Numerical simulation and experimental investigation of a topologically optimized compliant microgripper
暂无分享,去创建一个
[1] Zhaowei Zhong,et al. Investigation of a gripping device actuated by SMA wire , 2007 .
[2] Yong Mo Moon,et al. DESIGN OF LARGE-DISPLACEMENT COMPLIANT JOINTS , 2005 .
[3] Kristofer S. J. Pister,et al. Analysis of closed-loop control of parallel-plate electrostatic microgrippers , 1994, Proceedings of the 1994 IEEE International Conference on Robotics and Automation.
[4] Shuichi Miyazaki,et al. SMA microgripper with integrated antagonism , 2000 .
[5] A. Nikoobin,et al. DERIVING AND ANALYZING THE EFFECTIVE PARAMETERS IN MICROGRIPPERS PERFORMANCE (RESEARCH NOTE) , 2012 .
[6] Ren-Jung Chang,et al. Self-Biased-SMA Drive PU Microgripper with Force Sensing in Visual Servo , 2013 .
[7] Eric R. Marsh,et al. A unified geometric model for designing elastic pivots , 2008 .
[8] Sun Jun,et al. Finite element analysis of a IBM suspension integrated with a PZT microactuator , 2002 .
[9] Manfred Kohl,et al. SMA microgripper system , 2002 .
[10] Huei-Huang Lee,et al. Finite element simulations with ANSYS workbench 16 , 2015 .
[11] Lena Zentner,et al. The influence of asymmetric flexure hinges on the axis of rotation , 2011 .
[12] Nicolae Lobontiu,et al. Design of symmetric conic-section flexure hinges based on closed-form compliance equations , 2002 .
[13] Nicolae Lobontiu,et al. Parabolic and hyperbolic flexure hinges: flexibility, motion precision and stress characterization based on compliance closed-form equations , 2002 .
[14] G. K. Ananthasuresh,et al. Miniature Compliant Grippers With Vision-Based Force Sensing , 2010, IEEE Transactions on Robotics.
[15] Zhaowei Zhong,et al. Failure analysis of ultrasonic pitting and carbon voids on magnetic recording disks , 2004 .
[16] Zhaowei Zhong,et al. Development of a gripper using SMA wire , 2006 .
[17] Robert Lewis Reuben,et al. A scalable syringe-actuated microgripper for biological manipulation , 2012 .
[18] Wensyang Hsu,et al. An electro-thermally and laterally driven polysilicon microactuator , 1997 .
[19] Wen J. Li,et al. A thermally actuated polymer micro robotic gripper for manipulation of biological cells , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).
[20] L. Montelius,et al. Customizable nanotweezers for manipulation of free-standing nanostructures , 2001, Proceedings of the 2001 1st IEEE Conference on Nanotechnology. IEEE-NANO 2001 (Cat. No.01EX516).
[21] Che-Min Lin,et al. A Self-Sensing Microgripper Module With Wide Handling Ranges , 2011, IEEE/ASME Transactions on Mechatronics.
[22] P. Dario,et al. Micro-systems in biomedical applications , 2000 .
[23] M. Bendsøe,et al. Topology Optimization: "Theory, Methods, And Applications" , 2011 .
[24] Benjamin J. Southwell,et al. Human Object Recognition Using Colour and Depth Information from an RGB-D Kinect Sensor , 2013 .
[25] Maria Chiara Carrozza,et al. The development of a LIGA-microfabricated gripper for micromanipulation tasks , 1998 .
[26] E Gerhard,et al. Design and fabrication of a current-pulse-excited bistable magnetic microactuator , 1997 .
[27] Sridhar Kota,et al. Synthesis of Planar, Compliant Four-Bar Mechanisms for Compliant-Segment Motion Generation four-bar mechanisms treated in previous works consisted of at least one rigid , 2001 .
[28] R. Muller,et al. Silicon-processed overhanging microgripper , 1992 .
[29] Dominiek Reynaerts,et al. Pneumatic and hydraulic microactuators: a review , 2010 .
[30] Alberto Cardona,et al. Inverse finite element method for large-displacement beams , 2010 .
[31] Ivo W. Rangelow,et al. Electrostatically driven microgripper , 2002 .
[32] Zhaowei Zhong,et al. Flying height deviations in glide height tests , 2003 .
[33] David Zhang,et al. Closed-form compliance equations of filleted V-shaped flexure hinges for compliant mechanism design , 2010 .
[34] G. K. Ananthasuresh,et al. Miniature Compliant Grippers with Force-Sensing , 2009 .
[35] Zhaowei Zhong,et al. A microgripper using piezoelectric actuation for micro-object manipulation , 2007 .
[36] C J Shih,et al. A two-stage topological optimum design for monolithic compliant microgripper integrated with flexure hinges , 2006 .