Interferences in immunoassay--still a threat.

Few things in life are perfect, and unfortunately this also applies to medical diagnostic procedures such as clinical laboratory testing. In spite of the careful efforts of the developers and manufacturers of clinical laboratory tests and the vigilance of the laboratory staffs that perform the testing, most if not all tests are, on occasion, subject to interferences that lead to false-positive or false-negative results (1)(2). Immunoassay tests are no exception. Recent literature has documented false-positive or false-negative results in immunoassays or reports investigations of specific interferences (3)(4). Sources of interferences include plasma (5), serum proteins (e.g., rheumatoid factor, binding proteins) (6)(7), heterophile and anti-animal antibodies (2)(8)(9), drugs and drug metabolites (10)(11), hemolysis (12), agar (13), and cross-reacting substances (14). In most cases, a significant interference is recognized and flagged, but sometimes the interference is unsuspected and undetected. There now is adequate evidence that bad …

[1]  P. Thomopoulos,et al.  False hyperthyrotropinemia induced by heterophilic antibodies against rabbit serum. , 1981, The Journal of clinical endocrinology and metabolism.

[2]  L. Berglund,et al.  Heterophilic Antibodies Against Rabbit Serum Causing Falsely Elevated Gonadotropin Levels , 1989, Acta obstetricia et gynecologica Scandinavica.

[3]  R. Valdes,et al.  Approaches to minimizing interference by cross-reacting molecules in immunoassays. , 1991, Clinical chemistry.

[4]  G. Zehender,et al.  High prevalence of false-negative anti-HTLV type I/II enzyme-linked immunosorbent assay results in HIV type 1-positive patients. , 1997, AIDS research and human retroviruses.

[5]  M. Miller,et al.  False‐Positive Enzyme Immunoassay Test Results for Chlamydia trachomatis Because of Contact of the Collection Swab With Agar , 1998, Sexually transmitted diseases.

[6]  D. Kang,et al.  Urine concentration of biopyrrins: a new marker for oxidative stress in vivo. , 1998, Clinical chemistry.

[7]  R. Granouillet,et al.  Interférence d’IgM monoclonale dans la détermination de la protéine C réactive et de la ferritine par immunonéphélémétrie , 1998 .

[8]  R. Wenk Mechanism of interference by hemolysis in immunoassays and requirements for sample quality. , 1998, Clinical chemistry.

[9]  T. Mencken,et al.  False-positive immunochemical screen for methadone attributable to metabolites of verapamil. , 1998, Clinical chemistry.

[10]  H. H. Sørensen,et al.  Variety in Growth Hormone Determinations due to Use of Different Immunoassays and to the Interference of Growth Hormone-Binding Protein , 1999, Hormone Research in Paediatrics.

[11]  L J Kricka,et al.  Human anti-animal antibody interferences in immunological assays. , 1999, Clinical chemistry.

[12]  A. Dasgupta,et al.  Effect of digoxin fab antibody on the measurement of total and free digitoxin by fluorescence polarization and a new chemiluminescent immunoassay. , 1999, Therapeutic drug monitoring.

[13]  J. Krahn,et al.  High percentage of false positive cardiac troponin I results in patients with rheumatoid factor. , 1999, Clinical biochemistry.

[14]  L. Cole,et al.  False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma. , 1999, Clinical chemistry.

[15]  D. Remick,et al.  Plasma interference in an enzyme-linked immunosorbant assay using a commercial matched antibody pair. , 1999, Immunological investigations.

[16]  C. Selby,et al.  Interference in Immunoassay , 1999, Annals of clinical biochemistry.

[17]  L. Cole,et al.  False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations , 2000, The Lancet.

[18]  L. Rink,et al.  The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs. , 2000, Journal of immunological methods.

[19]  P. Youinou,et al.  False positivity in a cyto-ELISA for anti-endothelial cell antibodies caused by heterophile antibodies to bovine serum proteins. , 2000, Clinical chemistry.

[20]  P Balfe,et al.  False‐negative HIV antibody test results , 2000, Journal of medical virology.

[21]  L. Kohn,et al.  To Err Is Human : Building a Safer Health System , 2007 .

[22]  J. Pfeifer,et al.  An IgM λ antibody to Escherichia coli produces false-positive results in multiple immunometric assays , 2000 .