Expiratory flow limitation detected by forced oscillation and negative expiratory pressure

The within-breath change in reactance (ΔX̄rs) measured by forced oscillation technique (FOT) at 5 Hz reliably detects expiratory flow limitation in chronic obstructive pulmonary disease (COPD). The present study compared this approach to the standard negative expiratory pressure (NEP) method. In total, 21 COPD patients were studied by applying both techniques to the same breath and in 15 patients the measurements were repeated after bronchodilator. For each patient and condition five NEP tests were performed and independently scored by three operators unaware of the FOT results. In 180 tests, FOT classified 53.3% as flow limited. On average, the operators scored 27.6% of tests flow limited and 47.6% non-flow limited, but could not score 24.8%. The methods disagreed in 7.9% of cases; in 78% of these the NEP scores differed between operators. Bronchodilation reduced NEP and ΔX̄rs scores, with only the latter achieving significance. Averaging the operators′ NEP scores, a threshold between 24.6–30.8% of tidal volume being flow limited by NEP produced 94% agreement between methods. In conclusion, when negative expiratory pressure and forced oscillation technique were both available they showed good agreement. As forced oscillation technique is automatic and can measure multiple breaths over long periods, it is suitable for monitoring expiratory flow limitation continuously and identifying patients′ breathing close to the onset of expiratory flow limitation, where intermittent sampling may be unrepresentative.

[1]  A Pedotti,et al.  Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP , 2006, European Respiratory Journal.

[2]  A Pedotti,et al.  Effect of salbutamol on lung function and chest wall volumes at rest and during exercise in COPD , 2005, Thorax.

[3]  P. Calverley,et al.  Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology , 2005, European Respiratory Journal.

[4]  M. Kerkhofs,et al.  Operating characteristics of the negative expiratory pressure technique in predicting obstructive sleep apnoea syndrome in snoring patients , 2004, Thorax.

[5]  D. O’Donnell,et al.  Effect of salmeterol on the ventilatory response to exercise in chronic obstructive pulmonary disease , 2004, European Respiratory Journal.

[6]  B. Make,et al.  Effects of tiotropium on lung hyperinflation, dyspnoea and exercise tolerance in COPD , 2004, European Respiratory Journal.

[7]  W. MacNee,et al.  Standards for the diagnosis and treatment of patients with COPD: a summary of the ATS/ERS position paper , 2004, European Respiratory Journal.

[8]  A Pedotti,et al.  Detection of expiratory flow limitation in COPD using the forced oscillation technique , 2004, European Respiratory Journal.

[9]  A. Buist,et al.  Risk of over-diagnosis of COPD in asymptomatic elderly never-smokers , 2002, European Respiratory Journal.

[10]  L. Pini,et al.  Volume effect and exertional dyspnoea after bronchodilator in patients with COPD with and without expiratory flow limitation at rest , 2002, Thorax.

[11]  F. Portier,et al.  Evidence for expiratory flow limitation of extrathoracic origin in patients with obstructive sleep apnoea , 2002, Thorax.

[12]  P. Calverley,et al.  Alternative methods for assessing bronchodilator reversibility in chronic obstructive pulmonary disease , 2001, Thorax.

[13]  R. Pauwels,et al.  Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary. , 2001, American journal of respiratory and critical care medicine.

[14]  M. Fournier,et al.  Flow limitation and dynamic hyperinflation during exercise in COPD patients after single lung transplantation. , 2000, Chest.

[15]  H. Ghezzo,et al.  Role of inspiratory capacity on exercise tolerance in COPD patients with and without tidal expiratory flow limitation at rest. , 2000, The European respiratory journal.

[16]  T. Similowski,et al.  Effect of negative expiratory pressure on respiratory system flow resistance in awake snorers and nonsnorers. , 1999, Journal of applied physiology.

[17]  T. Similowski,et al.  Dynamic hyperinflation and flow limitation during methacholine-induced bronchoconstriction in asthma. , 1999, The European respiratory journal.

[18]  M. Pichot,et al.  Expiratory flow limitation in stable asthmatic patients during resting breathing. , 1997, American journal of respiratory and critical care medicine.

[19]  M. Cosio,et al.  Detection of expiratory flow limitation during exercise in COPD patients. , 1997, Journal of applied physiology.

[20]  D. Navajas,et al.  Effect of expiratory flow limitation on respiratory mechanical impedance: a model study. , 1996, Journal of applied physiology.

[21]  N. Koulouris,et al.  A simple method to detect expiratory flow limitation during spontaneous breathing. , 1995, The European respiratory journal.

[22]  J E Cotes,et al.  Lung volumes and forced ventilatory flows , 1993, European Respiratory Journal.

[23]  J E Cotes,et al.  Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. , 1993, The European respiratory journal. Supplement.

[24]  P. Roe,et al.  Pulmonary disease , 1991 .

[25]  G Grimby,et al.  Frequency dependence of flow resistance in patients with obstructive lung disease. , 1968, The Journal of clinical investigation.

[26]  J. Mead,et al.  Physical Properties of Human Lungs Measured During Spontaneous Respiration , 1953 .

[27]  A. Baydur,et al.  Extrathoracic expiratory flow limitation in obesity and obstructive and restrictive disorders: effects of increasing negative expiratory pressure. , 2004, Chest.