Accuracy of spectral Doppler flow and tissue velocity measurements in ultrasound systems.

[1]  K. Isaaz,et al.  Doppler echocardiographic measurement of low velocity motion of the left ventricular posterior wall. , 1989, The American journal of cardiology.

[2]  J. Hossack,et al.  Testing ultrasonic pulsed Doppler instruments with a physiologic string phantom. , 1990, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[3]  E. S. Furgason,et al.  The Dependence of Ultrasound Doppler Bandwidth on Beam Geometry , 1980, IEEE Transactions on Sonics and Ultrasonics.

[4]  Johan M. Thijssen,et al.  Performance testing of medical echo/Doppler equipment. , 2002 .

[5]  A Goldstein,et al.  Performance tests of Doppler ultrasound equipment with a string phantom. , 1991, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[6]  J. Jensen Estimation of Blood Velocities Using Ultrasound: A Signal Processing Approach , 1996 .

[7]  A. Duerinckx,et al.  Assurance of consistent peak-velocity measurements with a variety of duplex Doppler instruments. , 1990, Radiology.

[8]  P. Hoskins,et al.  Accuracy of maximum velocity estimates made using Doppler ultrasound systems. , 1996, The British journal of radiology.

[9]  T Loupas,et al.  Spectral and color Doppler sonographic applications of a new test object with adjustable moving target spacing. , 1996, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[10]  N. Thomas,et al.  The impact of theoretical errors on velocity estimation and accuracy of duplex grading of carotid stenosis. , 2002, Ultrasound in medicine & biology.

[11]  V L Newhouse,et al.  On the spectral properties of Doppler thread phantoms. , 1994, Ultrasound in medicine & biology.

[12]  R S Cobbold,et al.  Sources of error in maximum velocity estimation using linear phased-array Doppler systems with steady flow. , 2001, Ultrasound in medicine & biology.

[13]  G. Sutherland,et al.  Pulsed doppler myocardial imaging. A new approach to regional longitudinal function? , 2000, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[14]  P R Hoskins Choice of moving target for a string phantom: II. On the performance testing of Doppler ultrasound systems. , 1994, Ultrasound in medicine & biology.

[15]  R. Gill Measurement of blood flow by ultrasound: accuracy and sources of error. , 1985, Ultrasound in medicine & biology.

[16]  J. Felmlee,et al.  Blood flow velocity measurements: a comparison of 25 clinical ultrasonographic units. , 1995, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[17]  Andrew R. Walker,et al.  Evaluating doppler devices using a moving string test target , 1982, Journal of clinical ultrasound : JCU.

[18]  A Goldstein Effect of tank liquid acoustic velocity on Doppler string phantom measurements. , 1991, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[19]  Per Ask,et al.  Blood flow measurements , 1999 .

[20]  A Fenster,et al.  A velocity evaluation phantom for colour and pulsed Doppler instruments. , 1992, Ultrasound in medicine & biology.