Development of Positron Emission Tomography With Wobbling and Zooming for High Sensitivity and High-Resolution Molecular Imaging
暂无分享,去创建一个
Zang-Hee Cho | Young-Bo Kim | Dae-Hyuk Kwon | Young-Don Son | Yo-Han Joo | Hang-Keun Kim | Yong Choi | Jong Beom Ra
[1] C. J. Thompson,et al. Real-Time Data Rebinning in PET to Obtain Uniformly Sampled Projections , 1985, IEEE Transactions on Nuclear Science.
[2] Shuping Xie,et al. A dedicated PET system for human brain and head/neck imaging , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).
[3] Quanzheng Li,et al. National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner , 2016, The Journal of Nuclear Medicine.
[4] Alan C. Evans,et al. Performance evaluation of the PC-2048: a new 15-slice encoded-crystal PET scanner for neurological studies. , 1991, IEEE transactions on medical imaging.
[5] E. Hoffman,et al. A positron-emission transaxial tomograph for nuclear imaging (PETT). , 1975, Radiology.
[6] C. Knoess,et al. The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new High Resolution Research Tomograph , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).
[7] Z H Cho,et al. Positron ranges obtained from biomedically important positron-emitting radionuclides. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[8] Z. Cho,et al. Bismuth germanate as a potential scintillation detector in positron cameras. , 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[9] Thomas Beyer,et al. Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard , 2018, The Journal of Nuclear Medicine.
[10] E. Hoffman,et al. Application of annihilation coincidence detection to transaxial reconstruction tomography. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[11] Simon R. Cherry,et al. Techniques to improve the spatial sampling of MicroPET-a high resolution animal PET tomograph , 2000 .
[12] Geor Bakker,et al. 123I-Iododexetimide Preferentially Binds to the Muscarinic Receptor Subtype M1 In Vivo , 2015, The Journal of Nuclear Medicine.
[13] R. Muenchausen,et al. Crystal growth and optical characterization of cerium-doped Lu1.8Y0.2SiO5 , 2000 .
[14] Zang-Hee Cho,et al. A new approach to very high resolution mini-brain PET using a small number of large detectors , 1990 .
[15] J. K. Chan,et al. Circular Ring Transverse Axial Positron Camera for 3-Dimensional Reconstruction of Radionuclides Distribution , 1976, IEEE Transactions on Nuclear Science.
[16] Jong Beom Ra,et al. High-resolution circular ring positron tomograph with dichotomic sampling: Dichotom-I , 1983 .
[17] Z. Cho,et al. General views on 3-D image reconstruction and computerized transverse axial tomography , 1974 .
[18] S. Y. Lee,et al. A New Sampling Scheme for the Ring Positron Camera: Dichotomic Ring Sampling , 1981, IEEE Transactions on Nuclear Science.
[19] Nan Zhang,et al. Basic imaging performance characteristics of a variable field of view PET camera using quadrant sharing detector design , 1998 .
[20] Michel M. Ter-Pogossian,et al. Performance Study of PETT VI, a Positron Computed Tomograph with 288 Cesium Fluoride Detectors , 1982, IEEE Transactions on Nuclear Science.
[21] Jong Beom Ra,et al. A New Sampling Scheme for the Ring Positron Camera: Dichotomic Ring Sampling , 1981 .
[22] C J Thompson,et al. Dependence of the coincidence aperture function of narrow BGO crystals on crystal shape and light encoding schemes. , 1986, Physics in medicine and biology.
[23] M Honda,et al. Development of a Brain PET System, PET-Hat: A Wearable PET System for Brain Research , 2011, IEEE Transactions on Nuclear Science.
[24] H. Zaidi,et al. Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system , 2011, Physics in medicine and biology.
[25] Zang-Hee Cho,et al. A fusion PET–MRI system with a high‐resolution research tomograph‐PET and ultra‐high field 7.0 T‐MRI for the molecular‐genetic imaging of the brain , 2008, Proteomics.
[26] Thomas Beyer,et al. Performance evaluation of the Biograph mCT Flow PET/CT system according to the NEMA NU2-2012 standard , 2015, EJNMMI Physics.
[27] J. Uribe,et al. Studies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System , 2017, The Journal of Nuclear Medicine.
[28] Julien Bert,et al. The MINDVIEW project: First results , 2018, European Psychiatry.
[29] Yong Choi,et al. Development of a position decoder circuit for PET consisting of GAPD arrays , 2010 .
[30] Zang-Hee Cho,et al. Wobbling and LSF-based maximum likelihood expectation maximization reconstruction for wobbling PET , 2016 .
[31] D. Townsend,et al. Method for transforming CT images for attenuation correction in PET/CT imaging. , 2006, Medical physics.
[32] Klaus Wienhard,et al. The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph , 2000 .
[33] David W. Townsend,et al. An investigation of factors affecting detector and geometric correction in normalization of 3-D PET data , 1995 .
[34] M. Singh,et al. Performance and Evaluation of the Circular Ring Transverse Axial Positron Camera (CRTAPC) , 1977, IEEE Transactions on Nuclear Science.