Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study

PurposeThe aim of this study was to compare radiological results of total knee arthroplasties (TKAs) performed with patient-specific computed tomography (CT)-based instrumentation and conventional technique. The main study hypothesis was that CT-based patient-specific instrumentation (PSI) increases the accuracy of TKA.MethodsA prospective, randomized controlled trial was carried out between January and December 2011. A group of 112 patients who met the inclusion and exclusion criteria were enrolled in this study and randomly assigned to an experimental or control group. The experimental group comprised 52 patients operated on with the aid of the Signature™ CT-based implant positioning system. The control group consisted of 60 patients operated on using conventional instrumentation. The radiographic evaluation of implant positioning and overall coronal alignment was performed 12 months after the surgery by using standing anteroposterior radiographs of the entire lower limb and standard lateral radiographs.ResultsOf the 112 patients initially enrolled for the study, 95 were included in the subsequent analyses. There were no statistically significant differences between groups in respect to coronal and sagittal component positioning and overall coronal alignment, except for frontal tibial component positioning. For this parameter, better results were obtained in the control group, with borderline statistical significance.ConclusionsOur study did not reveal superiority of the CT-based PSI system over conventional instrumentation. Further high-quality investigations of patient-specific systems are absolutely indispensable to assess their utility for TKA. In our opinion, the surgeon applying PSI technology is required to have advanced knowledge and considerable experience with the conventional method.

[1]  P. Sharkey,et al.  Why Are Total Knee Arthroplasties Failing Today? , 2002 .

[2]  K. Mak,et al.  Comparison of Total Knee Arthroplasty Using Computer-Assisted Navigation versus Conventional Guiding Systems: A Prospective Study , 2009, Journal of orthopaedic surgery.

[3]  J. Bellemans,et al.  A new surgical technique for medial collateral ligament balancing: multiple needle puncturing. , 2010, The Journal of arthroplasty.

[4]  B. Boonen,et al.  Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[5]  S. Kurtz,et al.  Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. , 2007, The Journal of bone and joint surgery. American volume.

[6]  S. Fucentese,et al.  Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[7]  J. Dohle,et al.  Achsvermessung bei Knie-TEP: Ganzbeinstandaufnahme als Golden Standard , 2002 .

[8]  Sébastien Lustig,et al.  Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. , 2013, The Journal of arthroplasty.

[9]  A. Ferretti,et al.  Patient-specific instruments in total knee arthroplasty , 2014, International Orthopaedics.

[10]  A. Lombardi,et al.  Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA , 2012, Clinical orthopaedics and related research.

[11]  K. Daniilidis,et al.  A comparison of conventional and patient-specific instruments in total knee arthroplasty , 2014, International Orthopaedics.

[12]  B. Boonen,et al.  Preliminary experience with the patient-specific templating total knee arthroplasty , 2012, Acta orthopaedica.

[13]  R. Barrack,et al.  Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty? , 2012, Clinical orthopaedics and related research.

[14]  Thomas R Jenkyn,et al.  Radiographic Measures of Knee Alignment in Patients with varus Gonarthrosis , 2007, The American journal of sports medicine.

[15]  J. Mason,et al.  In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty. , 2014, The Journal of arthroplasty.

[16]  Johan Bellemans,et al.  Patient-specific Guides Do Not Improve Accuracy in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial , 2013, Clinical orthopaedics and related research.

[17]  S. Kurtz,et al.  International survey of primary and revision total knee replacement , 2011, International Orthopaedics.

[18]  T. Fehring,et al.  Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. , 2007, The Journal of arthroplasty.

[19]  H. Dossett,et al.  Kinematically versus mechanically aligned total knee arthroplasty. , 2012, Orthopedics.

[20]  P. Sharkey,et al.  Insall Award paper. Why are total knee arthroplasties failing today? , 2002, Clinical orthopaedics and related research.

[21]  Andrea Ferretti,et al.  Evaluation of the accuracy of a patient-specific instrumentation by navigation , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[22]  Michael A. Mont,et al.  Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment , 2009, International Orthopaedics.

[23]  Christopher L. Peters,et al.  Patient-specific Total Knee Arthroplasty Required Frequent Surgeon-directed Changes , 2013, Clinical orthopaedics and related research.

[24]  Johan Bellemans,et al.  Patient-specific instruments: industry’s innovation with a surgeon’s interest , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[25]  Andrew D Pearle,et al.  Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. , 2013, The Knee.

[26]  Joanne B. Adams,et al.  Patient-specific approach in total knee arthroplasty. , 2008, Orthopedics.

[27]  J. Lonner,et al.  Effect of Rotation and Knee Flexion on Radiographic Alignment in Total Knee Arthroplasties , 1996, Clinical orthopaedics and related research.

[28]  Thomas R Jenkyn,et al.  Foot rotational effects on radiographic measures of lower limb alignment. , 2006, Canadian journal of surgery. Journal canadien de chirurgie.

[29]  R. Morris,et al.  Coronal alignment after total knee replacement. , 1991, The Journal of bone and joint surgery. British volume.

[30]  S. Lee,et al.  Is TKA Using Patient-specific Instruments Comparable to Conventional TKA? A Randomized Controlled Study of One System , 2013, Clinical orthopaedics and related research.

[31]  M. Ritter,et al.  Postoperative alignment of total knee replacement. Its effect on survival. , 1994, Clinical orthopaedics and related research.

[32]  M. Langenbach,et al.  [Determination of the axis after totalendoprosthesis of the knee: functional X-ray photography as golden standard]. , 2002, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[33]  M. Lohman,et al.  Comparison of Standard Anteroposterior Knee and Hip-to-Ankle Radiographs in Determining the Lower Limb and Implant Alignment after Total Knee Arthroplasty , 2009, Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society.

[34]  K. Daniilidis,et al.  Frontal plane alignment after total knee arthroplasty using patient-specific instruments , 2012, International Orthopaedics.

[35]  M Richter,et al.  Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method , 2006, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[36]  Tao Cheng,et al.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[37]  Claudio Belvedere,et al.  Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement , 2014, Knee Surgery, Sports Traumatology, Arthroscopy.

[38]  J O Galante,et al.  Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[39]  J. Argenson,et al.  Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.