A review of cyclic fatigue testing of nickel-titanium rotary instruments.

INTRODUCTION Fractured rotary nickel-titanium (NiTi) instruments have been classified into those that fail as a result of cyclic flexural fatigue or torsional failure or a combination of both. Clinically, NiTi rotary instruments are subjected to both torsional load and cyclic fatigue, and ongoing research aims to clarify the relative contributions of both factors to instrument separation. METHODS To date, there is no specification or international standard to test cyclic fatigue resistance of endodontic rotary instruments. As a consequence, several devices and methods have been used to investigate in vitro cyclic fatigue fracture resistance of NiTi rotary endodontic instruments. In nearly all studies reported in the endodontic literature, the rotating instrument was either confined in a glass or metal tube, in a grooved block-and-rod assembly, or in a sloped metal block. RESULTS There has been no mention of the "fit" of the instrument in the tube or groove. As the instrument is likely to be fitting loosely, the description of the radius of curvature in those studies is likely to be overstated (ie, the file was actually bent less severely than reported, adding a variability in the amount of flexural stress). CONCLUSIONS This review analyzed several devices that have been used in endodontic literature for cyclic fatigue testing and found that differences in the methodology affected the fatigue behavior of rotary instruments and, consequently, the outcome of these studies. An international standard for cyclic fatigue testing of NiTi rotary instruments is required to ensure uniformity of methodology and comparable results.

[1]  J. Mitchell,et al.  Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency. , 2008, Journal of endodontics.

[2]  G Gambarini,et al.  Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use. , 2004, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[3]  B. Martín,et al.  Factors influencing the fracture of nickel-titanium rotary instruments. , 2003, International endodontic journal.

[4]  Toshiyuki Takase,et al.  The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue. , 2007, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[5]  Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. , 2001, Journal of endodontics.

[6]  Geoff Bateman,et al.  Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. , 1999 .

[7]  S. W. Schneider,et al.  A comparison of canal preparations in straight and curved root canals. , 1971, Oral surgery, oral medicine, and oral pathology.

[8]  F. Tay,et al.  Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments. , 2007, Journal of endodontics.

[9]  John W H Price,et al.  Fracture resistance of electropolished rotary nickel-titanium endodontic instruments. , 2007, Journal of endodontics.

[10]  O. Peters,et al.  Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments. , 2005, Journal of endodontics.

[11]  A. Pelton,et al.  The Bending Behavior of NiTi , 1995 .

[12]  Jarom J Ray,et al.  Cyclic fatigue of EndoSequence and K3 rotary files in a dynamic model. , 2007, Journal of endodontics.

[13]  A C D Viana,et al.  Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments. , 2006, International endodontic journal.

[14]  Teresa Roberta Tripi,et al.  Cyclic fatigue of different nickel-titanium endodontic rotary instruments. , 2006, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[15]  Low-cycle fatigue of NiTi rotary instruments of various cross-sectional shapes. , 2007, International endodontic journal.

[16]  P Machtou,et al.  Cyclic fatigue of ProFile rotary instruments after clinical use. , 2000, International endodontic journal.

[17]  Hélio Pereira Lopes,et al.  Cyclic fatigue of ProTaper instruments. , 2007, Journal of endodontics.

[18]  M G A Bahia,et al.  Influence of multiple clinical use on fatigue resistance of ProTaper rotary nickel-titanium instruments. , 2007, International endodontic journal.

[19]  An in vitro comparison of torsional stress and cyclic fatigue resistance of ProFile GT and ProFile GT Series X rotary nickel-titanium files. , 2009, Journal of endodontics.

[20]  Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments. , 1998, Journal of endodontics.

[21]  Frederick R Liewehr,et al.  The effect of operational speed on the fracture of nickel-titanium rotary instruments. , 2007, Journal of endodontics.

[22]  Bor-Shiunn Lee,et al.  Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. , 2002, Journal of endodontics.

[23]  G Gambarini,et al.  Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. , 2001, International endodontic journal.

[24]  G. Yared,et al.  Cyclic fatigue of Profile rotary instruments after simulated clinical use. , 1999, International endodontic journal.

[25]  G S P Cheung,et al.  Fatigue testing of a NiTi rotary instrument. Part 1: Strain-life relationship. , 2007, International endodontic journal.

[26]  A. Saxena,et al.  Nickel-titanium instruments : applications in endodontics , 1995 .

[27]  Ya Shen,et al.  Effect of environment on low-cycle fatigue of a nickel-titanium instrument. , 2007, Journal of endodontics.

[28]  Ove A Peters,et al.  Current challenges and concepts in the preparation of root canal systems: a review. , 2004, Journal of endodontics.

[29]  B Peng,et al.  Defects in ProTaper S1 instruments after clinical use: longitudinal examination. , 2005, International endodontic journal.

[30]  V. Malagnino,et al.  A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments. , 2006, International endodontic journal.

[31]  Peter Parashos,et al.  Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. , 2004, Journal of endodontics.

[32]  Ya Shen,et al.  Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite? , 2007, Journal of endodontics.

[33]  The effect of sodium hypochlorite on the surface characteristics and fatigue resistance of ProFile nickel-titanium instruments. , 2006, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[34]  Influence of a brushing working motion on the fatigue life of NiTi rotary instruments. , 2007, International endodontic journal.

[35]  D. Dederich,et al.  The effects of cyclical axial motion on rotary endodontic instrument fatigue. , 1986, Oral surgery, oral medicine, and oral pathology.

[36]  O. Peters,et al.  Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments. , 2007, Journal of endodontics.

[37]  G. Plotino,et al.  Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests. , 2009, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[38]  Gianluca Gambarini,et al.  Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. , 2008, Journal of endodontics.

[39]  B. Sattapan,et al.  Defects in rotary nickel-titanium files after clinical use. , 2000, Journal of endodontics.

[40]  J. P. Pruett,et al.  Cyclic fatigue testing of nickel-titanium endodontic instruments. , 1997, Journal of endodontics.

[41]  Application of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments. , 2006, Dental materials journal.

[42]  Equipment,et al.  Revised ANSI/ADA specifications No. 28 for root canal files and reamers, type K, and No. 58 for root canal files, type H (Hedstrom). Council on Dental Materials, Instruments, and Equipment. , 1989, Journal of the American Dental Association.

[43]  E. Berutti,et al.  Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. , 2006, International endodontic journal.

[44]  V. Buono,et al.  Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals. , 2005, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[45]  Sergio Kuttler,et al.  Comparison between a novel nickel-titanium alloy and 508 nitinol on the cyclic fatigue life of ProFile 25/.04 rotary instruments. , 2008, Journal of endodontics.

[46]  G S P Cheung,et al.  Fatigue testing of a NiTi rotary instrument. Part 2: Fractographic analysis. , 2007, International endodontic journal.

[47]  Maria Guiomar de Azevedo Bahia,et al.  Fatigue Resistance of Engine-Driven Rotary Nickel- Titanium Endodontic Instruments , 2002 .

[48]  Cyclic fatigue of ProTaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature. , 2007, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[49]  Scott A Schwartz,et al.  Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. , 2006, Journal of endodontics.

[50]  G. Cheung,et al.  Defects in ProTaper S1 instruments after clinical use: fractographic examination. , 2005, International endodontic journal.

[51]  Ikuya Watanabe,et al.  Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. , 2009, Journal of endodontics.

[52]  José Antônio da Cunha Ponciano Gomes,et al.  Influence of previous angular deformation on flexural fatigue resistance of K3 nickel-titanium rotary instruments. , 2007 .

[53]  G Plotino,et al.  Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems. , 2006, International endodontic journal.

[54]  John M Powers,et al.  SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical Use. , 2005, Journal of endodontics.