Breathing-synchronized delivery: a potential four-dimensional tomotherapy treatment technique.

PURPOSE To introduce a four-dimensional (4D) tomotherapy treatment technique with improved motion control and patient tolerance. METHODS AND MATERIALS Computed tomographic images at 10 breathing phases were acquired for treatment planning. The full exhalation phase was chosen as the planning phase, and the CT images at this phase were used as treatment-planning images. Region of interest delineation was the same as in traditional treatment planning, except that no breathing motion margin was used in clinical target volume-planning target volume expansion. The correlation between delivery and breathing phases was set assuming a constant gantry speed and a fixed breathing period. Deformable image registration yielded the deformation fields at each phase relative to the planning phase. With the delivery/breathing phase correlation and voxel displacements at each breathing phase, a 4D tomotherapy plan was obtained by incorporating the motion into inverse treatment plan optimization. A combined laser/spirometer breathing tracking system has been developed to monitor patient breathing. This system is able to produce stable and reproducible breathing signals representing tidal volume. RESULTS We compared the 4D tomotherapy treatment planning method with conventional tomotherapy on a static target. The results showed that 4D tomotherapy can achieve dose distributions on a moving target similar to those obtained with conventional delivery on a stationary target. Regular breathing motion is fully compensated by motion-incorporated breathing-synchronized delivery planning. Four-dimensional tomotherapy also has close to 100% duty cycle and does not prolong treatment time. CONCLUSION Breathing-synchronized delivery is a feasible 4D tomotherapy treatment technique with improved motion control and patient tolerance.

[1]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[2]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[3]  R K Ten Haken,et al.  Estimation of tumor control probability model parameters from 3-D dose distributions of non-small cell lung cancer patients. , 1999, Lung cancer.

[4]  J. Herndon,et al.  Improved survival in stage III non-small-cell lung cancer: seven-year follow-up of cancer and leukemia group B (CALGB) 8433 trial. , 1996, Journal of the National Cancer Institute.

[5]  T Kozuka,et al.  Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study. , 1998, Radiology.

[6]  R. Jeraj,et al.  Treatment plan optimization incorporating respiratory motion. , 2004, Medical physics.

[7]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[8]  T. Mackie,et al.  Fast free-form deformable registration via calculus of variations , 2004, Physics in medicine and biology.

[9]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[10]  J. Fowler,et al.  Reduction in Radiation Dose to Lung and Other Normal Tissues Using Helical Tomotherapy to Treat Lung Cancer, in Comparison to Conventional Field Arrangements , 2003, American journal of clinical oncology.

[11]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[12]  P J Keall,et al.  The application of the sinusoidal model to lung cancer patient respiratory motion. , 2005, Medical physics.

[13]  Paul Keall,et al.  Real-time DMLC IMRT delivery for mobile and deforming targets. , 2005, Medical physics.

[14]  H. Mostafavi,et al.  Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center. , 2000, Medical physics.

[15]  Steve B Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. , 2003, Physics in medicine and biology.

[16]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[17]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[18]  T. Rockwell Mackie,et al.  Helical Tomotherapy: An Innovative Technology and Approach to Radiation Therapy , 2002, Technology in cancer research & treatment.

[19]  M. I. Saunders,et al.  Randomised multicentre trials of CHART vs conventional radiotherapy in head and neck and non-small-cell lung cancer: an interim report. CHART Steering Committee. , 1996, British Journal of Cancer.

[20]  T R Mackie,et al.  A feasible method for clinical delivery verification and dose reconstruction in tomotherapy. , 2001, Medical physics.

[21]  Steve B. Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching , 2006, Physics in medicine and biology.

[22]  Harry Keller,et al.  Application of the spirometer in respiratory gated radiotherapy. , 2003, Medical physics.

[23]  T. Mackie,et al.  Megavoltage CT on a tomotherapy system. , 1999, Physics in medicine and biology.

[24]  E. Yorke,et al.  Respiratory gating for liver tumors: Use in dose escalation , 2003 .