Cytotoxicity of Metal and Ceramic Particles in Different Sizes

The wear debris caused by joint prosthesis is well known to induce an inflammation in the peripheral tissue. The authors carried out two kinds of experiments, to clarify the phagocytable size of wear particles and the cytotoxicity of macrophage related to the size and materials. The test materials were Al2O3, SiO2, TiO2 fine particles and Ti-6Al-4V, Co-28Cr-6Mo wear particles. The results showed that the phagocytable particle size was less than 11.9±11.2µm. It appears that the cytotoxicity did not depend on the particle size, even if the particles were phagocytable size. In the relationship between material type and inflammation, damage levels were found to be different between SiO2 and TiO2 particles, even if neither material released metal ions. The cells were damaged more severely by SiO2 particles than by Co-28Cr-6Mo for which the eluted ion could not be ignored (damage levels; SiO2>Co-28Cr-6Mo>Ti-6Al-4V>Al2O3≧TiO2). For these reasons, it was confirmed that there was a factor in addition to the toxicity of the eluted metal ion (i. e., the implant material's corrosion resistance ability), which influenced the inflammation.

[1]  J N Wilson,et al.  Epiphyseal transplantation. A clinical study. , 1966, The Journal of bone and joint surgery. American volume.

[2]  F. Wróblewski,et al.  Lactic Dehydrogenase Activity in Blood.∗ , 1955, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine.

[3]  G K McKee,et al.  Replacement of arthritic hips by the McKee-Farrar prosthesis. , 1966, The Journal of bone and joint surgery. British volume.

[4]  J. Galante,et al.  Metallosis associated with a stable titanium-alloy femoral component in total hip replacement. A case report. , 1990, The Journal of bone and joint surgery. American volume.

[5]  P. Wiles The surgery of the osteo‐arthritic hip , 1958, Clinical orthopaedics and related research.

[6]  P. D. Wilson,et al.  The microscopic anatomy of the bone-cement interface in failed total hip arthroplasties. , 1987, Clinical orthopaedics and related research.

[7]  L. Ceciliani,et al.  Involvement of metal particles in loosening of metal-plastic total hip prostheses , 2004, Archives of orthopaedic and traumatic surgery.

[8]  T. Rae A study on the effects of particulate metals of orthopaedic interest on murine macrophages in vitro. , 1975, The Journal of bone and joint surgery. British volume.

[9]  A. U. Daniels,et al.  Metabolic heat production as a measure of macrophage response to particles from orthopedic implant materials. , 2002, Journal of biomedical materials research.