Evanescent wave immunoprobe with high bivalent antibody activity

Abstract We have determined the kinetic response of an evanescent wave optical fibre immunosensor and its absolute sensitivity. Using both kinetic methods and optical determinations of bound antigen, we infer that there are 2·4 × 10 11 active antibodies per cm 2 probe area. We estimate that 75% of the active antibodies are in the bivalent form, with both binding site capable of binding antigen. Using the kinetic data and optical measurements of the number of antigens bound to the fibre, we estimate that the unstirred dead layer thickness next to the fibre surface in the stirred solution, across which the antigens must diffuse, is 55 μm. Approximately 10 9 FITC labelled antigens are necessary to achieve a threshold signal, defined as 1% of the signal obtained when the fibre is saturated with antigen.

[1]  H. Berg,et al.  Physics of chemoreception. , 1977, Biophysical journal.

[2]  J. Kop,et al.  The role of intrinsic binding rate and transport rate in the adsorption of prothrombin, albumin, and fibrinogen to phospholipid bilayers , 1986 .

[3]  Frances S. Ligler,et al.  Chemistry and Technology of Evanescent Wave Biosensors , 1991 .

[4]  Ivar Giaever,et al.  Adsorption of ferritin , 1980 .

[5]  Tomas Hirschfeld,et al.  Effect of numerical aperture on signal level in cylindrical waveguide evanescent fluorosensors. , 1987, Applied optics.

[6]  W. Little,et al.  A new immunoassay based on fluorescence excitation by internal reflection spectroscopy. , 1975, Journal of immunological methods.

[7]  Frances S. Ligler,et al.  The Effect of Tapering the Optical Fiber on Evanescent Wave Measurements , 1992 .

[8]  Donald L. Wise,et al.  Biosensors with Fiberoptics , 1991, Contemporary Instrumentation and Analysis.

[9]  Sandra F. Feldman,et al.  Determination of the kinetic response and absolute sensitivity of a fiber-optic immunoassay , 1994, Other Conferences.

[10]  R. M. Sutherland,et al.  Optical detection of antibody-antigen reactions at a glass-liquid interface. , 1984, Clinical chemistry.

[11]  Walter F. Love,et al.  Optical Characteristics of Fiberoptic Evanescent Wave Sensors , 1991 .

[12]  Walter F. Love,et al.  Theoretical considerations for evanescent-wave immunosensors in biomedical applications , 1992, Other Conferences.

[13]  J M Calvert,et al.  Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces. , 1989, Analytical biochemistry.

[14]  Frances S. Ligler,et al.  Evanescent-wave fiber optic biosensor: challenges for real-world sensing , 1993, Other Conferences.

[15]  Z. Priel,et al.  Kinetic model for the irreversible adsorption of macromolecules at a liquid-solid interface , 1985 .

[16]  P. B. Sackett Effect of fluorescence observation geometry on lifetime measurement, including the development of an approximation to the detector collection efficiency integral. , 1972, Applied optics.

[17]  Frances S. Ligler,et al.  Fiber Optic-Based Immunosensors: A Progress Report , 1989, Photonics West - Lasers and Applications in Science and Engineering.