Field distortion compensation for electromagnetic tracking of ultrasound probes with application in high-dose-rate prostate brachytherapy

Purpose: Electromagnetic (EM) tracking of ultrasound (US) probes has been introduced to expand US imaging capabilities and benefit challenging procedures. However, various instruments—including the US probe itself—may introduce dynamic distortions to the EM field, and compromise the EM measurements. Basic filtering methods, such as those provided by manufacturers, are usually inefficient as they do not allow for field distortion compensation. We propose to use a simultaneous localization and mapping (SLAM) algorithm to track the transrectal US (TRUS) probe while dynamically detect, map, and correct the EM field distortions. Methods: Combining the motion model of the tracked probe, the observations made by a few redundant EM sensors, and the field distortions map, the SLAM algorithm relied on an extended Kalman filter (EKF) to estimate the tracking measurements. The SLAM technique was experimentally validated in a brachytherapy suite. Tracking of a TRUS probe was performed by means of an Ascension trakSTAR tracking system and four EM sensors. In addition, an optical tracking system was employed to provide a ground truth to our data. The performance of the SLAM technique was analysed by varying pertinent parameters, such as the number of redundant measurements and the motion trajectory. Probe trajectories included longitudinal translation, rotation, and freehand motions (consisting of simultaneous longitudinal translation and rotation motions) in order to comprehensively simulate imaging scenarios. Finally, the accuracy of the SLAM estimations was compared with that of the standard filtering methods provided by the manufacturer, as well as that of a simpler sensor fusion technique. Results: SLAM efficiently reduced position tracking errors up to 46.4% during freehand motions of the TRUS probe. Moreover, higher SLAM estimation accuracies were observed as the number of redundant measurements increased. While both TRUS probe motions did not yield a clinically significant trend on position tracking accuracy, orientation measurements were considerably improved during translation of the TRUS probe. Conclusions: The SLAM technique was effective in increasing the tracking accuracy of the TRUS probe. Higher number of redundant sensors and favorable sensor configurations improved the SLAM estimations of EM measurements. In turn, SLAM can further encourage the introduction of EM tracking assistance in clinical procedures such as prostate brachytherapy.

[1]  Emmanuel Racine,et al.  Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system. , 2014, Medical physics.

[2]  Martin Ebert,et al.  A small tolerance for catheter displacement in high-dose rate prostate brachytherapy is necessary and feasible. , 2010, International journal of radiation oncology, biology, physics.

[3]  Hugh F. Durrant-Whyte,et al.  Simultaneous localization and mapping: part I , 2006, IEEE Robotics & Automation Magazine.

[4]  Gabor Fichtinger,et al.  Simultaneous localization and calibration for electromagnetic tracking systems , 2016, The international journal of medical robotics + computer assisted surgery : MRCAS.

[5]  May Whitaker,et al.  Prostate HDR brachytherapy catheter displacement between planning and treatment delivery. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  Ehsan Dehghan,et al.  Electromagnetic Catheter Digitization in Prostate High-Dose-Rate Brachytherapy Treatment Planning , 2014 .

[7]  J. Waterton,et al.  Three-dimensional freehand ultrasound: image reconstruction and volume analysis. , 1997, Ultrasound in medicine & biology.

[8]  M. Donat,et al.  Stability of miniature electromagnetic tracking systems. , 2005, Physics in medicine and biology.

[9]  M Birth,et al.  [Ultrasound-guided interventions using magnetic field navigation. First experiences with Ultra-Guide 2000 under operative conditions]. , 2003, Ultraschall in der Medizin.

[10]  Gabor Fichtinger,et al.  Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy , 2017, International Journal of Computer Assisted Radiology and Surgery.

[11]  Ehsan Dehghan,et al.  Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate. , 2014, Brachytherapy.

[12]  Wolfgang Birkfellner,et al.  Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generator , 2012, International Journal of Computer Assisted Radiology and Surgery.

[13]  T Langø,et al.  Navigated ultrasound in laparoscopic surgery , 2009, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[14]  Gabor Fichtinger,et al.  Simultaneous Electromagnetic Tracking and Calibration for Dynamic Field Distortion Compensation , 2016, IEEE Transactions on Biomedical Engineering.

[15]  Jun Zhou,et al.  Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: a preliminary performance study. , 2013, Medical physics.

[16]  V Ferrari,et al.  Simultaneous tracking of catheters and guidewires: comparison to standard fluoroscopic guidance for arterial cannulation. , 2014, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[17]  H. Meinzer,et al.  Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems. , 2006, Ultrasound in medicine & biology.

[18]  Peter Kazanzides,et al.  Multisensor Data Fusion in an Integrated Tracking System for Endoscopic Surgery , 2012, IEEE Transactions on Information Technology in Biomedicine.

[19]  D C Barratt,et al.  Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging. , 2001, Ultrasound in medicine & biology.

[20]  Nawaid Usmani,et al.  Comparison of prostate volume, shape, and contouring variability determined from preimplant magnetic resonance and transrectal ultrasound images. , 2012, Brachytherapy.

[21]  Nassir Navab,et al.  Magneto-Optical Tracking of Flexible Laparoscopic Ultrasound: Model-Based Online Detection and Correction of Magnetic Tracking Errors , 2009, IEEE Transactions on Medical Imaging.

[22]  Gerd Hirzinger,et al.  Optimal Hand-Eye Calibration , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[23]  Robert A. Cormack,et al.  EM-navigated catheter placement for gynecologic brachytherapy: an accuracy study , 2014, Medical Imaging.

[24]  Peter H. Veltink,et al.  Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing , 2007, IEEE Transactions on Biomedical Engineering.

[25]  T. Peters,et al.  Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery. , 2000, Medical physics.

[26]  Gabor Fichtinger,et al.  Nonholonomic catheter path reconstruction using electromagnetic tracking , 2015, Medical Imaging.

[27]  Wolfgang Birkfellner,et al.  Evaluation of a miniature electromagnetic position tracker. , 2002, Medical physics.

[28]  Robert A Cormack,et al.  A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization. , 2014, Medical physics.

[29]  Volodymyr V. Kindratenko,et al.  A survey of electromagnetic position tracker calibration techniques , 2005, Virtual Reality.