An Interline Dynamic Voltage Restoring and Displacement Factor Controlling Device (IVDFC)

An interline dynamic voltage restorer (IDVR) is invariably employed in distribution systems to mitigate voltage sag/swell problems. An IDVR merely consists of several dynamic voltage restorers (DVRs) sharing a common dc link connecting independent feeders to secure electric power to critical loads. While one of the DVRs compensates for the local voltage sag in its feeder, the other DVRs replenish the common dc-link voltage. For normal voltage levels, the DVRs should be bypassed. Instead of bypassing the DVRs in normal conditions, this paper proposes operating the DVRs, if needed, to improve the displacement factor (DF) of one of the involved feeders. DF improvement can be achieved via active and reactive power exchange (PQ sharing) between different feeders. To successfully apply this concept, several constraints are addressed throughout the paper. Simulation and experimental results elucidate and substantiate the proposed concept.

[1]  A. Y. Chikhani,et al.  Feeder reconfiguration for loss reduction: an application of distribution automation , 1991 .

[2]  San Shing Choi,et al.  Interline dynamic voltage restorer: an economical way to improve interline power quality , 2003 .

[3]  Kavitha Busi,et al.  Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer during Symmetrical and Asymmetrical Grid Faults , 2013 .

[4]  Rosli Omar,et al.  Implementation and control of a dynamic voltage restorer using Space Vector Pulse Width Modulation (SVPWM) for voltage sag mitigation , 2009, 2009 International Conference for Technical Postgraduates (TECHPOS).

[5]  B Bae,et al.  Line-Interactive Single-Phase Dynamic Voltage Restorer With Novel Sag Detection Algorithm , 2010, IEEE Transactions on Power Delivery.

[6]  Jinjun Liu,et al.  A Novel DC Voltage Control Method for STATCOM Based on Hybrid Multilevel H-Bridge Converter , 2013, IEEE Transactions on Power Electronics.

[7]  D. Mahinda Vilathgamuwa,et al.  A Novel Technique to Compensate Voltage Sags in Multiline Distribution System—The Interline Dynamic Voltage Restorer , 2006, IEEE Transactions on Industrial Electronics.

[8]  B. Magadum,et al.  Minimization of Power Loss in Distribution Networks by Different Techniques , 2012 .

[9]  D. Qureshi,et al.  Efficient power factor improvement technique and energy conservation of power system , 1995, Proceedings 1995 International Conference on Energy Management and Power Delivery EMPD '95.

[10]  G. B. Gharehpetian,et al.  Three-Phase HFL-DVR With Independently Controlled Phases , 2012, IEEE Transactions on Power Electronics.

[11]  B. Singh,et al.  Adaptive Theory-Based Improved Linear Sinusoidal Tracer Control Algorithm for DSTATCOM , 2013, IEEE Transactions on Power Electronics.

[12]  S. Afsharnia,et al.  A Fast and Effective Control Scheme for the Dynamic Voltage Restorer , 2011, IEEE Transactions on Power Delivery.

[13]  M. K. Mishra,et al.  A DSTATCOM Topology With Reduced DC-Link Voltage Rating for Load Compensation With Nonstiff Source , 2012, IEEE Transactions on Power Electronics.

[14]  M. Takasaki,et al.  A Transformerless D-STATCOM Based on a Multivoltage Cascade Converter Requiring No DC Sources , 2012, IEEE Transactions on Power Electronics.

[15]  An Luo,et al.  Combined System for Harmonic Suppression and Reactive Power Compensation , 2009, IEEE Transactions on Industrial Electronics.

[16]  A. Keane,et al.  Optimal allocation of embedded generation on distribution networks , 2005, IEEE Transactions on Power Systems.

[17]  D Ramirez,et al.  Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[18]  K. K. Sen,et al.  The interline power flow controller concept: a new approach to power flow management in transmission systems , 1999 .

[19]  Barry W. Williams,et al.  Evaluation of a Multilevel Cascaded-Type Dynamic Voltage Restorer Employing Discontinuous Space Vector Modulation , 2010, IEEE Transactions on Industrial Electronics.

[20]  J. Grainger,et al.  Optimum Size and Location of Shunt Capacitors for Reduction of Losses on Distribution Feeders , 1981, IEEE Transactions on Power Apparatus and Systems.

[21]  Ahmed Elserougi,et al.  Investigation of Inter-Line Dynamic Voltage Restorer with virtual impedance injection , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[22]  R. S. Kemerer,et al.  Directly connected static VAr compensation in distribution system applications , 1998, 1998 Rural Electric Power Conference Presented at 42nd Annual Conference.

[23]  Ahmed M. Massoud,et al.  Investigation of Inter Feeder Power Flow Regulator: Load Sharing Mode , 2010 .

[24]  M. R. Banaei,et al.  A NOVEL MINIMAL ENERGY CONSUMPTION STRATEGY FOR THE INTERLINE DYNAMIC VOLTAGE RESTORER , 2005 .