Comparison Between Chinese and Eurocode Code Related to Shear Force Resistance for Non-Web-Reinforced Beam

This paper introduces the factors which affect the shear force resistance of beams without web reinforcement,analyzes the formula for calculating the shear strength and the minimum shear reinforcement ratio of Chinese and European standard。The comparisons indicated that the results more or less with the Chinese and European standards under lower concrete strengh,but higher concrete strengh, the Chinese reliability index is lower than the European.