Influence of Micro Threads Alteration on Osseointegration and Primary Stability of Implants: An FEA and In Vivo Analysis in Rabbits.

PURPOSE To describe the early bone tissue response to implants with and without micro threads designed to the full length of an oxidized titanium implant. MATERIALS AND METHODS A pair of two-dimensional finite element models was designed using a computer aided three-dimensional interactive application files of an implant model with micro threads in between macro threads and one without micro threads. Oxidized titanium implants with (test implants n=20) and without (control implants n=20) micro thread were prepared. A total of 12 rabbits were used and each received four implants. Insertion torque while implant placement and removal torque analysis after 4 weeks was performed in nine rabbits, and histomorphometric analysis in three rabbits, respectively. RESULTS Finite element analysis showed less stress accumulation in test implant models with 31Mpa when compared with 62.2 Mpa in control implant model. Insertion and removal torque analysis did not show any statistical significance between the two implant designs. At 4 weeks, there was a significant difference between the two groups in the percentage of new bone volume and bone-to-implant contact in the femur (p< .05); however, not in the tibia. CONCLUSIONS The effect of micro threads was prominent in the femur suggesting that micro threads promote bone formation. The stress distribution supported by the micro threads was especially effective in the cancellous bone.

[1]  C. V. van Blitterswijk,et al.  Reactions of cells at implant surfaces. , 1991, Biomaterials.

[2]  U. Lekholm,et al.  Influence of mono- and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia. , 1996, International journal of oral and maxillofacial surgery.

[3]  J C Keller,et al.  Optimization of surface micromorphology for enhanced osteoblast responses in vitro. , 1993, The International journal of oral & maxillofacial implants.

[4]  T. Albrektsson,et al.  The effect of static bone strain on implant stability and bone remodeling. , 2011, Bone.

[5]  N Meredith,et al.  A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. , 1998, Critical reviews in biomedical engineering.

[6]  L. Sennerby,et al.  Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible. , 2003, Clinical implant dentistry and related research.

[7]  B. Boyan,et al.  Underlying mechanisms at the bone–biomaterial interface. , 1994, Journal of cellular biochemistry.

[8]  Ann Wennerberg,et al.  Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. , 2004, The International journal of prosthodontics.

[9]  B. Le,et al.  Maxillary Sinus Floor Elevation: Review of Anatomy and Two Techniques , 2004, Implant dentistry.

[10]  I. Abrahamsson,et al.  Tissue characteristics at microthreaded implants: an experimental study in dogs. , 2006, Clinical implant dentistry and related research.

[11]  J. Brunski Biomaterials and biomechanics in dental implant design. , 1988, The International journal of oral & maxillofacial implants.

[12]  T Albrektsson,et al.  Current interpretations of the osseointegrated response: clinical significance. , 1993, The International journal of prosthodontics.

[13]  D. Brunette,et al.  The effects of the surface topography of micromachined titanium substrata on cell behavior in vitro and in vivo. , 1999, Journal of biomechanical engineering.

[14]  D. L. Cochran,et al.  Osteoblast-Mediated Mineral Deposition in Culture is Dependent on Surface Microtopography , 2002, Calcified Tissue International.

[15]  P Schärer,et al.  Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study. , 2001, Clinical implant dentistry and related research.

[16]  P. Branemark,et al.  Osseointegration of titanium implants. , 1986, Acta orthopaedica Scandinavica.

[17]  D. Brunette,et al.  The effects of micromachined surfaces on formation of bonelike tissue on subcutaneous implants as assessed by radiography and computer image processing. , 1997, Journal of biomedical materials research.

[18]  J. Davies,et al.  Bone bonding at natural and biomaterial surfaces. , 2007, Biomaterials.

[19]  S. Ferguson,et al.  Biomechanical comparison of the sandblasted and acid-etched and the machined and acid-etched titanium surface for dental implants. , 2002, Journal of biomedical materials research.

[20]  R. Glauser,et al.  Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. , 2003, Clinical implant dentistry and related research.

[21]  Christian Thomsen,et al.  Biomechanical evaluation of macro and micro designed screw-type implants: an insertion torque and removal torque study in rabbits. , 2013, Clinical oral implants research.

[22]  C. V. van Blitterswijk,et al.  Initial bone matrix formation at the hydroxyapatite interface in vivo. , 1995, Journal of biomedical materials research.

[23]  B Rangert,et al.  Influence of implant diameters on the integration of screw implants. An experimental study in rabbits. , 1997, International journal of oral and maxillofacial surgery.

[24]  L A Weinberg,et al.  Therapeutic biomechanics concepts and clinical procedures to reduce implant loading. Part I. , 2001, The Journal of oral implantology.

[25]  L Sennerby,et al.  A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. , 1992, The International journal of oral & maxillofacial implants.

[26]  David L. Cochran,et al.  Osteoblasts generate an osteogenic microenvironment when grown on surfaces with rough microtopographies. , 2003, European cells & materials.

[27]  V A Marker,et al.  Implant materials, designs, and surface topographies: their effect on osseointegration. A literature review. , 2000, The International journal of oral & maxillofacial implants.

[28]  G. Mailath,et al.  Osseous healing characteristics of three different implant types. , 2003, Clinical oral implants research.

[29]  J. Davies,et al.  Understanding peri-implant endosseous healing. , 2003, Journal of dental education.

[30]  C. Kitchen Nonparametric vs parametric tests of location in biomedical research. , 2009, American journal of ophthalmology.

[31]  A. Wennerberg,et al.  Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone. , 2003, The International journal of oral & maxillofacial implants.

[32]  B D Boyan,et al.  Role of material surfaces in regulating bone and cartilage cell response. , 1996, Biomaterials.

[33]  Ann Wennerberg,et al.  A histomorghometric study of screw‐shaped and removal torque titanium implants with three different surface topographies , 1995 .

[34]  S. Hansson,et al.  The implant neck: smooth or provided with retention elements. A biomechanical approach. , 1999, Clinical oral implants research.