Dynamic behavior of tripolar hip endoprostheses under physiological conditions and their effect on stability.

Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs.

[1]  H. Tsumura,et al.  Does the Self-Centering Mechanism of Bipolar Hip Endoprosthesis Really Work in vivo? , 2005, Journal of orthopaedic surgery.

[2]  T D Brown,et al.  Finite element analysis of a novel design approach to resisting total hip dislocation. , 1999, Clinical biomechanics.

[3]  Qingshan Chen,et al.  Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis. , 2005, Medical engineering & physics.

[4]  E. Y. Chao,et al.  Biomechanics of bipolar hip endoprostheses , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  F. Kummer,et al.  The effect of acetabular cup orientations on limiting hip rotation. , 1999, The Journal of arthroplasty.

[6]  M. Möllers,et al.  [Hemi-arthroplasty of the hip joint: concentric or positive eccentric (self-centering) dual head prosthesis? A retrospective comparison]. , 1992, Der Unfallchirurg.

[7]  Zhongmin Jin,et al.  Friction of total hip replacements with different bearings and loading conditions. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[8]  Jun-Dong Chang,et al.  Bioceramics and alternative bearings in joint arthroplasty , 2007 .

[9]  E Steinhauser,et al.  Methode zur Evaluierung von Einflußfaktoren auf die Luxationsstabilität von künstlichen Hüftgelenken / Method for the Evaluation of Factors Influencing the Dislocation Stability of Total Hip Endoprotheses , 2004, Biomedizinische Technik. Biomedical engineering.

[10]  Mel S. Lee,et al.  The position of the bipolar cup reflects the direction of the hip contact force acting on it. , 2007, The Journal of arthroplasty.

[11]  D. Murray The definition and measurement of acetabular orientation. , 1993, The Journal of bone and joint surgery. British volume.

[12]  Christian Fabry,et al.  Generation of physiological parameter sets for hip joint motions and loads during daily life activities for application in wear simulators of the artificial hip joint. , 2013, Medical engineering & physics.

[13]  R. Philippot,et al.  Prevention of dislocation in total hip revision surgery using a dual mobility design. , 2009, Orthopaedics & traumatology, surgery & research : OTSR.

[14]  K. An,et al.  Unconstrained Tripolar Hip Implants: Effect on Hip Stability , 2007, Clinical orthopaedics and related research.

[15]  O. Guyen,et al.  Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability , 2009, Clinical orthopaedics and related research.

[16]  F. Guterl,et al.  Compact disc , 1988 .

[17]  Daniel Kluess,et al.  Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement. , 2007, Medical engineering & physics.

[18]  Luc Bidaut,et al.  The hip joint range of motion: a cadaveric study. , 2000 .

[19]  J. Lazennec,et al.  Why use an all Ceramic Tripolar THR ? — clinical and experimental data , 2007 .

[20]  H. Amstutz,et al.  Tripolar hip replacement for recurrent prosthetic dislocation. , 1994, Clinical orthopaedics and related research.

[21]  D. Biau,et al.  The Use of a Cemented Dual Mobility Socket to Treat Recurrent Dislocation , 2010, Clinical orthopaedics and related research.

[22]  T. Yoon,et al.  Why does outer joint motion predominate in bipolar hip prosthesis?Experimental and clinical studies , 2004 .

[23]  C. Lautridou,et al.  The dual mobility socket concept: experience with 668 cases , 2011, International Orthopaedics.