Recovery of dielectric strength after DC interruption in vacuum

In order to investigate the influence of the electrode separation, arc time and frequency of the reverse current on the breaking capacity of vacuum breakers in a DC interrupting process, the dielectric recovery strength was measured after the interruption of a breaker. A high speed actuator mixed with a permanent magnetic actuator and a repulsion actuator was designed. And a circuit which can produce a high voltage pulse was set up to measure the dielectric recovery strength after the extinction of arcs. By the method of forced current-zero, experiments were carried out to interrupt a small DC current in a synthetic test circuit. Then the dielectric recovery strength under conditions of different electrode separations, different arc time and different frequencies of the reverse current was measured with the method of monopole discharge. The experimental results indicated that there existed a critical electrode separation in the DC interrupting process. Within this electrode separation, the dielectric recovery strength can be enhanced by increasing the electrode separation and decreasing the arc time. In addition, decreasing the frequency of the reverse current can also improve the dielectric recovery strength.

[1]  G. A. Farrall,et al.  Vacuum arc recovery phenomena , 1964 .

[2]  Allan N. Greenwood,et al.  HYDC Vacuum Circuit Breakers , 1972 .

[3]  Allan N. Greenwood,et al.  Theory and Application of the Commutation Principle for HVDC Circuit Breakers , 1972 .

[4]  G. Farrall Recovery of Dielectric Strength after Current Interruption in Vacuum , 1978, IEEE Transactions on Plasma Science.

[5]  RECOVERY TIMESOF VACUUM INTERRUPTERS WHICH HAVE STATIONARYANODE SPOTS , 1982 .

[7]  E. Huber,et al.  Dielectric recovery of copper chromium vacuum interrupter contacts after short circuit interruption , 1996 .

[8]  Z. Załucki,et al.  Dielectric strength of a vacuum interrupter contact gap after making current operations , 2003 .

[9]  Zou Ji-yan Comparison Analysis of Experiment Performace between High-speed Repulsion Mechanism and Permanent Magnetic Mechanism , 2007 .

[10]  Simulation Analysis of Influence of Electrode Separations on Vacuum Arcs Characteristics Under Different States , 2008 .

[11]  Yue Chang-xi Investigations on High-speed Actuator of Vacuum DC Circuit Breaker , 2010 .

[12]  Z. Q. Shi,et al.  Investigation on DC interruption based on artificial current zero of vacuum switch , 2010, 24th ISDEIV 2010.

[13]  Sun Baojun Dielectric Recovery Experiment Device after Arc Extinction for Vacuum Circuit Breaker , 2011 .

[14]  Liu,et al.  Vacuum Dielectric Recovery Characteristics of a Novel Current Limiting Circuit Breaker Base on Artificial Current Zero , 2012 .

[15]  Jiang Zhuangxian Dielectric Recovery Experimentation and Analysis of DC Vacuum Circuit Breaker Interrupting in Short Contact Gap , 2012 .

[16]  Wang Che Design and Dielectric Recovery Research of Novel Hybrid Current Limiting Fuse , 2013 .