Performance improvement and analysis of a 1.6 μm continuous-wave modulation laser absorption spectrometer system for CO2 sensing.

In a previous study, we developed a 1.6 μm continuous-wave (cw) modulation laser absorption spectrometer system for CO(2) sensing and demonstrated the measurement of small fluctuations in CO(2) corresponding to a precision of 4 parts per million (ppm) with a measurement interval of 32 s. In this paper, we present the process to achieve this highly specific measurement by introducing important points, which have not been shown in the previous study. Following the results of preliminary experiments, we added a function for speckle averaging on the optical antenna unit. We additionally came up with some ideas to avoid the influences of etalon effects and polarization dependence in optical components. Because of the new functions, we realized a calibration precision of 0.006 dB (rms), which corresponds to a CO(2) concentration precision of less than 1 ppm for a 2 km path. We also analyzed the CO(2) sensing performance after the improvements described above. The measured short time fluctuation of the differential absorption optical depth was reasonably close to that calculated using the carrier-to-noise ratio of the received signal.

[1]  Philippe Ciais,et al.  Retrieval of average CO2 fluxes by combining in situ CO2 measurements and backscatter lidar information , 2007 .

[2]  Jirong Yu,et al.  Side-line tunable laser transmitter for differential absorption lidar measurements of CO2: design and application to atmospheric measurements. , 2008, Applied optics.

[3]  Y. Hirano,et al.  Development of 1.6 microm continuous-wave modulation hard-target differential absorption lidar system for CO2 sensing. , 2009, Optics letters.

[4]  M Harris,et al.  Improved speckle statistics in coherent differential absorption lidar with in-fiber wavelength multiplexing. , 2001, Applied optics.

[5]  P. Drobinski,et al.  Spectral diversity technique for heterodyne Doppler Lidar that uses hard target returns. , 2000, Applied optics.

[6]  Jacques Pelon,et al.  Complementary study of differential absorption lidar optimization in direct and heterodyne detections. , 2006, Applied optics.

[7]  S. Houweling,et al.  Space-borne remote sensing of CO2, CH4, and N2O by integrated path differential absorption lidar: a sensitivity analysis , 2008 .

[8]  M. Wirth,et al.  Development of an OPO system at 1.57 μm for integrated path DIAL measurement of atmospheric carbon dioxide , 2008 .

[9]  J. Caron,et al.  Operating wavelengths optimization for a spaceborne lidar measuring atmospheric CO2. , 2009, Applied optics.

[10]  Jeffrey Y. Beyon,et al.  Coherent differential absorption lidar measurements of CO2. , 2004, Applied optics.

[11]  P. Flamant,et al.  Two-micrometer heterodyne differential absorption lidar measurements of the atmospheric CO2 mixing ratio in the boundary layer. , 2006, Applied optics.

[12]  D. Tratt,et al.  Differential laser absorption spectrometry for global profiling of tropospheric carbon dioxide: selection of optimum sounding frequencies for high-precision measurements. , 2003, Applied optics.

[13]  E. Turiel The Development of Morality , 2007 .