Energy calibration of energy-resolved photon-counting pixel detectors using laboratory polychromatic x-ray beams

Abstract Recently, photon-counting detectors capable of resolving incident x-ray photon energies have been considered for use in spectral x-ray imaging applications. For reliable use of energy-resolved photon-counting detectors (ERPCDs), energy calibration is an essential procedure prior to their use because variations in responses from each pixel of the ERPCD for incident photons, even at the same energy, are inevitable. Energy calibration can be performed using a variety of methods. In all of these methods, the photon spectra with well-defined peak energies are recorded. Every pixel should be calibrated on its own. In this study, we suggest the use of a conventional polychromatic x-ray source (that is typically used in laboratories) for energy calibration. The energy calibration procedure mainly includes the determination of the peak energies in the spectra, flood-field irradiation, determination of peak channels, and determination of calibration curves (i.e., the slopes and intercepts of linear polynomials). We applied a calibration algorithm to a CdTe ERPCD comprised of 128×128 pixels with a pitch of 0.35 mm using highly attenuated polychromatic x-ray beams to reduce the pulse pile-up effect, and to obtain a narrow-shaped spectrum due to beam hardening. The averaged relative error in calibration curves obtained from 16,384 pixels was about 0.56% for 59.6 keV photons from an Americium radioisotope. This pixel-by-pixel energy calibration enhanced the signal- and contrast-to-noise ratios in images, respectively, by a factor of ~5 and 3 due to improvement in image homogeneity, compared to those obtained without energy calibration. One secondary finding of this study was that the x-ray photon spectra obtained using a common algorithm for computing x-ray spectra reasonably described the peaks in the measured spectra, which implies easier peak detection without the direct measurement of spectra using a separate spectrometer. The proposed method will be a useful alternative to conventional approaches using radioisotopes, a synchrotron, or specialized x-ray sources (e.g., characteristic or fluorescent x-rays) by reducing concerns over the beam flux, the irradiation field of view, accessibility, and cost.

[1]  Katsuyuki Taguchi,et al.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors. , 2010 .

[2]  Seungman Yun,et al.  Spectral analysis of fundamental signal and noise performances in photoconductors for mammography. , 2012, Medical physics.

[3]  M. Fiederle,et al.  Optimization of Medipix-2 Threshold Masks for Spectroscopic X-Ray Imaging , 2009, IEEE Transactions on Nuclear Science.

[4]  Goran Ristic,et al.  X-ray imaging performance of structured cesium iodide scintillators. , 2004, Medical physics.

[5]  Giovanni Mettivier,et al.  Evaluation of a photon-counting hybrid pixel detector array with a synchrotron X-ray source , 2002 .

[6]  F Verhaegen,et al.  SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes , 2009, Physics in medicine and biology.

[7]  Ho Kyung Kim,et al.  Finite element analysis of the effects of pixel geometry on the electrical properties in semiconductor pixel detectors , 2013 .

[8]  Uwe Oelfke,et al.  On the energy response function of a CdTe Medipix2 Hexa detector , 2011 .

[9]  B. Phlips,et al.  Nuclear Instruments and Methods in Physics Research A , 2015 .

[10]  K. Spartiotis,et al.  Preliminary evaluation of a novel energy-resolved photon-counting gamma ray detector , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[11]  G. Knoll Radiation detection and measurement , 1979 .

[12]  Uwe Oelfke,et al.  Imaging properties of small-pixel spectroscopic x-ray detectors based on cadmium telluride sensors , 2012, Physics in medicine and biology.

[13]  Ho Kyung Kim,et al.  Computational Toolset for X-Ray Spectral Analysis , 2006 .

[14]  B. Schmitt,et al.  The MYTHEN detector for X-ray powder diffraction experiments at the Swiss Light Source , 2010, Journal of synchrotron radiation.

[15]  A. Mozzanica,et al.  Characterization and Calibration of PILATUS Detectors , 2009, IEEE Transactions on Nuclear Science.

[16]  Thilo Michel,et al.  Reconstruction of X-ray spectra with the energy sensitive photon counting detector Medipix2 , 2009 .

[17]  John M. Boone,et al.  X-Ray Production, Interaction, and Detection in Diagnostic Imaging , 2000 .

[18]  Michael Campbell,et al.  Charge Summing in Spectroscopic X-Ray Detectors With High-Z Sensors , 2013, IEEE Transactions on Nuclear Science.

[19]  R. Plackett,et al.  Characterization of the Medipix3 pixel readout chip , 2011 .

[20]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[21]  J H Siewerdsen,et al.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization. , 2004, Medical physics.

[23]  M Esposito,et al.  14C autoradiography with an energy-sensitive silicon pixel detector , 2011, Physics in medicine and biology.

[24]  S. Evans Catalogue of Diagnostic X-Ray Spectra and Other Data , 1998 .

[25]  D. R. Hill X-Ray Production , 1975 .

[26]  Hyoung-Koo Lee,et al.  Defective pixel map creation based on wavelet analysis in digital radiography detectors , 2011 .

[27]  이화영 X , 1960, Chinese Plants Names Index 2000-2009.

[28]  Polad M Shikhaliev,et al.  Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector , 2009, Physics in medicine and biology.

[29]  Ho Kyung Kim Analytical model for incomplete signal generation in semiconductor detectors , 2006 .

[30]  B. Mikulec,et al.  Development of segmented semiconductor arrays for quantum imaging , 2003 .

[31]  M. Campbell,et al.  Characterisation of a single photon counting pixel system for imaging of low-contrast objects , 2001 .