New insights into silt density index and modified fouling index measurements

In order to investigate the accuracy and reproducibility of the parameters SDI (silt density index) and MFI (modified fouling index), tests in diverse conditions were performed: with three different types of filter holder, two microfilter pore sizes, with and without permeate spacer and with two foulants (alginate as organic foulant and silica flour as the particulate). Additionally the effect of pressure on fouling indices was analysed. It was concluded, that there is a need to define more boundary conditions in the ASTM standard (exact type of filter holder, exact type of membrane, start conditions) for the SDI to achieve a parameter with reliable and comparable values. But in comparison to MFI, SDI seems to be a more robust parameter for a use in practice pertaining to the influence of a feed pressure level and the effective membrane area. The MFI gives more insights in acting mechanisms and offers advantages for research. It shows a correlation to a concentration of particulate or organic foulants. Like the SDI, it is necessary to define and standardize exact boundary conditions for the MFI tests (classified by the use of MF, UF or NF filter media).

[1]  J. C. Schippers,et al.  Predicting flux decline of reverse osmosis membranes , 1981 .

[2]  Rolf Gimbel,et al.  A comparative study of fouling-index and fouling-potential of waters to be treated by reverse osmosis , 1990 .

[3]  Chanhyuk Park,et al.  Variation and prediction of membrane fouling index under various feed water characteristics , 2006 .

[4]  Gilbert Galjaard,et al.  Monitoring particulate fouling in membrane systems , 1998 .

[5]  Johannes S. Vrouwenvelder,et al.  Tools for fouling diagnosis of NF and RO membranes and assessment of the fouling potential of feed water , 2003 .

[6]  J. C. Schippers,et al.  The modified fouling index, a method of determining the fouling characteristics of water , 1980 .

[7]  Seymour S. Kremen,et al.  Silt density indices (SDI), percent plugging factor (%PF): their relation to actual foulant deposition , 1998 .

[8]  S. Boerlage,et al.  Scaling and Particulate Fouling in Membrane Filtration Systems , 2001 .

[9]  W. Koros,et al.  Terminology for membranes and membrane processes (IUPAC Recommendations 1996) , 1996 .

[10]  Roger Ben Aim,et al.  Improving the measurement of the Modified Fouling Index using nanofiltration membranes (NF-MFI) , 2006 .

[11]  Veronique Bonnelye,et al.  The sensitivity of SDI analysis: from RO feed water to raw water , 2008 .

[12]  Maria D. Kennedy,et al.  Development of the MFI-UF in constant flux filtration , 2004 .

[13]  S. G. Yiantsios,et al.  Colloidal fouling of RO membranes: an overview of key issues and efforts to develop improved prediction techniques , 2005 .