Fractional order PID control for LFC problem of a hydro-thermal power system

This paper presents a fractional order proportional integral derivative order controller, popularly known as FOPID controller for load frequency control problem of a two-area hydro-thermal power system. The objective of this study is to present a non-conventional way of robust control for the load frequency control problem. In this study, a performance index — Integral of absolute error has been used to formulate a cost function which is later minimized using differential evolution algorithm. The algorithm solves the optimization problem and determines the optimal value of parameters of FOPID controller. The FOPID controller has been tested under different operating conditions to verify its superiority over proportional integral (PI) controller. The system response obtained through simulation studies using FOPID controller has been compared with PI controller and the obtained response of system displays the effectiveness of FOPID control over PI control.

[1]  Nasser Sadati,et al.  Two-level optimal load–frequency control for multi-area power systems , 2013 .

[2]  Kazi Rehnuma Zafreen,et al.  Differential evolution algorithm based load frequency control in a two-area conventional and renewable energy based nonlinear power system , 2016, 2016 4th International Conference on the Development in the in Renewable Energy Technology (ICDRET).

[3]  Muwaffaq I. Alomoush,et al.  Load frequency control and automatic generation control using fractional-order controllers , 2010 .

[4]  Ali Mohammad Ranjbar,et al.  Robust analysis and design of power system load frequency control using the Kharitonov's theorem , 2014 .

[5]  Saurabh Chanana,et al.  Application of tilt integral derivative control on two-area power system , 2016 .

[6]  Amit Patra,et al.  Automatic generation control of an interconnected hydrothermal power system considering superconducting magnetic energy storage , 2007 .

[7]  Rajeev Gupta,et al.  Optimization of LFC using Bacteria Foraging Optimization Algorithm , 2013 .

[8]  G. Sheblé,et al.  Power generation operation and control — 2nd edition , 1996 .

[9]  Saurabh Chanana,et al.  Load frequency control of a two-area multi-source power system using a tilt integral derivative controller , 2018 .

[10]  Yogesh V. Hote,et al.  Fractional order PID controller for load frequency control , 2014 .

[11]  Olle Ingemar Elgerd,et al.  Electric energy systems theory , 1982 .

[12]  Lalit Chandra Saikia,et al.  Automatic generation control of a multi area hydrothermal system using reinforced learning neural network controller , 2011 .

[13]  J. Nanda,et al.  Some new findings on automatic generation control of an interconnected hydrothermal system with conventional controllers , 2006, IEEE Transactions on Energy Conversion.

[14]  Aditya,et al.  Design of Load Frequency Controllers Using Genetic Algorithm for Two Area Interconnected Hydro Power System , 2003 .

[15]  Rainer Storn,et al.  Differential Evolution – A Simple and Efficient Heuristic for global Optimization over Continuous Spaces , 1997, J. Glob. Optim..

[16]  E. S. Ali,et al.  Bacteria foraging optimization algorithm based load frequency controller for interconnected power system , 2011 .

[17]  A. M. Abdel Ghany,et al.  Optimal Tuning of PID Controllers for Hydrothermal Load Frequency Control Using Ant Colony Optimization , 2013 .

[18]  I. Podlubny Fractional-order systems and PIλDμ-controllers , 1999, IEEE Trans. Autom. Control..