Analysis and Measures of Ultralow-Frequency Oscillations in a Large-Scale Hydropower Transmission System

The Yunnan power grid has a large-scale hydropower station, whereby the power generated at the station is transmitted via HVdc lines under an asynchronous operation mode. In the system performance test of the Yunnan asynchronous operation, a 0.05-Hz ultralow-frequency oscillation occurred in the grid. This ultralow-frequency oscillation is a frequency stability problem caused by instability of hydraulic turbine governing system, which is quite common in the islanded system and very rare in the normal synchronous system. The relationship between the speed governing system stability of one unit and that of the system with parallel operation units was proposed to explain that the high proportion of units with an unstable governing system will lead to system frequency instability and the reduction in loads in the traditional sense was proven to further worsen the frequency stability of the Yunnan asynchronous system. By using related measures, the ultralow-frequency oscillation of the Yunnan asynchronous system has been curbed effectively. System performance testing verified the effectiveness of the analysis and the measures.

[1]  Ferber R. Schleif,et al.  Damping for the Northwest - Southwest Tieline Oscillations - An Analog Study , 1966 .

[2]  J. P. Bayne,et al.  Hydraulic Unit Dynamic Performance Under Normal and Islanding Conditions -- Analysis and Validation , 1978, IEEE Transactions on Power Apparatus and Systems.

[3]  L. M. Hovey Optimum Adjustment of Hydro Governors on Manitoba Hydro System , 1962, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[4]  Ferber R. Schleif,et al.  Damping of System Oscillations with a Hydrogenerating Unit , 1967 .

[5]  M. E. Cebeci,et al.  THE EFFECTS OF HYDRO POWER PLANTS ’ GOVERNOR SETTINGS ON THE STABILITY OF TURKISH POWER SYSTEM FREQUENCY , 2007 .

[6]  Peter Fairley,et al.  Why Southern China broke up its power grid [News] , 2016 .

[7]  Charles Concordia,et al.  Concepts of Synchronous Machine Stability as Affected by Excitation Control , 1969 .

[8]  F. R. Schleif,et al.  The Coordination of Hydraulic Turbine Governors for Power System Operation , 1966 .

[9]  P. Kundur,et al.  Definition and classification of power system stability IEEE/CIGRE joint task force on stability terms and definitions , 2004, IEEE Transactions on Power Systems.

[10]  M. V. Hariharan,et al.  Analysis and Improvement of the Stability of a Hydro-Turbine Generating Unit With Long Penstock , 1984, IEEE Transactions on Power Apparatus and Systems.

[11]  R. P. Saini,et al.  A review on hydropower plant models and control , 2007 .

[12]  Hongyang Zhou,et al.  The China Southern Power Grid: Solutions to Operation Risks and Planning Challenges , 2016, IEEE Power and Energy Magazine.

[13]  Dionysios Aliprantis,et al.  Analysis of Hydro-Coupled Power Plants and Design of Robust Control to Damp Oscillatory Modes , 2015, IEEE Transactions on Power Systems.

[14]  H. E. Wichert,et al.  Analysis of P.I.D. Governors in Multimachine System , 1978, IEEE Transactions on Power Apparatus and Systems.

[15]  Zhiqian Bo,et al.  Developments of power system protection and control , 2016 .

[16]  Graham Rogers,et al.  Power System Oscillations , 1999 .

[17]  Yu Da THE PRIMARY FREQUENCY REGULATION STABILITY OF PARALLEL TURBO-GENERATORS , 2000 .

[18]  J. D. McCalley,et al.  Analysis of Very Low Frequency Oscillations in Hydro-Dominant Power Systems Using Multi-Unit Modeling , 2012, IEEE Transactions on Power Systems.

[19]  E.F. Hill,et al.  Analysis and Application of the Stability Limits of a Hydro-Generating Unit , 1981, IEEE Transactions on Power Apparatus and Systems.