Effects of amplitude-dependent damping and time constant on wind-induced responses of super tall building

Full-scale measurements of wind-induced responses of a 79-storey tall building, Di Wang Tower, were conducted during the passages of several typhoons. The amplitude-dependent damping ratios of the super tall building were obtained from the measurements. A Monte Carlo simulation procedure was developed in this study to generate fluctuating along-wind and across-wind forces acting on this building. The wind-induced responses of Di Wang Tower were numerically evaluated in time domain on the basis of the generated fluctuating wind forces and the established finite element model of the building. The predicted dynamic responses of the building using the actual amplitude-dependent damping characteristics were compared to those computed with constant damping parameters assumed by the structural designers to evaluate the adequacy of current design practices and to investigate the effect of amplitude-dependent damping on the wind-induced responses. Finally, the effect of time constant on the wind-induced responses of Di Wang Tower was studied by comparing the time domain computational results with those from conventional spectral analysis method. Some of the research findings resulted from this combined experimental and numerical study are expected to be of interest and practical use to professionals and researchers involved in the design and analysis of super tall buildings.

[1]  Emil Simiu,et al.  Wind effects on structures : fundamentals and applications to design , 1996 .

[2]  R. Clough,et al.  Dynamics Of Structures , 1975 .

[3]  Qiusheng Li,et al.  Correlation of dynamic characteristics of a super‐tall building from full‐scale measurements and numerical analysis with various finite element models , 2004 .

[4]  A. P. Jeary,et al.  Damping in tall buildings—a mechanism and a predictor , 1986 .

[5]  Q S Li BEngSc MEngSc PhD MIEAust Evaluation of Wind-Induced Vibration Of Tall Buildings and Reliability Analysis: A Case Study , 2000 .

[6]  Qiusheng Li,et al.  Serviceability of a 79-storey tall building under typhoon conditions , 2005 .

[7]  Dikai Liu,et al.  Damping in buildings : its neural network model and AR model , 2000 .

[8]  Jun Kanda,et al.  Proposed formulae for the power spectral densities of fluctuating lift and torque on rectangular 3-D cylinders , 1993 .

[9]  Masanobu Shinozuka,et al.  Stochastic Methods in Structural Dynamics , 1987 .

[10]  Y. Tamura,et al.  Evaluation of amplitude-dependent damping and natural frequency of buildings during strong winds , 1996 .

[11]  A. P. Jeary,et al.  Full scale measurements of wind effects on tall buildings , 1998 .

[12]  Qiusheng Li,et al.  Full-scale monitoring of typhoon effects on super tall buildings , 2005 .

[13]  Yukio Tamura,et al.  Wind load and wind-induced response estimations in the Recommendations for Loads on Buildings, AIJ 1993 , 1996 .

[14]  M. Shinozuka,et al.  Digital simulation of random processes and its applications , 1972 .

[15]  A. P. Jeary,et al.  The effect of amplitude-dependent damping on wind-induced vibrations of a super tall building , 2003 .

[16]  Bo Liang,et al.  Simulation of wind-induced lateral-torsional motion of tall buildings , 1997 .

[17]  Ming Gu,et al.  Mathematical model of acrosswind dynamic loads on rectangular tall buildings , 2001 .

[18]  Alan G. Davenport,et al.  Gust Loading Factors , 1967 .

[19]  Po-Chien Lu,et al.  Wind loads on square cylinder in homogeneous turbulent flows , 1992 .

[20]  R. I. Harris Proceedings of the Fourth International Conference on Wind Effects on Buildings and Structures: edited by K.J. Eaton, Cambridge University Press, 1977, £ 25.00 , 1977 .

[21]  Paolo Spinelli,et al.  Artificial Wind Generation and Structural Response , 1987 .

[22]  J. W. Tedesco,et al.  Structural Dynamics: Theory and Applications , 1998 .

[23]  Yiqing Xiao,et al.  Field measurements of typhoon effects on a super tall building , 2004 .

[24]  Zhengnong Li,et al.  Wind tunnel and full-scale study of wind effects on China’s tallest building , 2006 .

[25]  Yukio Tamura,et al.  Damping Evaluation Using Full-Scale Data of Buildings in Japan , 2003 .

[26]  You-Lin Xu,et al.  Modal identification of Di Wang Building under Typhoon York using the Hilbert–Huang transform method , 2003 .

[27]  J. D. Holmes,et al.  Wind Loading of Structures , 2001 .

[28]  Yukio Tamura,et al.  Response analyses on along-wind and across-wind vibrations of tall buildings in time domain , 1993 .