Application of a continuous-wave tunable erbium-doped fiber laser to molecular spectroscopy in the near infrared

Development of a continuous-wave tunable fiber laser-based spectrometer for applied spectroscopy is reported. Wide wavelength tunability of an erbium-doped fiber laser (EDFL) was investigated in the near-infrared region of 1543–1601 nm. Continuous mode-hop free fine frequency tuning has been accomplished by temperature tuning in conjunction with mechanical tuning. The overall spectroscopic performance of the EDFL was evaluated in terms of frequency tunability along with its suitability for molecular spectroscopy. High-resolution absorption spectra of acetylene (C2H2) were recorded near 1544 nm with a minimum measurable absorption coefficient of about 3.5×10-7 cm-1/Hz1/2 for direct absorption spectroscopy associated with a 100-m long multipass cell. Detections of C2H2 at different concentration levels were performed as well with high dynamic detection range varying from 100% purity to sub ppmv using cavity ring down spectroscopy. A 3σ-detection-limited minimum detectable concentration (MDC) of 400 ppbv has been obtained by using the transition line Pe(22) of the ν1+ν3+ν51(Πg)-ν51(Πu) hot band near 1543.92 nm with a detection bandwidth of 2.3 Hz. This corresponds to a minimum detectable absorption coefficient of 6.6×10-11 cm-1/Hz1/2. The sensitivity limit could be further improved by almost one order of magnitude (down to ∼60 ppbv) by use of the Pe(27) line of the ν1+ν3(Σu+)-0(Σg+)combination band near 1543.68 nm.

[1]  B. D. Green,et al.  Handheld, battery-powered near-IR TDL sensor for stand-off detection of gas and vapor plumes , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[2]  Antoine Bellemare,et al.  Continuous-wave silica-based erbium-doped fibre lasers , 2003 .

[3]  Daniele Romanini,et al.  High-sensitivity CW-cavity ringdown spectroscopy of 12CO2 near 1.5 μm , 2005 .

[4]  T. Morse,et al.  Demonstration of a rapidly strain tuned Er3+-doped fiber laser for sensitive gas detection. , 1999, Applied optics.

[5]  P. De Natale,et al.  Remote sensing of volcanic gases with a DFB-laser-based fiber spectrometer , 2000 .

[6]  High-speed vertical-cavity surface-emitting laser (VCSEL) absorption spectroscopy of ammonia (NH3) near 1.54 μm , 2003 .

[7]  P. De Natale,et al.  A 3.5-mW continuous-wave difference-frequency source around 3 μm for sub-Doppler molecular spectroscopy , 2005, EQEC '05. European Quantum Electronics Conference, 2005..

[8]  S. Mikhailenko,et al.  High sensitivity CW-cavity ring down spectroscopy of water in the region of the 1.5 μm atmospheric window , 2004 .

[9]  Yabai He,et al.  Rapid measurement of cavity ringdown absorption spectra with a swept-frequency laser , 2004 .

[10]  M. Allen,et al.  Measurements of CO, CO2, OH, and H2O in room-temperature and combustion gases by use of a broadly current-tuned multisection InGaAsP diode laser. , 1999, Applied optics.

[11]  Francesco S. Pavone,et al.  Simultaneous detection of CO and CO2 using a semiconductor DFB diode laser at 1.578 μm , 1997 .

[12]  Daniele Romanini,et al.  Two schemes for trace detection using cavity ringdown spectroscopy , 2004 .

[13]  Khosrow Namjou,et al.  Nitric oxide breath testing by tunable-diode laser absorption spectroscopy: application in monitoring respiratory inflammation. , 2002, Applied optics.

[14]  J. B. Paul,et al.  Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy , 2002 .

[15]  Charles C. Harb,et al.  A laser-locked cavity ring-down spectrometer employing an analog detection scheme , 2000 .

[16]  P. Werle,et al.  Near-infrared trace-gas sensors based on room-temperature diode lasers , 1998 .

[17]  Damien Weidmann,et al.  Application of a widely electrically tunable diode laser to chemical gas sensing with quartz-enhanced photoacoustic spectroscopy. , 2004, Optics letters.