an association between plaque type and dissections at stent edges. METHODS Seventy-three consecutive patients (80 vessels) with OCT post-stent implantation were included in the study. By OCT, plaque type at stent edges and presence of edge dissection were assessed. Angiograms were analyzed by two independent observers to assess the presence of edge dissections. RESULTS Distal and proximal edges were visible by OCT in 72/80 and 45/80 vessels respectively. OCT and angiography agreed in the detection of 7 dissections at distal edge (κ=0.32) and 1 dissection at proximal edge (κ=0.22). Plaque type at distal edge was: fibrotic 55.6%, fibrocalcific 22.2%, fibroatheroma 15.3% and thin-cap fibroatheroma (TCFA) 6.9%. At proximal edge plaque type was: fibrotic 31.1%, fibrocalcific 33.3%, fibroatheroma 28.9% and TCFA 6.7%. In the distal edge, presence of edge dissection was significantly more frequent when the plaque type at the edge was fibrocalcific (43.8%) or lipid rich (37.5%) than when the plaque was fibrous (10%) p=0.009. CONCLUSIONS OCT showed higher sensitivity compared to angiography for the identification of edge dissections. A high proportion of patients showed lipid-rich plaques at stent edges. Plaque type at the stent edges has impact on the presence of edge dissections.

[1]  J. Tobis,et al.  Outcome of nonobstructive residual dissections detected by intravascular ultrasound following percutaneous coronary intervention. , 2002, The American journal of cardiology.

[2]  S. Schroeder,et al.  The impact of untreated coronary dissections on acute and long-term outcome after intravascular ultrasound guided PTCA. , 2000, European heart journal.

[3]  D. Kang,et al.  Long-term outcomes of minor dissection at the edge of stents detected with intravascular ultrasound. , 2000, The American journal of cardiology.

[4]  Renu Virmani,et al.  Pathological Mechanisms of Fatal Late Coronary Stent Thrombosis in Humans , 2003, Circulation.

[5]  P. Fitzgerald,et al.  Acute coronary closure after stenting: a lesson from intravascular ultrasound. , 1999, International journal of cardiovascular interventions.

[6]  R. Virmani,et al.  Pathology of acute and chronic coronary stenting in humans. , 1999, Circulation.

[7]  N. Weissman,et al.  Natural history of intravascular ultrasound-detected edge dissections from coronary stent deployment. , 2000, American heart journal.

[8]  E. Halpern,et al.  Characterization of Human Atherosclerosis by Optical Coherence Tomography , 2002, Circulation.

[9]  Jagat Narula,et al.  Imaging vulnerable plaque by ultrasound. , 2006, Journal of the American College of Cardiology.

[10]  G. Stone,et al.  An integrated TAXUS IV, V, and VI intravascular ultrasound analysis of the predictors of edge restenosis after bare metal or paclitaxel-eluting stents. , 2009, The American journal of cardiology.

[11]  Patrick W Serruys,et al.  In vivo assessment of high-risk coronary plaques at bifurcations with combined intravascular ultrasound and optical coherence tomography. , 2009, JACC. Cardiovascular imaging.

[12]  Renu Virmani,et al.  Experimental evaluation of a short transitional edge protection balloon for intracoronary stent deployment , 2000, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[13]  A. Coats,et al.  Ethical authorship and publishing. , 2009, International journal of cardiology.

[14]  Patrick W Serruys,et al.  Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherenc , 2009, JACC. Cardiovascular interventions.

[15]  Y. Neishi,et al.  Measurement of the thickness of the fibrous cap by optical coherence tomography. , 2006, American heart journal.

[16]  R. Whitbourn,et al.  Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting Stents: Serial Intravascular Ultrasound Analysis From the TAXUS II Trial , 2004, Circulation.

[17]  E. Regar,et al.  Optical coherence tomography: clinical applications and the evaluation of DES. , 2008, Minerva cardioangiologica.

[18]  E. Halpern,et al.  Evaluation of intracoronary stenting by intravascular optical coherence tomography , 2003, Heart.

[19]  P. Serruys,et al.  Diagnosis and treatment of coronary vulnerable plaques , 2008, Expert review of cardiovascular therapy.

[20]  Patrick W Serruys,et al.  Coronary-artery stents. , 2006, The New England journal of medicine.

[21]  N. Weissman,et al.  Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment. , 2007, The American journal of cardiology.

[22]  Francesco Prati,et al.  A multicentre evaluation of the safety of intracoronary optical coherence tomography. , 2009, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[23]  Patrick W Serruys,et al.  Multi-modality intra-coronary plaque characterization: a pilot study. , 2010, International journal of cardiology.

[24]  Patrick W Serruys,et al.  Assessment of culprit and remote coronary narrowings using optical coherence tomography with long-term outcomes. , 2008, The American journal of cardiology.

[25]  Renu Virmani,et al.  Vulnerable plaque: the pathology of unstable coronary lesions. , 2002, Journal of interventional cardiology.

[26]  Patrick W Serruys,et al.  Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy , 2004, The Lancet.

[27]  Evelyn Regar,et al.  Novelties in cardiac imaging--optical coherence tomography (OCT). , 2008, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[28]  E. Tuzcu,et al.  Intravascular ultrasound assessment of the prevalence and causes of angiographic "haziness" following high-pressure coronary stenting. , 1997, The American journal of cardiology.

[29]  P. Fitzgerald,et al.  Detailed intravascular ultrasound analysis of Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy stent in de novo coronary lesions (results from the ENDEAVOR II trial). , 2007, The American journal of cardiology.

[30]  P. Fitzgerald,et al.  Vessel tearing at the edge of intracoronary stents detected with intravascular ultrasound imaging. , 1997, Catheterization and cardiovascular diagnosis.

[31]  P. Serruys,et al.  Characterization of edge effects with paclitaxel-eluting stents using serial intravascular ultrasound radiofrequency data analysis: the BETAX (BEside TAXus) Study. , 2008, Revista espanola de cardiologia.

[32]  R E Vlietstra,et al.  Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. , 1992, Journal of the American College of Cardiology.