Validation of simple and robust protocols for high‐resolution lung proton MRI in mice

One fundamental limitation of spatial resolution for in vivo MR lung imaging is related to motion in the thoracic cavity. To overcome this limitation, several methods have been proposed, including scan‐synchronous ventilation and the cardiac gating approach. However, with cardiac and ventilation triggered techniques, the use of a predetermined and constant sequence repetition time is not possible, resulting in variable image contrast. In this study, the potential of two “constant repetition time” approaches based on retrospective self‐gating and signal averaging were investigated for lung imaging. Image acquisitions were performed at a very short echo time for visualization of the lung structures and the parenchyma. Highly spatially resolved images acquired using retrospective self‐gating, signal averaging technique and conventional cardiorespiratory gating are presented and compared. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  S. Neubauer,et al.  Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields , 2004, Journal of magnetic resonance imaging : JMRI.

[2]  L W Hedlund,et al.  MR microimaging of the lung using volume projection encoding , 1997, Magnetic resonance in medicine.

[3]  Pierre Croisille,et al.  Cardiac and respiratory double self‐gated cine MRI in the mouse at 7 T , 2006, Magnetic resonance in medicine.

[4]  P. Jakob,et al.  Lung imaging under free‐breathing conditions , 2009, Magnetic resonance in medicine.

[5]  J. Fozard,et al.  MRI of lung parenchyma in rats and mice using a gradient‐echo sequence , 2001, NMR in biomedicine.

[6]  J R MacFall,et al.  MR microscopy of the rat lung using projection reconstruction , 1993, Magnetic resonance in medicine.

[7]  N. Beckman,et al.  In Vivo MR Techniques in Drug Discovery and Development , 2006 .

[8]  H. Alsaid,et al.  Retrospective cine 3He ventilation imaging under spontaneous breathing conditions: a non‐invasive protocol for small‐animal lung function imaging , 2007, NMR in biomedicine.

[9]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[10]  L W Hedlund,et al.  MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging. , 2000, Magnetic resonance imaging.

[11]  J. Fozard,et al.  Capsaicin‐induced mucus secretion in rat airways assessed in vivo and non‐invasively by magnetic resonance imaging , 2007, British journal of pharmacology.

[12]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[13]  C J Bergin,et al.  Magnetic resonance imaging of lung parenchyma , 1993, Journal of thoracic imaging.

[14]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[15]  G Allan Johnson,et al.  Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents , 2005, Magnetic resonance in medicine.

[16]  V Rasche,et al.  Motion compensated projection reconstruction , 1999, Magnetic resonance in medicine.

[17]  G Laub,et al.  Coronary artery imaging: 3D segmented k‐space data acquisition with multiple breath‐holds and real‐time slab following , 2001, Journal of magnetic resonance imaging : JMRI.

[18]  Eiichi Fukushima,et al.  Short data‐acquisition times improve projection images of lung tissue , 2007, Magnetic resonance in medicine.

[19]  Anja C S Brau,et al.  Cine magnetic resonance microscopy of the rat heart using cardiorespiratory‐synchronous projection reconstruction , 2004, Journal of magnetic resonance imaging : JMRI.

[20]  J. Fozard,et al.  Lung MRI in Small Rodents as a Tool for the Evaluation of Drugs in Models of Airways Diseases , 2006 .

[21]  Andrew C Larson,et al.  Preliminary investigation of respiratory self‐gating for free‐breathing segmented cine MRI , 2005, Magnetic resonance in medicine.

[22]  P. Hockings,et al.  Measurement of MR signal and T2* in lung to characterize a tight skin mouse model of emphysema using single‐point imaging , 2007, Journal of magnetic resonance imaging : JMRI.

[23]  J. Fozard,et al.  Proton MRI as a noninvasive tool to assess elastase‐induced lung damage in spontaneously breathing rats , 2006, Magnetic resonance in medicine.

[24]  J. Fozard,et al.  Pulmonary edema induced by allergen challenge in the rat: Noninvasive assessment by magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[25]  L W Hedlund,et al.  Registered 1H and 3He magnetic resonance microscopy of the lung , 2001, Magnetic resonance in medicine.

[26]  Eric C Frey,et al.  Development of a 4-D digital mouse phantom for molecular imaging research. , 2004, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[27]  Yannick Crémillieux,et al.  Lung MRI for experimental drug research. , 2007, European journal of radiology.

[28]  J. Fozard,et al.  In vivo pharmacological evaluation of compound 48/80‐induced airways oedema by MRI , 2008, British journal of pharmacology.