Over-exposure correction in knee cone-beam CT imaging with automatic exposure control using a partial low dose scan

C-arm-based cone-beam CT (CBCT) systems with flat-panel detectors are suitable for diagnostic knee imaging due to their potentially flexible selection of CT trajectories and wide volumetric beam coverage. In knee CT imaging, over-exposure artifacts can occur because of limitations in the dynamic range of the flat panel detectors present on most CBCT systems. We developed a straightforward but effective method for correction and detection of over-exposure for an Automatic Exposure Control (AEC)-enabled standard knee scan incorporating a prior low dose scan. The radiation dose associated with the low dose scan was negligible (0.0042mSv, 2.8% increase) which was enabled by partially sampling the projection images considering the geometry of the knees and lowering the dose further to be able to just see the skin-air interface. We combined the line integrals from the AEC and low dose scans after detecting over-exposed regions by comparing the line profiles of the two scans detector row-wise. The combined line integrals were reconstructed into a volumetric image using filtered back projection. We evaluated our method using in vivo human subject knee data. The proposed method effectively corrected and detected over-exposure, and thus recovered the visibility of exterior tissues (e.g., the shape and density of the patella, and the patellar tendon), incorporating a prior low dose scan with a negligible increase in radiation exposure.

[1]  M. Tapiovaara,et al.  PCXMC. A PC-based Monte Carlo program for calculating patient doses in medical x-ray examinations , 1997 .

[2]  J Hornegger,et al.  Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT. , 2015, Medical physics.

[3]  Andreas Keil,et al.  Analysis of vertical and horizontal circular C-arm trajectories , 2011, Medical Imaging.

[4]  Rebecca Fahrig,et al.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment. , 2014, Medical physics.

[5]  Michael Knaup,et al.  Digitization and visibility issues in flat detector CT: A simulation study , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[6]  Richard E. Colbeth,et al.  Multiple-gain-ranging readout method to extend the dynamic range of amorphous silicon flat-panel imagers , 2004, SPIE Medical Imaging.

[7]  Norbert J Pelc,et al.  An algorithm to estimate the object support in truncated images. , 2014, Medical physics.

[8]  Andreas K. Maier,et al.  Over-Exposure Correction in CT Using Optimization-Based Multiple Cylinder Fitting , 2015, Bildverarbeitung für die Medizin.

[9]  Andreas Maier,et al.  Region-of-interest reconstruction on medical C-arms with the ATRACT algorithm , 2012, Medical Imaging.

[10]  J. Hsieh,et al.  A novel reconstruction algorithm to extend the CT scan field-of-view. , 2004, Medical physics.

[11]  Rebecca Fahrig,et al.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization. , 2013, Medical physics.