A study of estimation techniques for frequency-relaying applications

This paper presents an evaluation and performance comparison of two estimating algorithms used for frequency-relaying applications. The first algorithm is based on least squares (LS) error estimation, while the second is based on the least absolute value (LAV) approximations. Two models for frequency estimation, namely the constant-frequency model (CFM) and the variable-frequency model (VFM), are used. CFM is used to measure the steady-state frequency deviation, while VFM is used to measure the transient frequency and its rate of change. For the constant-frequency model, which is suitable for use in microprocessor-based relays, the algorithms are tested using two data sets. The first involves a pure sine waveform, and the second is a wave generated from the electromagnetic transients program (EMTP) simulating a study system. The EMTP is used to generate the corresponding voltage samples at a relay location. Fault conditions applied on the study system to generate distorted waves with and without frequency deviations are considered. For the variable-frequency model, the algorithms are tested using a data set generated from a pure sine waveform. The effects of sampling rate, sample window size and bad data on the performance of each algorithm are studied. A comparison of the results is offered to evaluate the two techniques.

[1]  M. S. Sachdev,et al.  Off-Nominal Frequency Measurements in Electric Power Systems , 1989, IEEE Power Engineering Review.

[2]  P. Bonanomi Phase Angle Measurements with Synchronized Clocks-Principle and Applications , 1981, IEEE Transactions on Power Apparatus and Systems.

[3]  Mladen Kezunovic,et al.  New digital signal processing algorithms for frequency deviation measurement , 1991 .

[4]  Adly Girgis,et al.  A New FFT-Based Digital Frequency Relay for Load Shedding , 1982, IEEE Transactions on Power Apparatus and Systems.

[5]  M. Sachdev,et al.  A Least Error Squares Technique For Determining Power System Frequency , 1985, IEEE Transactions on Power Apparatus and Systems.

[6]  G. S. Christensen,et al.  A new technique for unconstrained and constrained linear LAV parameter estimation , 1989, Canadian Journal of Electrical and Computer Engineering.

[7]  G. Swift,et al.  The Spectra of Fault-Induced Transients , 1979, IEEE Transactions on Power Apparatus and Systems.

[8]  J. Thorp,et al.  A New Measurement Technique for Tracking Voltage Phasors, Local System Frequency, and Rate of Change of Frequency , 1983, IEEE Transactions on Power Apparatus and Systems.

[9]  Gabriel Benmouyal An Adaptive Sampling-Interval Generator for Digital Relaying , 1989, IEEE Power Engineering Review.

[10]  H. A. Bauman,et al.  The Effect of Frequency Reduction on Plant Capacity and on System Operation [includes discussion] , 1954, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[11]  K. Srinivasan,et al.  A New Technique for Rapid Tracking of Frequency Deviations Based on Level Crossings , 1984, IEEE Transactions on Power Apparatus and Systems.

[12]  R. Adapa,et al.  EMTP-a powerful tool for analyzing power system transients , 1990 .

[13]  R. Adapa,et al.  Running EMTP on PCs , 1993 .