Continuous colorimetric determination of trace ammonium in seawater with a long-path liquid waveguide capillary cell

An automated method for routine determination of nanomolar ammonium in seawater has been developed using segmented flow analysis coupled with a 2-m-long liquid waveguide capillary cell. Conventional photometric detector and autosampler were modified for this method. The optimal concentrations of the reagents and parameters for the development of indophenol blue are discussed. The method has low detection limit (5 nM), high precision (5% at 10–100 nM) and the advantage of rapid analysis of a large number of samples. The method has been used to examine the distribution of ammonium in Florida Bay and Biscayne Bay. D 2004 Elsevier B.V. All rights reserved.

[1]  L. Solórzano DETERMINATION OF AMMONIA IN NATURAL WATERS BY THE PHENOLHYPOCHLORITE METHOD 1 1 This research was fully supported by U.S. Atomic Energy Commission Contract No. ATS (11‐1) GEN 10, P.A. 20. , 1969 .

[2]  R. Gibbs,et al.  Marine chemistry. , 1976, Science.

[3]  Robert D. Waterbury,et al.  Determination of nanomolar concentrations of nitrite and nitrate in natural waters using long path length absorbance spectroscopy , 1998 .

[4]  B. Irwin,et al.  The kinetics of nitrogen utilization in the oceanic mixed layer: Nitrate and ammonium interactions at nanomolar concentrations , 1996 .

[5]  C. D’Elia,et al.  NUTRITIONAL STUDIES OF TWO RED ALGAE. II. KINETICS OF AMMONIUM AND NITRATE UPTAKE 1, 2 , 1978 .

[6]  H. Hansen,et al.  Determination of nutrients , 2007 .

[7]  D. Karl,et al.  MAGIC : a sensitive and precise method for measuring dissolved phosphorus in aquatic environments , 1992 .

[8]  M. Brzezinski Colorimetric determination of nanomolar concentrations of ammonium in seawater using solvent extraction , 1987 .

[9]  Ronald D. Jones,et al.  Seasonal and long-term trends in the water quality of Florida Bay (1989–1997) , 1999 .

[10]  J. Chi,et al.  Automated analysis of nanomolar concentrations of phosphate in natural waters with liquid waveguide. , 2002, Environmental science & technology.

[11]  F. Millero,et al.  Gas-segmented continuous flow analysis of iron in water with a long liquid waveguide capillary flow cell , 2001 .

[12]  Estimation of the air/sea exchange of ammonia for the North Atlantic Basin , 1996 .

[13]  R. Byrne,et al.  Long pathlength absorbance spectroscopy: trace analysis of Fe(II) using a 4.5m liquid core waveguide , 1997 .

[14]  P. Wheeler,et al.  Ammonium recycling limits nitrate use in the oceanic subarctic Pacific , 1990 .

[15]  A. Bouwman,et al.  A global high‐resolution emission inventory for ammonia , 1997 .

[16]  R. Wanninkhof,et al.  Enhanced new production observed from the diurnal cycle of nitrate in an oligotrophic anticyclonic eddy , 2001 .

[17]  P. Liss,et al.  Analysis of ammonia and methylamines in natural waters by flow injection gas diffusion coupled to ion chromatography , 1995 .

[18]  E. Boyle,et al.  Automated High Resolution Determination of the Trace Elements Iron and Aluminium in the Surface Ocean Using a Towed Fish Coupled to Flow Injection Analysis , 2000 .

[19]  Roger Kerouel,et al.  Determination of ammonia in seawater by the indophenol-blue method: Evaluation of the ICES NUTS I/C 5 questionnaire , 1997 .

[20]  Manfred Ehrhardt,et al.  Methods of seawater analysis , 1999 .

[21]  K. Fanning,et al.  A sensor package for the simultaneous determination of nanomolar concentrations of nitrite, nitrate, and ammonia in seawater by fluorescence detection , 2000 .

[22]  Jia-Zhong Zhang Shipboard automated determination of trace concentrations of nitrite and nitrate in oligotrophic water by gas-segmented continuous flow analysis with a liquid waveguide capillary flow cell , 2000 .

[23]  Roger Kerouel,et al.  Fluorometric determination of ammonia in sea and estuarine waters by direct segmented flow analysis , 1997 .

[24]  Ronald D. Jones An improved fluorescence method for the determination of nanomolar concentrations of ammonium in natural waters , 1991 .

[25]  A. Rees,et al.  Nutrient distributions in an anticyclonic eddy in the northeast Atlantic Ocean, with reference to nanomolar ammonium concentrations , 2001 .

[26]  C. Bower,et al.  A Salicylate–Hypochlorite Method for Determining Ammonia in Seawater , 1980 .

[27]  C. J. Kok,et al.  Re-examination of the determination of ammonium as the indophenol blue complex using salicylate , 1989 .

[28]  James N. Galloway,et al.  Acid deposition: Perspectives in time and space , 1995 .

[29]  Adrian P. Martin,et al.  A Lagrangian SF6 tracer study of an anticyclonic eddy in the North Atlantic: patch evolution, vertical mixing and nutrient supply to the mixed layer , 2001 .

[30]  S. R. Crouch,et al.  Spectrophotometric and kinetics investigation of the Berthelot reaction for the determination of ammonia , 1977 .

[31]  C. Garside,et al.  Determination of submicromolar concentrations of ammonia in natural waters by a standard addition method using a gas-sensing electrode1 , 1978 .

[32]  S. Pai,et al.  pH and buffering capacity problems involved in the determination of ammonia in saline water using the indophenol blue spectrophotometric method , 2001 .