Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) Using Corneal Donor Tissue Not Acceptable for Use in Penetrating Keratoplasty as a Result of Anterior Stromal Scars, Pterygia, and Previous Corneal Refractive Surgical Procedures

Purpose: The purpose of this study was to evaluate outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) using anterior stromal flawed (ASF) donor corneas that were unsuitable for use in full-thickness penetrating keratoplasty as a result of stromal scars, pterygia, or previous corneal refractive surgery and to compare results with DSAEK using standard tissue. Methods: We conducted a review of our initial 42 (19 with 6-month follow up) consecutive DSAEK surgeries using ASF tissue compared with 357 (199 with 6-month follow up) time-matched controls using standard tissue. Intraoperative and perioperative complications, including dislocations and primary graft failures, were compared. Six-month best spectacle-corrected vision, incidence of rejection episodes, postoperative refractive astigmatism, keratometric values, pre- and postoperative topography-derived surface asymmetry index, and surface regularity index were compared. Results: One surgeon-cut ASF tissue was perforated before surgery and was discarded. No surgeon-cut standard tissue was perforated. No intraoperative complications and no episodes of primary graft failure or pupillary block glaucoma occurred in either group. One (2.4%) postoperative graft dislocation and one (5.2%) graft rejection episode occurred in the study group. There were 10 (2.8%) dislocations and 8 (2.2%) graft rejection in the controls. A statistically similar significant improvement in best spectacle-corrected vision occurred in both groups. Corneal topography, pachymetry, and manifest astigmatism were not significantly different between groups. Conclusion: Postoperative results of DSAEK using donor tissue excluded from use in penetrating keratoplasty as a result of stromal flaws are equivalent to results using standard donor tissue. Central corneal thickness measurements should be performed before cutting to avoid tissue perforation. The use of ASF tissue for DSAEK will expand the cornea donor pool.

[1]  Christopher G. Stoeger,et al.  Endothelial Keratoplasty: The Influence of Insertion Techniques and Incision Size on Donor Endothelial Survival , 2009, Cornea.

[2]  M. Terry,et al.  Endothelial Keratoplasty: The Influence of Preoperative Donor Endothelial Cell Densities on Dislocation, Primary Graft Failure, and 1-Year Cell Counts , 2008, Cornea.

[3]  W. Culbertson,et al.  Complications of Descemet's stripping with automated endothelial keratoplasty: survey of 118 eyes at One Institute. , 2008, Ophthalmology.

[4]  I. Bahar,et al.  Comparison of posterior lamellar keratoplasty techniques to penetrating keratoplasty. , 2008, Ophthalmology.

[5]  M. Terry,et al.  Endothelial Keratoplasty: A Simplified Technique to Minimize Graft Dislocation, Iatrogenic Graft Failure, and Pupillary Block , 2008 .

[6]  M. Terry,et al.  Descemet-Stripping Automated Endothelial Keratoplasty: Six-month Results in a Prospective Study of 100 Eyes , 2008, Cornea.

[7]  F. Price,et al.  Endothelial cell loss after descemet stripping with endothelial keratoplasty influencing factors and 2-year trend. , 2008, Ophthalmology.

[8]  M. Terry,et al.  Endothelial cell loss after Descemet's stripping endothelial keratoplasty in a large prospective series. , 2008, Ophthalmology.

[9]  M. Terry,et al.  Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications. , 2008, Ophthalmology (Rochester, Minn.).

[10]  A. Kuo,et al.  Novel delivery method to reduce endothelial injury in descemet stripping automated endothelial keratoplasty. , 2008, American journal of ophthalmology.

[11]  D. Rootman,et al.  Slit-lamp technique of draining interface fluid following Descemet’s stripping endothelial keratoplasty , 2007, British Journal of Ophthalmology.

[12]  William J Dupps,et al.  Visual Acuity, Refractive Error, and Endothelial Cell Density Six Months After Descemet Stripping and Automated Endothelial Keratoplasty (DSAEK) , 2007, Cornea.

[13]  D. Covert,et al.  New triple procedure: Descemet's stripping and automated endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation. , 2007, Ophthalmology.

[14]  Christopher G. Stoeger,et al.  Endothelial Keratoplasty Using Donor Tissue Not Suitable for Full-Thickness Penetrating Keratoplasty , 2007, Cornea.

[15]  W. Dupps,et al.  Use of an air-fluid exchange system to promote graft adhesion during Descemet's stripping automated endothelial keratoplasty. , 2007, Journal of cataract and refractive surgery.

[16]  M. Qureshi,et al.  Experience and 12-Month Results of Descemet-Stripping Endothelial Keratoplasty (DSEK) with a Small-Incision Technique , 2007, Cornea.

[17]  W. Dupps,et al.  Simple technique to unfold the donor corneal lenticule during Descemet's stripping and automated endothelial keratoplasty. , 2007, Journal of cataract and refractive surgery.

[18]  M. B. Goren The Eye Bank Association of America. , 2006, Comprehensive ophthalmology update.

[19]  Marianne O Price,et al.  Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges and techniques to enhance donor adherence , 2006, Journal of cataract and refractive surgery.

[20]  M. Terry,et al.  Deep lamellar endothelial keratoplasty visual acuity, astigmatism, and endothelial survival in a large prospective series. , 2005, Ophthalmology.

[21]  F. Price,et al.  Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. , 2005, Journal of refractive surgery.

[22]  M. Terry,et al.  Small-incision deep lamellar endothelial keratoplasty (DLEK): six-month results in the first prospective clinical study. , 2005, Cornea.

[23]  E. Pels,et al.  A surgical technique for posterior lamellar keratoplasty. , 1998, Cornea.