Optimal control of novel fuel cell-based DVR using ANFISC-MOSSA to increase FRT capability of DFIG-wind turbine

Although Doubly fed induction generator (DFIG)-based wind turbine has several significant advantages, any voltage fluctuation can severely disturb its normal and safe operation, i.e., it is characteristically very sensitive. Hence, fault ride-through is determined as a prominent benchmark for DFIG which must be enhanced by a voltage compensator. Dynamic voltage restorer (DVR), a voltage fluctuation mitigator, is connected in-series with distribution and sub-transmission lines so that DFIG can appropriately operate during any type of disturbance. In this paper, a new two switches boost converter (TSBC) coupled with quinary multilevel inverter (QMLI) is proposed which is fed by fuel cell to produce staircase sinusoidal voltage for DVR. The proposed step-up DC/DC presents two important advantages: low current ripple and low switch stress, while QMLI can create high-step staircase sinusoidal voltage without considering a number of switches. TSBC-QMLI-based DVR has been controlled by neuro fuzzy inference system controller (ANFISC). As the control problem is multi-objective and complex, Multi-Objective Salp Swarm Algorithm (MOSSA) has been applied to optimally tune the ANFISC’s parameters, and then compared with Non-dominated Sorting Genetic Algorithm II (NSGA-II). To verify and validate the compensation capability of proposed DVR, it has been thoroughly evaluated under different voltage disturbances. Eventually, the simulation results have validated the compensation capability of the suggested TSBC-QMLI-based DVR which is accurately controlled by MOSSA-based ANFISC to mitigate the balanced and unbalanced voltage sag and swell along with the flicker and harmonic voltage.

[1]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[2]  Van-Thuyen Ngo,et al.  Designed damping controller for SSSC to improve stability of a hybrid offshore wind farms considering time delay , 2015 .

[3]  Shuo-Fang Liu,et al.  A scale development of industrial designer ability index through quality function deployment and grey relational analysis methods , 2016 .

[4]  Vinod Khadkikar,et al.  Integrated Photovoltaic and Dynamic Voltage Restorer System Configuration , 2015, IEEE Transactions on Sustainable Energy.

[5]  Mouli Ramasamy,et al.  Experimental verification of PV based Dynamic Voltage Restorer (PV-DVR) with significant energy conservation , 2013 .

[6]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[7]  D.G. Holmes,et al.  A comparison of multicarrier PWM strategies for cascaded and neutral point clamped multilevel inverters , 2000, 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018).

[8]  Walmir Freitas,et al.  Three-phase doubly fed induction generators: an overview , 2010 .

[9]  Leopoldo García Franquelo,et al.  > Replace This Line with Your Paper Identification Number (double-click Here to Edit) < , 2022 .

[10]  Mohamad Reza Banaei,et al.  Analysis of a Generalized Symmetrical Multilevel inverter , 2011, J. Circuits Syst. Comput..

[11]  C. Liu,et al.  RETRACTED: Design nonlinear robust damping controller for static synchronous series compensator based on objective holographic feedback–H∞ , 2016 .

[12]  Hossam Faris,et al.  Salp Swarm Algorithm: A bio-inspired optimizer for engineering design problems , 2017, Adv. Eng. Softw..

[13]  L. Madin Aspects of jet propulsion in salps , 1990 .

[14]  Gonzalo Abad,et al.  Single-Phase DC Crowbar Topologies for Low Voltage Ride Through Fulfillment of High-Power Doubly Fed Induction Generator-Based Wind Turbines , 2013, IEEE Transactions on Energy Conversion.

[15]  Ebrahim Babaei,et al.  Reduction of dc voltage sources and switches in asymmetrical multilevel converters using a novel topology , 2007 .

[16]  Sidhartha Panda,et al.  ANFIS approach for SSSC controller design for the improvement of transient stability performance , 2011, Math. Comput. Model..

[17]  M. Muthuselvi,et al.  Design and Analysis of PEM Fuel Cell with Multilevel Inverter Using Multicarrier PWM Techniques , 2016 .

[18]  Ali Mosallanejad,et al.  RETRACTED ARTICLE: Dynamic stability enhancement of interconnected multi-source power systems using hierarchical ANFIS controller-TCSC based on multi-objective PSO , 2017, Frontiers of Information Technology & Electronic Engineering.

[19]  Ali Mosallanejad,et al.  Neoteric HANFISC–SSSC based on MOPSO technique aimed at oscillation suppression of interconnected multi-source power systems , 2016 .

[20]  Amin Hajizadeh,et al.  Control of hybrid fuel cell/energy storage distributed generation system against voltage sag , 2010 .

[21]  A. Betz Introduction to the Theory of Flow Machines , 1966 .

[22]  Mouli Ramasamy,et al.  Optimal Utilization of PV Solar System as DVR (PV-DVR) for a Residence or Small Industry , 2013 .

[23]  P. Nival,et al.  A model of the population dynamics of salps in coastal waters of the Ligurian Sea , 1986 .

[24]  Esam H. Ismail,et al.  A high voltage ratio and low stress DC–DC converter with reduced input current ripple for fuel cell source , 2015 .

[25]  Fernando L. M. Antunes,et al.  Multilevel Inverter Topologies for Stand-Alone PV Systems , 2013, IEEE Transactions on Industrial Electronics.

[26]  Dong-Choon Lee,et al.  A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[27]  K.H. Ahmed,et al.  New flying capacitor multilevel converter , 2011, 2011 IEEE International Symposium on Industrial Electronics.

[28]  G Pannell,et al.  Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind Turbine , 2010, IEEE Transactions on Energy Conversion.

[29]  Miao Liu,et al.  A novel flying-capacitor dual buck three-level inverter , 2013, 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[30]  C Wessels,et al.  Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid Faults , 2011, IEEE Transactions on Power Electronics.

[31]  Mouli Ramasamy,et al.  Photovoltaic based dynamic voltage restorer with power saver capability using PI controller , 2012 .

[32]  Huan Yang,et al.  Topologies and control strategies of multi-functional grid-connected inverters for power quality enhancement: A comprehensive review , 2013 .

[33]  Mohamad Reza Banaei,et al.  Verification of New Family for Cascade Multilevel Inverters with Reduction of Components , 2011 .

[34]  Vassilios G. Agelidis,et al.  Performance evaluation of half-bridge cascaded multilevel converters operated with multicarrier sinusoidal PWM techniques , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[35]  E. Daryabeigi,et al.  Application of brain emotional learning-based intelligent controller to power flow control with thyristor-controlled series capacitance , 2015 .

[36]  Henrik Lund,et al.  Integrated energy systems and local energy markets , 2006 .

[37]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[38]  Mansour Mohseni,et al.  Review of international grid codes for wind power integration: Diversity, technology and a case for global standard , 2012 .

[39]  L.G. Franquelo,et al.  The age of multilevel converters arrives , 2008, IEEE Industrial Electronics Magazine.

[40]  F. Blaabjerg,et al.  Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults , 2010, IEEE Transactions on Power Electronics.

[41]  S. Norrga,et al.  Evaluation of different carrier-based PWM methods for modular multilevel converters for HVDC application , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.