Pull-out behaviour of steel grid soil reinforcement embedded in silty sand

This paper investigates the pull-out behaviour (particularly the bearing resistance) of a steel grid reinforcement embedded in silty sand using laboratory tests and numerical analyses. It is demonstrated that the various common analytical equations for calculating the bearing component of pull-out resistance give a wide range of calculated values, up to about 200% disparity. The disparity will increase further if the issue of whether to use the peak or critical state friction angle is brought in. Furthermore, these equations suggest that the bearing resistance factor, Nq, is only a function of soil friction angle which is not consistent with some design guidelines. In this investigation, a series of large scale laboratory pull-out tests under different test pressures were conducted. The test results unambiguously confirmed that the Nq factor is a function of test pressure. A modified equation for calculating Nq is also proposed. To have more in-depth understanding of the pull-out behaviour, the tests were modelled numerically. The input parameters for the numerical analysis were obtained from laboratory triaxial tests. The analysis results were compared with the experimental results. Good agreement between experimental and numerical results was achieved if the strain-softening behaviour from peak strength to critical state condition was captured by the soil model used.

[1]  M. R. Dyer Observation of the stress distribution in crushed glass with applications to soil reinforcement , 1985 .

[2]  Mark R. Nielsen Pullout Resistance of Welded Wire Mats Embedded in Soil , 1984 .

[3]  J. N. Mandal,et al.  Pullout behaviour of cellular reinforcements , 2009 .

[4]  T. O’Rourke,et al.  Lateral Force-Displacement Response of Buried Pipe , 1985 .

[5]  J. M. Duncan,et al.  Nonlinear Analysis of Stress and Strain in Soils , 1970 .

[6]  S-Cr Lo Pull-Out Resistance of Polyester Straps at Low Overburden Stress , 1998 .

[8]  Dennes T. Bergado,et al.  PULLOUT TESTS USING STEEL GRID REINFORCEMENTS WITH LOW-QUALITY BACKFILL , 1992 .

[9]  Jinchun Chai,et al.  INTERACTION BEHAVIOUR OF STEEL GRID REINFORCEMENTS IN A CLAYEY SAND , 1993 .

[10]  S-Cr Lo,et al.  ON LARGE-SCALE LABORATORY PULLOUT TESTING , 1998 .

[11]  Jun-Hwan Lee,et al.  Pullout capacity of a reinforced soil in drained and undrained conditions , 2008 .

[12]  D. T. Bergado,et al.  Interaction of lateritic soil and steel grid reinforcement , 1993 .

[13]  S W Perkins,et al.  Finite element modeling of a geosynthetic pullout test , 2003 .

[14]  Joe O. Akinmusuru Horizontally Loaded Vertical Plate Anchors in Sand , 1978 .

[15]  R W Sarsby,et al.  INTERACTION BETWEEN SOIL AND GEOGRIDS. POLYMER GRID REINFORCEMENT: PROCEEDINGS OF A CONFERENCE SPONSORED BY THE SCIENCE AND ENGINEERING RESEARCH COUNCIL AND NETLON LTD AND HELD IN LONDON 22-23 MARCH 1984 , 1985 .

[16]  C. Leung,et al.  Centrifugal Model Tests on Vertical Anchor Plates , 1983 .

[17]  M. C. Wang,et al.  Yielding Load of Anchor in Sand , 1982 .

[18]  Jinchun Chai,et al.  Interaction between cohesive-frictional soil and various grid reinforcements , 1993 .

[19]  J. G. Potyondy Skin Friction between Various Soils and Construction Materials , 1961 .

[20]  Gholamreza Mesri,et al.  The coefficient of earth pressure at rest , 1993 .

[21]  K. J. Nyman,et al.  Soil restraint against horizontal motion of pipes , 1977 .

[22]  James K. Mitchell,et al.  Reinforced soil structures. Volume II, Summary of research and systems information , 1989 .

[23]  G. W. E. Milligan,et al.  SCALE AND OTHER FACTORS AFFECTING THE RESULTS OF PULL-OUT TESTS OF GRIDS BURIED IN SAND , 1989 .