A review on islanding operation and control for distribution network connected with small hydro power plant

Hydro power generation is the oldest generation and provides the largest contribution among the renewable energy types of generation. In distribution system, most of the distributed generation (DG) is small scale hydro generation of which utilizes the natural flowing water of the river. This generation requires governor and excitation control unit to control and sustain the power generation when subjected to any changes of load behavior. More advanced control strategy is critically expected when considering the recent interest in distribution system to perform islanding operation of DG. Many of the literature have clearly highlighted this issue, but only a few have discussed on the islanding operation of small hydro generation. This paper therefore reviews this topic and relates the discussion with the controller designed for other type of turbines interfaced with synchronous generator. To strengthen the knowledge on islanding operation, the background of islanding is also presented in this paper.

[1]  P. Kundur,et al.  Power system stability and control , 1994 .

[2]  H. Mokhlis,et al.  An adaptive controller of hydro generators for smart grid application in Malaysia , 2010, 2010 International Conference on Power System Technology.

[3]  E. Hesla,et al.  Application of islanding protection for industrial and commercial generators-an IEEE industrial application society working group report , 2006, 59th Annual Conference for Protective Relay Engineers, 2006..

[4]  Peter Crossley,et al.  Control of multiple distributed generators for intentional islanding , 2008 .

[5]  Aidan Foss,et al.  Enhancing small hydro automation using distributed micro-controllers and simulation , 2005 .

[6]  Hasmaini Mohamad,et al.  Islanded operation of UK radial distribution: Earthing strategy , 2009, 2009 44th International Universities Power Engineering Conference (UPEC).

[7]  F. Katiraei,et al.  Planned islanding on rural feeders — utility perspective , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[8]  L. L. J. Mahon,et al.  Diesel Generator Handbook , 1992 .

[9]  Teofana Puleva,et al.  Multiple-model adaptive control of hydro turbine generator with fuzzy TS models , 2008 .

[10]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[11]  Niklas Stråth,et al.  Islanding Detection in Power Systems , 2005 .

[12]  Gareth Harrison,et al.  Integration of Wide-Scale Renewable Resources Into the Power Delivery System, 2009 CIGRE/IEEE PES Joint Symposium , 2009 .

[13]  Peter Crossley,et al.  Islanding detection for distributed generation , 2005 .

[14]  Ieee Standards Board IEEE recommended practice for excitation system models for power system stability studies , 1992 .

[15]  Walmir Freitas,et al.  Performance of ROCOF relays for embedded generation applications , 2005 .

[16]  Andrea Stocco,et al.  Feasibility of adaptive intentional islanding operation of electric utility systems with distributed generation , 2008 .

[17]  Nikos D. Hatziargyriou,et al.  Integrating distributed generation into electric power systems: A review of drivers, challenges and opportunities , 2007 .

[18]  Jovica V. Milanovic,et al.  Comparative Analysis Of Transient Operation of Two Different Embedded Gas Turbine Power Plants , 2002 .

[19]  Wilsun Xu,et al.  A practical method for assessing the effectiveness of vector surge relays for distributed generation applications , 2004, IEEE Transactions on Power Delivery.

[20]  Oliver Paish,et al.  Small hydro power: technology and current status , 2002 .

[21]  M.H. Nehrir,et al.  A Hybrid Islanding Detection Technique Using Voltage Unbalance and Frequency Set Point , 2007, IEEE Transactions on Power Systems.

[22]  Lin Gao,et al.  Analysis of power system frequency responses with hydro turbines incorporating load shedding , 2010, 2010 5th IEEE Conference on Industrial Electronics and Applications.

[23]  Jovica V. Milanovic,et al.  The impact of distributed synchronous generators on quality of electricity supply and transient stability of real distribution network , 2009 .

[24]  C. G. Bright COROCOF: comparison of rate of change of frequency protection. A solution to the detection of loss of mains , 2001 .

[25]  Ilyas Eker The design of robust multi-loop-cascaded hydro governors , 2004, Engineering with Computers.

[26]  J. de Bedout,et al.  Tieline controls in microgrid applications , 2007, 2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability.

[27]  Fang Zheng Peng,et al.  Control for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation , 2011, IEEE Transactions on Industrial Electronics.

[28]  N.W. Miller,et al.  Distributed generation islanding-implications on power system dynamic performance , 2002, IEEE Power Engineering Society Summer Meeting,.

[29]  T.S. Basso,et al.  IEEE 1547 series of standards: interconnection issues , 2004, IEEE Transactions on Power Electronics.

[30]  Xu Rong,et al.  A review on distributed energy resources and MicroGrid , 2008 .

[31]  David M. Laverty,et al.  Management of a multiple-set synchronous island , 2009, 2009 IEEE Power & Energy Society General Meeting.

[32]  Wilsun Xu,et al.  Comparative analysis between ROCOF and vector surge relays for distributed generation applications , 2005, IEEE Transactions on Power Delivery.

[33]  T. Ackermann,et al.  Interaction between distributed generation and the distribution network: operation aspects , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[34]  J. E. Kim,et al.  Islanding detection method of distributed generation units connected to power distribution system , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[35]  Gabriel Garcera,et al.  Analysis of active islanding detection methods for grid-connected microinverters for renewable energy processing , 2010 .

[36]  M. Imai,et al.  New type of islanding detection system for distributed generation based on voltage angle difference between utility network and distributed generation site , 2004 .

[37]  P.A. Crossley,et al.  Transient responses of distributed generators in islanded operation , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[38]  M. Parniani,et al.  Investigating the effects of reactive power on islanding detection , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[39]  Jin Jiang Design of an optimal robust governor for hydraulic turbine generating units , 1995 .

[40]  B. Fox,et al.  Loss of mains detection for embedded generation by system impedance monitoring , 1997 .

[41]  S. Conti,et al.  Generators control systems in intentionally islanded MV microgrids , 2008, 2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion.

[42]  Yu Zhang,et al.  Evaluation of anti-islanding schemes based on nondetection zone concept , 2004, IEEE Transactions on Power Electronics.

[43]  Ehab F. El-Saadany,et al.  Islanding detection of inverter-based distributed generation , 2006 .

[44]  Kwang-Ho Kim,et al.  An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current , 2004 .

[45]  M.R. Iravani,et al.  Power Management Strategies for a Microgrid With Multiple Distributed Generation Units , 2006, IEEE Transactions on Power Systems.

[46]  M. Mohamadian,et al.  Dynamic behavior improvement in a microgrid with multiple DG units using a power sharing approach , 2009, 2009 IEEE Bucharest PowerTech.

[47]  J. R. McDonald,et al.  UK distribution system protection issues , 2007 .

[48]  R. P. Saini,et al.  A review on hydropower plant models and control , 2007 .

[49]  Miles A Redfern,et al.  Protection against loss of utility grid supply for a dispersed storage and generation unit , 1993 .

[50]  Kwang-Ho Kim,et al.  Development of a logical rule-based islanding detection method for distributed resources , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[51]  D. Eager,et al.  The role of risk modelling in the Great Britain transmission planning and operational standards , 2010, 2010 IEEE 11th International Conference on Probabilistic Methods Applied to Power Systems.

[52]  S. P. Chowdhury,et al.  Islanding protection of active distribution networks with renewable distributed generators: A comprehensive survey , 2009 .

[53]  R.J. Best,et al.  Synchronous Islanded Operation of a Diesel Generator , 2007, IEEE Transactions on Power Systems.

[54]  A. Yokoyama,et al.  Reliability Analysis of Distribution System with Distributed Generation Considering Loss of Protection Coordination , 2006, 2006 International Conference on Probabilistic Methods Applied to Power Systems.

[55]  Liuchen Chang,et al.  Recent developments in islanding detection for distributed power generation , 2004, 2004 Large Engineering Systems Conference on Power Engineering (IEEE Cat. No.04EX819).

[56]  A. Cruden,et al.  Experimental testing and model validation of a small-scale generator set for stability analysis , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[57]  A. Dagoumas,et al.  Transient analysis of distributed small hydro generators in a network , 2005, 2005 International Conference on Future Power Systems.

[58]  Ehab F. El-Saadany,et al.  Islanding detection of grid connected distributed generators using TLS-ESPRIT , 2007 .

[59]  S. K. Salman,et al.  New loss of mains detection algorithm for embedded generation using rate of change of voltage and changes in power factors , 2001 .

[60]  Charles Sao,et al.  Control and Power Management of Converter Fed Microgrids , 2008 .

[61]  S. J. Huang,et al.  A Detection Algorithm for Islanding-Prevention of Dispersed Consumer-Owned Storage and Generating Units , 2001, IEEE Power Engineering Review.

[62]  H. Iosfin,et al.  BC Hydro perspective on distribution islanding for customer reliability improvement , 2009, 2009 CIGRE/IEEE PES Joint Symposium Integration of Wide-Scale Renewable Resources Into the Power Delivery System.

[63]  Suryanarayana Doolla,et al.  Automatic generation control of an isolated small-hydro power plant , 2006 .

[64]  P.W. Lehn,et al.  Micro-grid autonomous operation during and subsequent to islanding process , 2005, IEEE Transactions on Power Delivery.

[65]  M. Liserre,et al.  Overview of Anti-Islanding Algorithms for PV Systems. Part I: Passive Methods , 2006, 2006 12th International Power Electronics and Motion Control Conference.

[66]  Wilsun Xu,et al.  Performance of frequency relays for distributed generation protection , 2006, IEEE Transactions on Power Delivery.