Design and performance of a solar-powered heating and cooling system using silica gel/water adsorption chiller

Abstract In this paper, a solar-powered compound system for heating and cooling was designed and constructed in a golf course in Taiwan. An integrated, two-bed, closed-type adsorption chiller was developed in the Industrial Technology Research Institute in Taiwan. Plate fin and tube heat exchangers were adopted as an adsorber and evaporator/condenser. Some test runs have been conducted in the laboratory. Under the test conditions of 80 °C hot water, 30 °C cooling water, and 14 °C chilled water inlet temperatures, a cooling power of 9 kW and a COP (coefficient of performance for cooling) of 0.37 can be achieved. It has provided a SCP (specific cooling power) of about 72 W/(kg adsorbent). Some field tests have been performed from July to October 2006 for providing air-conditioning and hot water. The efficiency of the collector field lies in 18.5–32.4%, with an average value of 27.3%. The daily average COP of the adsorption chiller lies in 33.8–49.7%, with an average COP of 40.3% and an average cooling power of 7.79 kW. A typical daily operation shows that the efficiency of the solar heating system, the adsorption cooling and the entirely solar cooling system is 28.4%, 45.2%, and 12.8%, respectively.

[1]  Takao Kashiwagi,et al.  Parametric study of a silica gel-water adsorption refrigeration cycle -- The influence of thermal capacitance and heat exchanger UA-values on cooling capacity, power density, and COP , 1997 .

[2]  Yong Tae Kang,et al.  Heat exchanger design effect on the system performance of silica gel adsorption refrigeration systems , 2000 .

[3]  Ruzhu Wang,et al.  An efficient solar-powered adsorption chiller and its application in low-temperature grain storage , 2007 .

[4]  Hui Tong Chua,et al.  Modeling of a two-bed silica gel-water adsorption chiller , 2004 .

[5]  Takao Kashiwagi,et al.  Modeling the performance of two-bed, sillica gel-water adsorption chillers , 1999 .

[6]  M. Suzuki,et al.  Simultaneous Transport of Heat and Adsorbate in Closed Type Adsorption Cooling System Utilizing Solar Heat , 1986 .

[7]  Takao Kashiwagi,et al.  Experimental investigation of a silica gel-water adsorption refrigeration cycle -- The influence of operating conditions on cooling output and COP , 1995 .

[8]  M. Fischer,et al.  Adsorption cooling system for cold storage using methanol/silicagel , 1998 .

[9]  Ruzhu Wang,et al.  Experimental investigation of a solar adsorption chiller used for grain depot cooling , 2006 .

[10]  W.-S. Chang,et al.  Experimental study of a solid adsorption cooling system using flat-tube heat exchangers as adsorption bed , 2007 .

[11]  Takao Kashiwagi,et al.  Computer simulation of a silica gel-water adsorption refrigeration cycle - the influence of operating conditions on cooling output and COP , 1995 .

[12]  Takao Kashiwagi,et al.  Experimental investigation of an advanced adsorption refrigeration cycle , 1997 .