Quantitative reconstruction for myocardial perfusion SPECT: an efficient approach by depth-dependent deconvolution and matrix rotation.

An efficient reconstruction method for myocardial perfusion single-photon emission computed tomography (SPECT) has been developed which compensates simultaneously for attenuation, scatter, and resolution variation. The scattered photons in the primary-energy-window measurements are approximately removed by subtracting the weighted scatter-energy-window samples. The resolution variation is corrected by deconvolving the subtracted data with the detector-response kernel in frequency space using the depth-dependent frequency relation. The attenuated photons are compensated by recursively tracing the attenuation factors through the object-specific attenuation map. An experimental chest phantom with defects inside myocardium was used to test the method. The attenuation map of the phantom was reconstructed from transmission scans using a flat external source and a high-resolution parallel-hole collimator of a single-detector system. The detector-response kernel was approximated from measurements of a point source in air at several depths from the collimator surface. The emission data were acquired by the same detector setting. A computer simulation using similar protocols as in the experiment was performed. Both the simulation and experiment showed significant improvement in quantification with the proposed method, as compared to the conventional filtered-backprojection technique. The quantitative gain by the additional deconvolution was demonstrated. The computation time was less than 20 min on a HP/730 desktop computer for reconstruction of a 1282 x 64 array from 128 projections of 128 x 64 samples.

[1]  S. Strother,et al.  Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography. , 1993, Medical physics.

[2]  Matt A. King,et al.  A dual-photopeak window method for scatter correction. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Ronald J. Jaszczak,et al.  Analysis of SPECT including Scatter and Attenuation Using Sophisticated Monte Carlo Modeling Methods , 1982, IEEE Transactions on Nuclear Science.

[4]  Ronald J. Jaszczak,et al.  Reconstruction of SPECT images using generalized matrix inverses , 1992, IEEE Trans. Medical Imaging.

[5]  Thomas Bortfeld,et al.  The exponential radon transform and projection filtering in radiotherapy planning , 1995, Int. J. Imaging Syst. Technol..

[6]  R. Jaszczak,et al.  Improved SPECT quantification using compensation for scattered photons. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  T. M. Peters Algorithms for Fast Back- and Re-Projection in Computed Tomography , 1981 .

[8]  T R Miller,et al.  Rapidly converging iterative reconstruction algorithms in single-photon emission computed tomography. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  S. Bellini,et al.  Compensation of tissue absorption in emission tomography , 1979 .

[10]  Robert M. Lewitt,et al.  Fourier Method For Correction Of Depth-Dependent Collimator Blurring , 1989, Medical Imaging.

[11]  F D Thomas,et al.  Phantom study of breast tissue attenuation in myocardial imaging. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  J R Perry,et al.  Correction of nonuniform attenuation in cardiac SPECT imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  B.M.W. Tsui,et al.  Three-dimensional Iterative Reconstruction Algorithms With Attenuation And Geometric Point Response Correction , 1990, 1990 IEEE Nuclear Science Symposium Conference Record.

[14]  H H Barrett,et al.  Null functions and eigenfunctions: tools for the analysis of imaging systems. , 1991, Progress in clinical and biological research.

[15]  Jorge Llacer,et al.  Matrix-Based Image Reconstruction Methods for Tomography , 1985, IEEE Transactions on Nuclear Science.

[16]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[17]  Michael A. King,et al.  Quantitative SPECT imaging: compensation for nonuniform attenuation, scatter, and detector divergence , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[18]  R. Jaszczak,et al.  Evaluation of projection pixel-dependent and pixel-independent scatter correction in SPECT , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[19]  N. Shuke,et al.  Myocardial perfusion imaging and dynamic analysis with technetium-99m tetrofosmin. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  Z. Liang An efficient three-dimensional unified projector-backprojector for SPECT reconstruction , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[21]  Zhengrong Liang,et al.  Reconstruction Of Object-specific Attenuation Map For Quantitative SPECT , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[22]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .

[23]  Grant T. Gullberg,et al.  Users Manual: Donner Algorithms for Reconstruction Tomography , 1977 .

[24]  Koichi Ogawa,et al.  Correction Of Collimator Aperture Using A Shift-Variant Deconvolution Filter In Gamma Camera Emission CT , 1988, Medical Imaging.

[25]  R J Jaszczak,et al.  Cardiac phantom evaluation of simultaneously acquired dual-isotope rest thallium-201/stress technetium-99m SPECT images. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  Ronald J. Jaszczak,et al.  Reprojection and backprojection in SPECT image reconstruction , 1989, Proceedings. IEEE Energy and Information Technologies in the Southeast'.

[27]  C E Floyd,et al.  Inverse Monte Carlo as a unified reconstruction algorithm for ECT. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[28]  J R Galt,et al.  Effects of myocardial wall thickness on SPECT quantification. , 1990, IEEE transactions on medical imaging.

[29]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[30]  H Kiat,et al.  Technetium 99m sestamibi in the assessment of chronic coronary artery disease. , 1991, Seminars in nuclear medicine.

[31]  J. Douglas Faires,et al.  Numerical Analysis , 1981 .

[32]  D. Berman,et al.  Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[33]  K. Ogawa,et al.  A practical method for position-dependent Compton-scatter correction in single photon emission CT. , 1991, IEEE transactions on medical imaging.

[34]  G. Gullberg THE ATTENUATED RADON TRANSFORM: THEORY AND APPLICATION IN MEDICINE AND BIOLOGY , 1979 .

[35]  Michael A. King,et al.  Non-iterative compensation for the distance-dependent detector response and photon attenuation in SPECT imaging , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[36]  T. Turkington,et al.  Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions. , 1992, Physics in medicine and biology.

[37]  G.T. Gullberg,et al.  Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[38]  Z. Liang,et al.  Compensation for attenuation, scatter, and detector response in SPECT reconstruction via iterative FBP methods. , 1993, Medical physics.