Temporal segmentation and multiple-source analysis of short-latency median nerve SEPs.

Short-latency (10-50 ms) median nerve somatosensory evoked potentials (SEPs) from four normal subjects were analysed by means of temporal segmentation techniques and source derivation methods. In each case the responses were recorded using 32 electrodes. Dipolar optimization was carried out with a time-varying technique, using three different approaches: regional source estimation, spherical source estimation (one radial and one tangential component), and multiple dipolar approach. This was to assess the relative influence on the dipolar solution of the different optimization techniques. The effect of the different number of channels in the estimation procedures has been also investigated. The methods of optimization are crucial, particularly for the orientation of P22. In all cases the source location estimated with the 32-electrode montage was shifted towards the centre of the spheres.

[1]  D F Stegeman,et al.  Dipole modelling of median nerve SEPs in normal subjects and patients with small subcortical infarcts. , 1992, Electroencephalography and clinical neurophysiology.

[2]  W W Sutherling,et al.  Spatiotemporal modeling of cerebral evoked magnetic fields to median nerve stimulation. , 1991, Electroencephalography and clinical neurophysiology.

[3]  H Spekreijse,et al.  The extrastriate generators of the EP to checkerboard onset. A source localization approach. , 1991, Electroencephalography and clinical neurophysiology.

[4]  W W Sutherling,et al.  Functional anatomy of human hand sensorimotor cortex from spatiotemporal analysis of electrocorticography. , 1991, Electroencephalography and clinical neurophysiology.

[5]  F Grandori,et al.  Individual versus averaged data in the analysis of auditory evoked electrical potentials. , 1991, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[6]  P. Ravazzani,et al.  Source analysis of auditory evoked middle-latency responses. , 1991, Acta oto-laryngologica. Supplementum.

[7]  J. D. Munck The estimation of time varying dipoles on the basis of evoked potentials. , 1990 .

[8]  P. Ravazzani,et al.  Field analysis of middle-latency auditory-evoked electric and magnetic responses , 1990 .

[9]  M. Scherg,et al.  A Source Analysis of the Late Human Auditory Evoked Potentials , 1989, Journal of Cognitive Neuroscience.

[10]  C. C. Wood,et al.  Human cortical potentials evoked by stimulation of the median nerve. I. Cytoarchitectonic areas generating short-latency activity. , 1989, Journal of neurophysiology.

[11]  J. D. Munck The potential distribution in a layered anisotropic spheroidal volume conductor , 1988 .

[12]  H. Spekreijse,et al.  Principal components analysis for source localization of VEPs in man , 1987, Vision Research.

[13]  J E Desmedt,et al.  Bit-mapped color imaging of human evoked potentials with reference to the N20, P22, P27 and N30 somatosensory responses. , 1987, Electroencephalography and clinical neurophysiology.

[14]  Ferdinando Grandori,et al.  Field analysis of auditory evoked brainstem potentials , 1986, Hearing Research.

[15]  F Mauguiere,et al.  Separate generators with distinct orientations for N20 and P22 somatosensory evoked potentials to finger stimulation? , 1986, Electroencephalography and clinical neurophysiology.

[16]  C C Wood,et al.  Electrical sources in human somatosensory cortex: identification by combined magnetic and potential recordings. , 1985, Science.

[17]  M. Scherg,et al.  Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model. , 1985, Electroencephalography and clinical neurophysiology.

[18]  F. Grandori Dipole localization methods (DLM) and auditory evoked brainstem potentials. , 1984, Revue de laryngologie - otologie - rhinologie.

[19]  F Mauguière,et al.  Astereognosis and dissociated loss of frontal or parietal components of somatosensory evoked potentials in hemispheric lesions. Detailed correlations with clinical signs and computerized tomographic scanning. , 1983, Brain : a journal of neurology.

[20]  G. Cheron,et al.  Non-cephalic reference recording of early somatosensory potentials to finger stimulation in adult or aging normal man: differentiation of widespread N18 and contralateral N20 from the prerolandic P22 and N30 components. , 1981, Electroencephalography and clinical neurophysiology.

[21]  J. P. Ary,et al.  Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses , 1981, IEEE Transactions on Biomedical Engineering.

[22]  G Cheron,et al.  Somatosensory evoked potentials to finger stimulation in healthy octogenarians and in young adults: wave forms, scalp topography and transit times of parietal and frontal components. , 1980, Electroencephalography and clinical neurophysiology.

[23]  D. Lehmann,et al.  Reference-free identification of components of checkerboard-evoked multichannel potential fields. , 1980, Electroencephalography and clinical neurophysiology.