Résultats à 10 ans de la prothèse totale de hanche cimentée autoblocante de Müller avec cupule en polyéthylène en diamètre de 28 mm
暂无分享,去创建一个
P. Faure | S. Descamps | S. Boisgard | P. Moreel | J. Levai
[1] Christophe Tilmant,et al. Monitoring of polyethylene wear in nonmetal-backed acetubular cups by digitized anteroposterior pelvic radiography , 2003, IEEE Transactions on Medical Imaging.
[2] D. Sochart,et al. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. , 1999, Clinical orthopaedics and related research.
[3] W. Hozack,et al. Twenty year survivorship of 1,157 charnley cemented total hip arthroplasties , 1997 .
[4] R C Johnston,et al. Charnley Total Hip Arthroplasty with Use of Improved Techniques of Cementing. The Results after a Minimum of Fifteen Years of Follow-up* , 1997, The Journal of bone and joint surgery. American volume.
[5] P. Herberts,et al. Long-term clinical and radiological results of the Lord total hip prosthesis. A prospective study. , 1996, The Journal of bone and joint surgery. British volume.
[6] P. Herberts,et al. Long-term clinical and radiological results of the Lord total hip prosthesis , 1996 .
[7] F. Dorey,et al. The need for confidence intervals in the presentation of orthopaedic data. , 1993, The Journal of bone and joint surgery. American volume.
[8] L Sedel,et al. Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. , 1992, Clinical orthopaedics and related research.
[9] L. Munuera,et al. Early and late loosening of the acetabular cup after low-friction arthroplasty. , 1992, The Journal of bone and joint surgery. American volume.
[10] C. Engh,et al. Evaluation of cementless acetabular component migration. An experimental study. , 1989, The Journal of arthroplasty.
[11] Wroblewski Bm. 15-21-year results of the Charnley low-friction arthroplasty. , 1986 .
[12] W H Harris,et al. Femoral component loosening using contemporary techniques of femoral cement fixation. , 1982, The Journal of bone and joint surgery. American volume.
[13] H. Amstutz,et al. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. , 1979, Clinical orthopaedics and related research.
[14] J. Charnley,et al. Radiological demarcation of cemented sockets in total hip replacement. , 1976, Clinical orthopaedics and related research.
[15] L. Riley,et al. Ectopic ossification following total hip replacement. Incidence and a method of classification. , 1973, The Journal of bone and joint surgery. American volume.
[16] L. Sedel,et al. The 'French paradox.'. , 2003, The Journal of bone and joint surgery. British volume.
[17] J. van Limbeek,et al. Results with the M. E. Müller cemented, straight-stem total hip prosthesis: a 10-year historical cohort study in 180 women. , 2001, The Journal of arthroplasty.
[18] L. Kerboull,et al. Prevention of heterotopic ossification in hip arthroplasty , 1999, International Orthopaedics.
[19] P Herberts,et al. Prognosis of total hip replacement. , 1996, International Journal of Risk and Safety in Medicine.
[20] R. Merled'Aubigné,et al. [Numerical classification of the function of the hip. 1970]. , 1990, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.