Design considerations and quantitative assessment for the development of percutaneous mitral valve stent.

Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral regurgitation, by virtue of their key features as well as effective crimping. These models will be fabricated and put to all the aforementioned tests before being taken for animal trials.

[1]  Nader Moazami,et al.  Recurrent mitral regurgitation and risk factors for early and late mortality after mitral valve repair for functional ischemic mitral regurgitation. , 2008, The Annals of thoracic surgery.

[2]  F. Heim,et al.  A novel stent for percutaneous heart valve implantation: first in vitro results. , 2010, Journal of biomechanical engineering.

[3]  Douglas C. Hansen,et al.  Metal Corrosion in the Human Body : The Ultimate Bio-Corrosion Scenario , 2008 .

[4]  Jochen Renner,et al.  Off-pump transapical mitral valve replacement. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  Neil Morgan,et al.  Medical shape memory alloy applications—the market and its products , 2004 .

[6]  J. Renner,et al.  Mitral valved stent implantation. , 2010, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[7]  S. W. Robertson,et al.  Mechanical fatigue and fracture of Nitinol , 2012 .

[8]  N. Stolf,et al.  Long-term follow up of the Biocor porcine bioprosthesis in the mitral position. , 2006, The Journal of heart valve disease.

[9]  Ludwig K von Segesser,et al.  Double-crowned valved stents for off-pump mitral valve replacement. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  M. Leon,et al.  Prospects for Percutaneous Valve Therapies , 2007, Circulation.

[11]  C. Ruiz,et al.  Percutaneous transcatheter mitral valve repair: a classification of the technology. , 2011, JACC. Cardiovascular interventions.

[12]  C. Scheffer,et al.  Application of the finite element method in the fatigue life prediction of a stent for a percutaneous heart valve , 2012 .

[13]  Scott Lim,et al.  Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. , 2009, Journal of the American College of Cardiology.

[14]  J. Cremer,et al.  Transapical mitral valved stent implantation. , 2008, The Annals of thoracic surgery.

[15]  E Peña,et al.  Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent. , 2012, Journal of the mechanical behavior of biomedical materials.

[16]  P. Acar,et al.  Congenital malformations of the mitral valve. , 2011, Archives of cardiovascular diseases.

[17]  T W Duerig,et al.  An Overview of Superelastic Stent Design , 2000, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[18]  Ahmet Erdemir,et al.  Simulation Based Design and Evaluation of a Transcatheter Mitral Heart Valve Frame. , 2012, Journal of medical devices.

[19]  P. Herijgers,et al.  Fifteen-year experience with the mitral Carpentier-Edwards PERIMOUNT pericardial bioprosthesis. , 2001, The Annals of thoracic surgery.

[20]  Fangsen Cui,et al.  Design and finite element-based fatigue prediction of a new self-expandable percutaneous mitral valve stent , 2013, Comput. Aided Des..

[21]  M. Mitchell,et al.  Fatigue to Fracture: An Informative, Fast, and Reliable Approach for Assessing Medical Implant Durability , 2009 .

[22]  C. Duran,et al.  Outcome after mitral valve repair for functional ischemic mitral regurgitation. , 2002, The Journal of heart valve disease.

[23]  C. Kleinstreuer,et al.  Computational mechanics of Nitinol stent grafts. , 2008, Journal of biomechanics.