The accuracy of extracted target motion trajectories in four-dimensional cone-beam computed tomography for lung cancer patients.

PURPOSE To quantify the accuracy of extracted target motion trajectories in dual-source four-dimensional cone-beam computed tomography (4D-CBCT) by comparison with the actual three-dimensional (3D) target motion acquired simultaneously during 4D-CBCT scan. MATERIALS AND METHODS 4D-CBCT scans were performed for 19 different sinusoidal-like patterns and 13 lung cancer patients with implanted markers. Internal (In) or external (Ex) surrogates with amplitude (Amp)- or phase (Ph)-based sorting were used for the reconstructions. The targets were a pseudo-tumor and implanted marker for the phantom and clinical studies, respectively. The accuracy was evaluated by determining the maximum error (MaxEi) between the 3D target position extracted from 4D-CBCT and the actual 3D target position detected by fluoroscopy in each ith phase (0⩽i⩽7). RESULTS Median peak-to-peak target displacements in the superior-inferior (SI) direction were 20.6 and 20.6mm in the phantom and clinical studies, respectively. In the phantom and clinical studies, the maximum of median MaxEis in the SI direction was 4.6 and 9.2mm in the In_Ph reconstruction. In the clinical study, the maximum of median MaxEis was observed during the end-inhalation phase among all reconstruction approaches. CONCLUSIONS This study showed the magnitude of underestimation toward the inferior direction of target motion in clinical 4D-CBCT.

[1]  Lei Xing,et al.  A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery. , 2011, Medical physics.

[2]  Paul J Keall,et al.  A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy. , 2008, International journal of radiation oncology, biology, physics.

[3]  Steve B. Jiang,et al.  4D CT sorting based on patient internal anatomy , 2009, Physics in medicine and biology.

[4]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[5]  Tinsu Pan,et al.  A pilot evaluation of a 4-dimensional cone-beam computed tomographic scheme based on simultaneous motion estimation and image reconstruction. , 2015, International journal of radiation oncology, biology, physics.

[6]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[7]  D. Low,et al.  A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT. , 2006, Medical physics.

[8]  Timothy D. Solberg,et al.  Phase versus amplitude sorting of 4D‐CT data , 2006, Journal of applied clinical medical physics.

[9]  Fang-Fang Yin,et al.  Potential underestimation of the internal target volume (ITV) from free-breathing CBCT. , 2011, Medical physics.

[10]  Mitsuhiro Nakamura,et al.  Multivariate analysis for the estimation of target localization errors in fiducial marker-based radiotherapy. , 2016, Medical physics.

[11]  Zdenka Kuncic,et al.  Markerless tumor tracking using short kilovoltage imaging arcs for lung image-guided radiotherapy , 2015, Physics in medicine and biology.

[12]  Shifeng Chen,et al.  Margins Determined Using 4DCT Often Underestimate Tumor Motion in Thoracic Tumors , 2013 .