Moving slice septa and pseudo three-dimensional reconstruction for multi-ring PET

Describes moving slice septa for reducing scattered and random events in multi-ring positron emission tomographs (PET) and a new simple method of three-dimensional (3D) image reconstruction which is useful when the maximum axial acceptance angle of coincidence is not too large. The moving septa considered are linear and sinusoidal piston motions of parallel septa, axis wobbling of parallel septa and rotation of spiral septa. The proposed reconstruction algorithm is basically a filtered (1D) backprojection (3D) method. The low frequency image is reconstructed using direct (and cross) plane coincidence as in the conventional way, and the high frequency image is reconstructed using all projection data through high-pass filtering. The two images are superimposed in such a way that the final frequency response is normal. The axial cross talk is effectively eliminated by Gaussian high-pass filtering with negligible increase in statistical noise, and it is possible to include most of the oblique coincidence events in the reconstruction in a single pass. Simulation studies with a maximum axial acceptance angle of +or-7.6 degrees (+or-10 ring difference) show satisfactory results.

[1]  A Geissbuhler,et al.  Implementation of three-dimensional image reconstruction for multi-ring positron tomographs. , 1990, Physics in medicine and biology.

[2]  M. Defrise,et al.  Three dimensional reconstruction of PET data from a multi-ring camera , 1989 .

[3]  Z. H. Cho,et al.  True Three-Dimensional Reconstruction (TTR) Application of Algorithm toward Full Utilization of Oblique Rays , 1983, IEEE Transactions on Medical Imaging.

[4]  M Defrise,et al.  Three-dimensional image reconstruction from complete projections , 1989, Physics in medicine and biology.

[5]  Jong Beom Ra,et al.  A true three-dimensional reconstruction algorithm for the spherical positron emission tomograph , 1982 .

[6]  T A Iinuma,et al.  Correction functions for optimizing the reconstructed image in transverse section scan. , 1975, Physics in medicine and biology.

[7]  Christopher J. Thompson,et al.  The effect of collimation on scatter fraction in multi-slice PET , 1988 .

[8]  Paul Kinahan,et al.  The Theory of Three-Dimensional Image Reconstruction for PET , 1987, IEEE Transactions on Medical Imaging.

[9]  Christopher J. Thompson The effect of collimation on single rates in multi-slice PET , 1989 .

[10]  D. P. Saylor,et al.  Design of a volume-imaging positron emission tomograph , 1989 .

[11]  Joel S. Karp,et al.  Design and performance of a new positron tomograph , 1988 .

[12]  C. Bohm,et al.  A study of the possibility of using multi-slice PET systems for 3D imaging , 1989 .

[13]  Eiichi Tanaka,et al.  Properties Of Statistical Noise In Positron Emission Tomography , 1982, Other Conferences.

[14]  M. Defrise,et al.  An algorithm for three-dimensional reconstruction incorporating cross-plane rays. , 1989, IEEE transactions on medical imaging.