Bioanalytical LC-MS/MS of protein-based biopharmaceuticals.

Biotechnology increasingly delivers highly promising protein-based biopharmaceutical candidates to the drug development funnel. For successful biopharmaceutical drug development, reliable bioanalytical methods enabling quantification of drugs in biological fluids (plasma, urine, tissue, etc.) are required to generate toxicokinetic (TK), pharmacokinetic (PK), and bioavailability data. A clear observable trend is that liquid chromatography coupled to (tandem) mass spectrometry (LC-MS(/MS)) is more and more replacing ligand binding assays (LBA) for the bioanalytical determination of protein-based biopharmaceuticals in biological matrices, mainly due to improved selectivity and linear dynamic ranges. Practically all MS-based quantification methods for protein-based biopharmaceuticals traditionally rely on (targeted) proteomic techniques and include "seven critical factors": (1) internal standardization, (2) protein purification, (3) enzymatic digestion, (4) selection of signature peptide(s), (5) peptide purification, (6) liquid chromatographic separation and (7) mass spectrometric detection. For this purpose, the variety of applied strategies for all "seven critical factors" in current literature on MS-based protein quantification have been critically reviewed and evaluated. Special attention is paid to the quantification of therapeutic monoclonal antibodies (mAbs) in serum and plasma since this is a very promising and rapidly expanding group of biopharmaceuticals. Additionally, the review aims to predict the impact of strategies moving away from traditional protein cleavage isotope dilution mass spectrometry (PC-IDMS) toward approaches that are more dedicated to bioanalysis.

[1]  Juncong Yang,et al.  MRM‐based multiplexed quantitation of 67 putative cardiovascular disease biomarkers in human plasma , 2012, Proteomics.

[2]  M. Sweetser,et al.  Results of a randomized open-label crossover study of the bioequivalence of subcutaneous versus intramuscular administration of alefacept. , 2006, Dermatology online journal.

[3]  Brendan MacLean,et al.  Bioinformatics Applications Note Gene Expression Skyline: an Open Source Document Editor for Creating and Analyzing Targeted Proteomics Experiments , 2022 .

[4]  Yun Chen,et al.  Quantification of human serum transferrin using liquid chromatography-tandem mass spectrometry based targeted proteomics. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[5]  Jim X. Shen,et al.  Minimization of ion suppression in LC-MS/MS analysis through the application of strong cation exchange solid-phase extraction (SCX-SPE). , 2005, Journal of pharmaceutical and biomedical analysis.

[6]  Robert J Beynon,et al.  QconCATs: design and expression of concatenated protein standards for multiplexed protein quantification , 2012, Analytical and Bioanalytical Chemistry.

[7]  Darryl B. Hardie,et al.  A quantitative study of the effects of chaotropic agents, surfactants, and solvents on the digestion efficiency of human plasma proteins by trypsin. , 2010, Journal of proteome research.

[8]  Richard D. Smith,et al.  Charge competition and the linear dynamic range of detection in electrospray ionization mass spectrometry , 2004, Journal of the American Society for Mass Spectrometry.

[9]  D. Padhi,et al.  An Extended Terminal Half-Life for Darbepoetin Alfa , 2006, Clinical pharmacokinetics.

[10]  Yehia M. Ibrahim,et al.  Pulsed multiple reaction monitoring approach to enhancing sensitivity of a tandem quadrupole mass spectrometer. , 2011, Analytical chemistry.

[11]  C. Lenz,et al.  Multiple reaction monitoring cubed for protein quantification at the low nanogram/milliliter level in nondepleted human serum. , 2009, Analytical chemistry.

[12]  G. Becker Stable isotopic labeling of proteins for quantitative proteomic applications. , 2008, Briefings in functional genomics & proteomics.

[13]  Giuseppe Caruso,et al.  Immunoprecipitation on magnetic beads and liquid chromatography-tandem mass spectrometry for carbonic anhydrase II quantification in human serum. , 2010, Analytical biochemistry.

[14]  Joseph P Balthasar,et al.  Nano-scale liquid chromatography/mass spectrometry and on-the-fly orthogonal array optimization for quantification of therapeutic monoclonal antibodies and the application in preclinical analysis. , 2012, Journal of chromatography. A.

[15]  George G Klee,et al.  Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-Ms/MS using protein cleavage and isotope dilution mass spectrometry. , 2004, Journal of proteome research.

[16]  Ronald J. Moore,et al.  Enhanced Sensitivity for Selected Reaction Monitoring Mass Spectrometry-based Targeted Proteomics Using a Dual Stage Electrodynamic Ion Funnel Interface* , 2010, Molecular & Cellular Proteomics.

[17]  Darryl B. Hardie,et al.  SISCAPA Peptide Enrichment on Magnetic Beads Using an In-line Bead Trap Device*S , 2009, Molecular & Cellular Proteomics.

[18]  Jean-Philippe Charrier,et al.  The current status of clinical proteomics and the use of MRM and MRM3 for biomarker validation , 2012, Expert review of molecular diagnostics.

[19]  J. Pérez-Ruixo,et al.  Population Pharmacokinetics Meta-Analysis of Recombinant Human Erythropoietin in Healthy Subjects , 2007, Clinical pharmacokinetics.

[20]  T. Wan,et al.  Doping control analysis of recombinant human erythropoietin, darbepoetin alfa and methoxy polyethylene glycol-epoetin beta in equine plasma by nano-liquid chromatography–tandem mass spectrometry , 2010, Analytical and bioanalytical chemistry.

[21]  Heather Myler,et al.  Bioanalytical Approaches to Quantify “Total” and “Free” Therapeutic Antibodies and Their Targets: Technical Challenges and PK/PD Applications Over the Course of Drug Development , 2011, The AAPS Journal.

[22]  Eric M Gage,et al.  A strategy of plasma protein quantitation by selective reaction monitoring of an intact protein. , 2003, Analytical chemistry.

[23]  Albert J R Heck,et al.  Recent advances in peptide separation by multidimensional liquid chromatography for proteome analysis. , 2012, Journal of proteomics.

[24]  B. V. Bysted,et al.  Pegylated long-acting human growth hormone is well-tolerated in healthy subjects and possesses a potential once-weekly pharmacokinetic and pharmacodynamic treatment profile. , 2010, The Journal of clinical endocrinology and metabolism.

[25]  Ryan T Kelly,et al.  The ion funnel: theory, implementations, and applications. , 2009, Mass spectrometry reviews.

[26]  Rainer Bischoff,et al.  Internal standards in the quantitative determination of protein biopharmaceuticals using liquid chromatography coupled to mass spectrometry. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[27]  Fumin Li,et al.  Absolute quantitation of protein therapeutics in biological matrices by enzymatic digestion and LC-MS. , 2011, Bioanalysis.

[28]  Janice M. Reichert,et al.  Marketed therapeutic antibodies compendium , 2012, mAbs.

[29]  M. Miller,et al.  A mass spectrometric method for quantitation of intact insulin in blood samples. , 2001, Journal of analytical toxicology.

[30]  P. Lescuyer,et al.  Electron Transfer Dissociation Mass Spectrometry of Hemoglobin on Clinical Samples , 2012, Journal of The American Society for Mass Spectrometry.

[31]  Hongcheng Liu,et al.  Quantitation of a recombinant monoclonal antibody in monkey serum by liquid chromatography-mass spectrometry. , 2011, Analytical biochemistry.

[32]  M. Berna,et al.  Increased throughput for low-abundance protein biomarker verification by liquid chromatography/tandem mass spectrometry. , 2009, Analytical chemistry.

[33]  B. Frederick,et al.  Pharmacokinetics, pharmacodynamics and safety of a human anti-IL-6 monoclonal antibody (sirukumab) in healthy subjects in a first-in-human study. , 2011, British journal of clinical pharmacology.

[34]  J. Lee,et al.  Bioanalytical method development and validation for a large peptide HIV fusion inhibitor (Enfuvirtide, T-20) and its metabolite in human plasma using LC-MS/MS. , 2005, Journal of pharmaceutical and biomedical analysis.

[35]  Hojoong Kim,et al.  Large-scale isotype-specific quantification of Serum amyloid A 1/2 by multiple reaction monitoring in crude sera. , 2012, Journal of proteomics.

[36]  Neil L. Kelleher,et al.  Analysis of Intact Monoclonal Antibody IgG1 by Electron Transfer Dissociation Orbitrap FTMS* , 2012, Molecular & Cellular Proteomics.

[37]  Zheng Ouyang,et al.  Pellet digestion: a simple and efficient sample preparation technique for LC-MS/MS quantification of large therapeutic proteins in plasma. , 2012, Bioanalysis.

[38]  Werner Zolg,et al.  Quantification of C‐reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C‐labeled peptide standards , 2004, Proteomics.

[39]  Ke K. Zhang,et al.  Clinical Utility of Insulin-Like Growth Factor 1 and 2; Determination by High Resolution Mass Spectrometry , 2012, PloS one.

[40]  H. Karnes,et al.  Investigation of endogenous blood plasma phospholipids, cholesterol and glycerides that contribute to matrix effects in bioanalysis by liquid chromatography/mass spectrometry. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[41]  D. Muddiman,et al.  Absolute quantification of C-reactive protein in human plasma derived from patients with epithelial ovarian cancer utilizing protein cleavage isotope dilution mass spectrometry. , 2009, Journal of proteome research.

[42]  H. Rodriguez,et al.  Mass spectrometry‐based targeted quantitative proteomics: Achieving sensitive and reproducible detection of proteins , 2012, Proteomics.

[43]  Christophe Bruley,et al.  Development of a Protein Standard Absolute Quantification (PSAQ™) assay for the quantification of Staphylococcus aureus enterotoxin A in serum. , 2012, Journal of proteomics.

[44]  B. Güttler,et al.  Protein quantification by isotope dilution mass spectrometry of proteolytic fragments: cleavage rate and accuracy. , 2008, Analytical chemistry.

[45]  Richard G Kay,et al.  The application of ultra-performance liquid chromatography/tandem mass spectrometry to the detection and quantitation of apolipoproteins in human serum. , 2007, Rapid communications in mass spectrometry : RCM.

[46]  Y. Li,et al.  Quantification of endostar in rat plasma by LC-MS/MS and its application in a pharmacokinetic study. , 2012, Journal of pharmaceutical and biomedical analysis.

[47]  J. Mesirov,et al.  Prediction of high-responding peptides for targeted protein assays by mass spectrometry , 2009, Nature Biotechnology.

[48]  J. Koomen,et al.  Evaluation of protein quantification using standard peptides containing single conservative amino acid replacements. , 2012, Journal of mass spectrometry : JMS.

[49]  Kendall W. Cradic,et al.  Quantification of serum 1-84 parathyroid hormone in patients with hyperparathyroidism by immunocapture in situ digestion liquid chromatography-tandem mass spectrometry. , 2010, Clinical chemistry.

[50]  J. Hale,et al.  Strategic use of immunoprecipitation and LC/MS/MS for trace-level protein quantification: myosin light chain 1, a biomarker of cardiac necrosis. , 2007, Analytical chemistry.

[51]  Susan E Abbatiello,et al.  Evaluation of Large Scale Quantitative Proteomic Assay Development Using Peptide Affinity-based Mass Spectrometry* , 2011, Molecular & Cellular Proteomics.

[52]  Fumin Li,et al.  Accelerated tryptic digestion of proteins in plasma for absolute quantitation using a protein internal standard by liquid chromatography/tandem mass spectrometry. , 2009, Rapid communications in mass spectrometry : RCM.

[53]  Olivier Heudi,et al.  Towards absolute quantification of therapeutic monoclonal antibody in serum by LC-MS/MS using isotope-labeled antibody standard and protein cleavage isotope dilution mass spectrometry. , 2008, Analytical chemistry.

[54]  T. Shaler,et al.  Quantification of intermediate-abundance proteins in serum by multiple reaction monitoring mass spectrometry in a single-quadrupole ion trap. , 2006, Analytical chemistry.

[55]  Liang-Yu Shih,et al.  An improved trypsin digestion method minimizes digestion-induced modifications on proteins. , 2009, Analytical biochemistry.

[56]  Hendrik Neubert,et al.  Sequential protein and peptide immunoaffinity capture for mass spectrometry-based quantification of total human β-nerve growth factor. , 2013, Analytical chemistry.

[57]  G. Nicol,et al.  Use of an Immunoaffinity-Mass Spectrometry-based Approach for the Quantification of Protein Biomarkers from Serum Samples of Lung Cancer Patients* , 2008, Molecular & Cellular Proteomics.

[58]  Total on-line analysis of a target protein from plasma by immunoextraction, digestion and liquid chromatography-mass spectrometry. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[59]  Xu Shi,et al.  Quantification of Cardiovascular Biomarkers in Patient Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution* , 2009, Molecular & Cellular Proteomics.

[60]  Hendrik Neubert,et al.  Clinical pharmacokinetic assessment of an anti-MAdCAM monoclonal antibody therapeutic by LC-MS/MS. , 2012, Analytical chemistry.

[61]  J. Schellens,et al.  Enzymatic digestion as a tool for the LC-MS/MS quantification of large peptides in biological matrices: measurement of chymotryptic fragments from the HIV-1 fusion inhibitor enfuvirtide and its metabolite M-20 in human plasma. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[62]  J. Schellens,et al.  Development and validation of a quantitative assay for the measurement of two HIV-fusion inhibitors, enfuvirtide and tifuvirtide, and one metabolite of enfuvirtide (M-20) in human plasma by liquid chromatography-tandem mass spectrometry. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[63]  E. Ezan,et al.  Immunopurification and mass spectrometric quantification of the active form of a chimeric therapeutic antibody in human serum. , 2008, Analytical chemistry.

[64]  M. Quaglia,et al.  Considering the advantages and pitfalls of the use of isotopically labeled protein standards for accurate protein quantification. , 2011, Bioanalysis.

[65]  Xinping Fang,et al.  LC-MS/MS approach for quantification of therapeutic proteins in plasma using a protein internal standard and 2D-solid-phase extraction cleanup. , 2007, Analytical chemistry.

[66]  Ang Liu,et al.  Investigation of an on-line two-dimensional chromatographic approach for peptide analysis in plasma by LC-MS-MS. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[67]  M. Mann,et al.  Stable Isotope Labeling by Amino Acids in Cell Culture, SILAC, as a Simple and Accurate Approach to Expression Proteomics* , 2002, Molecular & Cellular Proteomics.

[68]  Long Yuan,et al.  Simple and efficient digestion of a monoclonal antibody in serum using pellet digestion: comparison with traditional digestion methods in LC-MS/MS bioanalysis. , 2012, Bioanalysis.

[69]  Philip Brownridge,et al.  The importance of the digest: proteolysis and absolute quantification in proteomics. , 2011, Methods.

[70]  U. Bondesson,et al.  A new analytical method based on anti-EPO monolith column and LC-FAIMS-MS/MS for the detection of rHuEPOs in horse plasma and urine samples. , 2012, The Analyst.

[71]  Joseph P Balthasar,et al.  High-throughput method development for sensitive, accurate, and reproducible quantification of therapeutic monoclonal antibodies in tissues using orthogonal array optimization and nano liquid chromatography/selected reaction monitoring mass spectrometry. , 2012, Analytical chemistry.

[72]  Darryl B. Hardie,et al.  Mass spectrometric quantitation of peptides and proteins using Stable Isotope Standards and Capture by Anti-Peptide Antibodies (SISCAPA). , 2004, Journal of proteome research.

[73]  Daniel B. Martin,et al.  Computational prediction of proteotypic peptides for quantitative proteomics , 2007, Nature Biotechnology.

[74]  L L Needham,et al.  Isotope dilution--mass spectrometric quantification of specific proteins: model application with apolipoprotein A-I. , 1996, Clinical chemistry.

[75]  Andrew C. Chan,et al.  Therapeutic antibodies for autoimmunity and inflammation , 2010, Nature Reviews Immunology.

[76]  T. Olah,et al.  Quantitation of therapeutic proteins following direct trypsin digestion of dried blood spot samples and detection by LC-MS-based bioanalytical methods in drug discovery. , 2012, Bioanalysis.

[77]  Z. Ouyang,et al.  A strategy for liquid chromatography/tandem mass spectrometry based quantitation of pegylated protein drugs in plasma using plasma protein precipitation with water-miscible organic solvents and subsequent trypsin digestion to generate surrogate peptides for detection. , 2011, Rapid communications in mass spectrometry : RCM.

[78]  K. Rose,et al.  Development of an Isotope Dilution Assay for Precise Determination of Insulin, C-peptide, and Proinsulin Levels in Non-diabetic and Type II Diabetic Individuals with Comparison to Immunoassay* , 1997, The Journal of Biological Chemistry.

[79]  Jennifer A Mead,et al.  MRMaid, the Web-based Tool for Designing Multiple Reaction Monitoring (MRM) Transitions* , 2009, Molecular & Cellular Proteomics.

[80]  L. Bowers,et al.  Immunoaffinity trapping of urinary human chorionic gonadotropin and its high-performance liquid chromatographic-mass spectrometric confirmation. , 1996, Journal of chromatography. B, Biomedical applications.

[81]  Yuan-qing Xia,et al.  LC-FAIMS-MS/MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components. , 2008, Analytical chemistry.

[82]  David E. Golan,et al.  Protein therapeutics: a summary and pharmacological classification , 2008, Nature Reviews Drug Discovery.

[83]  F. Beaudry,et al.  Internal standard strategies for relative and absolute quantitation of peptides in biological matrices by liquid chromatography tandem mass spectrometry. , 2012, Biomedical chromatography : BMC.

[84]  D R Mani,et al.  Developing multiplexed assays for troponin I and interleukin-33 in plasma by peptide immunoaffinity enrichment and targeted mass spectrometry. , 2009, Clinical chemistry.

[85]  E. Paus,et al.  Absolute ProGRP quantification in a clinical relevant concentration range using LC-MS/MS and a comprehensive internal standard. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[86]  S. Carr,et al.  Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution*S , 2007, Molecular & Cellular Proteomics.

[87]  B. Frederick,et al.  Golimumab pharmacokinetics after repeated subcutaneous and intravenous administrations in patients with rheumatoid arthritis and the effect of concomitant methotrexate: an open-label, randomized study. , 2012, Clinical therapeutics.

[88]  Jennifer N. Sutton,et al.  Rapid development of sensitive, high-throughput, quantitative and highly selective mass spectrometric targeted immunoassays for clinically important proteins in human plasma and serum. , 2013, Clinical biochemistry.

[89]  Christophe Bruley,et al.  PSAQ™ standards for accurate MS-based quantification of proteins: from the concept to biomedical applications. , 2012, Journal of mass spectrometry : JMS.

[90]  J. Reichert Which are the antibodies to watch in 2012? , 2012, mAbs.

[91]  Susan E Abbatiello,et al.  Effect of collision energy optimization on the measurement of peptides by selected reaction monitoring (SRM) mass spectrometry. , 2010, Analytical chemistry.

[92]  J. Reichert,et al.  Development trends for human monoclonal antibody therapeutics , 2010, Nature Reviews Drug Discovery.

[93]  E. Diamandis,et al.  The bottleneck in the cancer biomarker pipeline and protein quantification through mass spectrometry-based approaches: current strategies for candidate verification. , 2010, Clinical chemistry.

[94]  M. Bidlingmaier,et al.  Quantification of growth hormone in serum by isotope dilution mass spectrometry. , 2010, Analytical biochemistry.

[95]  T. G. Halvorsen,et al.  Digging deeper into the field of the small cell lung cancer tumor marker ProGRP: a method for differentiation of its isoforms. , 2013, Journal of proteome research.

[96]  G. Hortin,et al.  The dynamic range problem in the analysis of the plasma proteome. , 2010, Journal of proteomics.

[97]  Shujia Dai,et al.  Quantification of sifuvirtide in monkey plasma by an on-line solid-phase extraction procedure combined with liquid chromatography/electrospray ionization tandem mass spectrometry. , 2005, Rapid communications in mass spectrometry : RCM.

[98]  Yuan-Qing Xia,et al.  It is time for a paradigm shift in drug discovery bioanalysis: from SRM to HRMS. , 2011, Journal of mass spectrometry : JMS.

[99]  Hendrik Neubert,et al.  Online high-flow peptide immunoaffinity enrichment and nanoflow LC-MS/MS: assay development for total salivary pepsin/pepsinogen. , 2010, Clinical chemistry.

[100]  N. Sadagopan,et al.  A universal strategy for development of a method for absolute quantification of therapeutic monoclonal antibodies in biological matrices using differential dimethyl labeling coupled with ultra performance liquid chromatography-tandem mass spectrometry. , 2009, Analytical chemistry.

[101]  F. C. Dougherty,et al.  Pharmacokinetics and pharmacodynamics of intravenous and subcutaneous continuous erythropoietin receptor activator (C.E.R.A.) in patients with chronic kidney disease. , 2006, Clinical journal of the American Society of Nephrology : CJASN.

[102]  Christophe Bruley,et al.  Accurate Quantification of Cardiovascular Biomarkers in Serum Using Protein Standard Absolute Quantification (PSAQ™) and Selected Reaction Monitoring* , 2011, Molecular & Cellular Proteomics.

[103]  Hoguen Kim,et al.  Identification of low-abundance cancer biomarker candidate TIMP1 from serum with lectin fractionation and peptide affinity enrichment by ultrahigh-resolution mass spectrometry. , 2012, Analytical chemistry.

[104]  Hendrik Neubert,et al.  An immunoaffinity liquid chromatography-tandem mass spectrometry assay for the quantitation of matrix metalloproteinase 9 in mouse serum. , 2010, Analytical biochemistry.

[105]  B. Davis,et al.  LC-MS/MS Quantification of Zn-α2 Glycoprotein: A Potential Serum Biomarker for Prostate Cancer , 2007 .

[106]  Hossein Salimi-Moosavi,et al.  General LC-MS/MS method approach to quantify therapeutic monoclonal antibodies using a common whole antibody internal standard with application to preclinical studies. , 2012, Analytical chemistry.

[107]  William S. Hancock,et al.  Development of different analysis platforms with LC-MS for pharmacokinetic studies of protein drugs. , 2009, Analytical chemistry.

[108]  Richard D. Smith,et al.  Advancing the sensitivity of selected reaction monitoring‐based targeted quantitative proteomics , 2012, Proteomics.

[109]  Robert S Plumb,et al.  Comparison of the quantification of a therapeutic protein using nominal and accurate mass MS/MS. , 2012, Bioanalysis.

[110]  K. Heinig,et al.  An improved LC-MS/MS method for the determination of taspoglutide in plasma and urine using orthogonal HILIC-RP column switching, ultra-performance LC separation and 'wrong-way-round' electrospray ionization. , 2011, Biomedical chromatography : BMC.

[111]  P. Solter,et al.  Quantification of NTproBNP in rat serum using immunoprecipitation and LC/MS/MS: a biomarker of drug-induced cardiac hypertrophy. , 2008, Analytical chemistry.

[112]  Lee Goodwin,et al.  Bioanalytical approaches to analyzing peptides and proteins by LC--MS/MS. , 2011, Bioanalysis.

[113]  Amanda G. Paulovich,et al.  An Automated and Multiplexed Method for High Throughput Peptide Immunoaffinity Enrichment and Multiple Reaction Monitoring Mass Spectrometry-based Quantification of Protein Biomarkers* , 2009, Molecular & Cellular Proteomics.

[114]  M. Mann,et al.  Mass Spectrometry-based Proteomics Using Q Exactive, a High-performance Benchtop Quadrupole Orbitrap Mass Spectrometer* , 2011, Molecular & Cellular Proteomics.

[115]  Prabha Dwivedi,et al.  Ion mobility-mass spectrometry. , 2008, Journal of mass spectrometry : JMS.

[116]  Henry H. N. Lam,et al.  PeptideAtlas: a resource for target selection for emerging targeted proteomics workflows , 2008, EMBO reports.

[117]  J. Garin,et al.  Isotope dilution strategies for absolute quantitative proteomics. , 2009, Journal of proteomics.

[118]  Mathieu Dubois,et al.  Bioanalysis of recombinant proteins and antibodies by mass spectrometry. , 2009, The Analyst.

[119]  K. Sandra,et al.  Highly efficient peptide separations in proteomics. Part 2: bi- and multidimensional liquid-based separation techniques. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[120]  E. Birks,et al.  LC−MS/MS Method for Confirmation of Recombinant Human Erythropoietin and Darbepoetin α in Equine Plasma , 2007 .

[121]  Andrew N Hoofnagle,et al.  Replacing immunoassays with tryptic digestion-peptide immunoaffinity enrichment and LC-MS/MS. , 2012, Bioanalysis.

[122]  F. Tse,et al.  A sensitive and high-throughput LC-MS/MS method for the quantification of pegylated-interferon-alpha2a in human serum using monolithic C18 solid phase extraction for enrichment. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[123]  T. Olsson,et al.  MRM assay for quantitation of complement components in human blood plasma - a feasibility study on multiple sclerosis. , 2011, Journal of proteomics.

[124]  E. Ezan,et al.  Immuno-mass spectrometry assay of EPI-HNE4, a recombinant protein inhibitor of human elastase. , 2007, Rapid communications in mass spectrometry : RCM.

[125]  Erin E. Chambers,et al.  Development of a fast method for direct analysis of intact synthetic insulins in human plasma: the large peptide challenge. , 2013, Bioanalysis.

[126]  H. Gram,et al.  Pharmacokinetic and Pharmacodynamic Properties of Canakinumab, a Human Anti-Interleukin-1β Monoclonal Antibody , 2012, Clinical Pharmacokinetics.

[127]  Thomas P Conrads,et al.  Multidimensional separation of peptides for effective proteomic analysis. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[128]  A. Salvador,et al.  Clinical Quantitation of Prostate-specific Antigen Biomarker in the Low Nanogram/Milliliter Range by Conventional Bore Liquid Chromatography-Tandem Mass Spectrometry (Multiple Reaction Monitoring) Coupling and Correlation with ELISA Tests , 2009, Molecular & Cellular Proteomics.

[129]  J. Frystyk,et al.  A comparison of pharmacokinetics and pharmacodynamics of insulin aspart, biphasic insulin aspart 70, biphasic insulin aspart 50, and human insulin: a randomized, quadruple crossover study. , 2012, Diabetes Technology & Therapeutics.

[130]  C. G. Edmonds,et al.  Tandem mass spectrometry of very large molecules. 2. Dissociation of multiply charged proline-containing proteins from electrospray ionization. , 1993, Analytical chemistry.

[131]  Wilhelm Schänzer,et al.  Current role of LC-MS(/MS) in doping control , 2007, Analytical and bioanalytical chemistry.

[132]  F. Vitzthum,et al.  Development of high-throughput chemical extraction techniques and quantitative HPLC-MS/MS (SRM) assays for clinically relevant plasma proteins. , 2010, Journal of proteome research.

[133]  D. Bergel Geigy Scientific Tables , 1991 .

[134]  Gérard Hopfgartner,et al.  Accelerated tryptic digestion for the analysis of biopharmaceutical monoclonal antibodies in plasma by liquid chromatography with tandem mass spectrometric detection. , 2010, Journal of chromatography. A.

[135]  Jeffrey R. Whiteaker,et al.  Sequential Multiplexed Analyte Quantification Using Peptide Immunoaffinity Enrichment Coupled to Mass Spectrometry* , 2011, Molecular & Cellular Proteomics.

[136]  P. Tebas,et al.  Enfuvirtide Does Not Require Dose Adjustment in Patients With Chronic Kidney Failure: Results of a Pharmacokinetic Study of Enfuvirtide in HIV-1-Infected Patients With Impaired Kidney Function , 2008, Journal of acquired immune deficiency syndromes.

[137]  C. Hottenstein,et al.  Absolute quantification of a therapeutic domain antibody using ultra-performance liquid chromatography-mass spectrometry and immunoassay. , 2010, Bioanalysis.

[138]  E. Ezan,et al.  Quantification of small therapeutic proteins in plasma by liquid chromatography-tandem mass spectrometry: application to an elastase inhibitor EPI-hNE4. , 2006, Analytical chemistry.

[139]  Manfred Rauh,et al.  LC-MS/MS for protein and peptide quantification in clinical chemistry. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[140]  Andrew N Hoofnagle,et al.  Simultaneous quantification of apolipoprotein A-I and apolipoprotein B by liquid-chromatography-multiple- reaction-monitoring mass spectrometry. , 2010, Clinical chemistry.

[141]  R. Aebersold,et al.  High Sensitivity Detection of Plasma Proteins by Multiple Reaction Monitoring of N-Glycosites*S , 2007, Molecular & Cellular Proteomics.

[142]  Ji Yeon Lee,et al.  Quantitative analysis of an aberrant glycoform of TIMP1 from colon cancer serum by L-PHA-enrichment and SISCAPA with MRM mass spectrometry. , 2009, Journal of proteome research.

[143]  Andrew N Hoofnagle,et al.  Quantification of thyroglobulin, a low-abundance serum protein, by immunoaffinity peptide enrichment and tandem mass spectrometry. , 2008, Clinical chemistry.

[144]  P. López-Saura,et al.  Pharmacokinetic and pharmacodynamic comparison of two "pegylated" interferon alpha-2 formulations in healthy male volunteers: a randomized, crossover, double-blind study , 2010, BMC pharmacology.

[145]  Albert J R Heck,et al.  High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies , 2012, Nature Methods.

[146]  H. T. Karnes,et al.  Quantification of Alefacept, an immunosuppressive fusion protein in human plasma using a protein analogue internal standard, trypsin cleaved signature peptides and liquid chromatography tandem mass spectrometry. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[147]  L. Zhang,et al.  Recent advances in micro-scale and nano-scale high-performance liquid-phase chromatography for proteome research , 2011, Analytical and bioanalytical chemistry.

[148]  W. V. van Dongen,et al.  LC-MS systems for quantitative bioanalysis. , 2012, Bioanalysis.

[149]  J. Campbell,et al.  Targeted ion parking for the quantitation of biotherapeutic proteins: Concepts and preliminary data , 2010, Journal of the American Society for Mass Spectrometry.

[150]  S. Hubbard,et al.  Prediction of missed proteolytic cleavages for the selection of surrogate peptides for quantitative proteomics. , 2012, Omics : a journal of integrative biology.

[151]  E. De Pauw,et al.  Development of an absolute quantification method targeting growth hormone biomarkers using liquid chromatography coupled to isotope dilution mass spectrometry. , 2007, Journal of chromatography. A.

[152]  J. Heilig,et al.  Differentiation and quantification of endogenous and recombinant-methionyl human leptin in clinical plasma samples by immunocapture/mass spectrometry. , 2012, Journal of pharmaceutical and biomedical analysis.

[153]  Balwir Matharoo-Ball,et al.  Enrichment of low molecular weight serum proteins using acetonitrile precipitation for mass spectrometry based proteomic analysis. , 2008, Rapid communications in mass spectrometry : RCM.

[154]  M. Giera,et al.  Protein digestion: an overview of the available techniques and recent developments. , 2013, Journal of proteome research.

[155]  Robertson Craig,et al.  Open source system for analyzing, validating, and storing protein identification data. , 2004, Journal of proteome research.

[156]  Robert J Beynon,et al.  Absolute Multiplexed Protein Quantification Using QconCAT Technology , 2012, Quantitative Methods in Proteomics.

[157]  G. Ball,et al.  High-throughput ultra-high-performance liquid chromatography/tandem mass spectrometry quantitation of insulin-like growth factor-I and leucine-rich alpha-2-glycoprotein in serum as biomarkers of recombinant human growth hormone administration. , 2009, Rapid communications in mass spectrometry : RCM.

[158]  M. Thevis,et al.  Quantification of human insulin-like growth factor-1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionisation tandem mass spectrometry. , 2008, Rapid communications in mass spectrometry : RCM.

[159]  R. Beynon,et al.  Multiplexed absolute quantification in proteomics using artificial QCAT proteins of concatenated signature peptides , 2005, Nature Methods.

[160]  M. Sakagami,et al.  Determination of oxyntomodulin, an anorectic polypeptide, in rat plasma using 2D-LC-MS/MS coupled with ion pair chromatography. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[161]  Michael E. Lassman,et al.  A rapid method for cross-species quantitation of apolipoproteins A1, B48 and B100 in plasma by ultra-performance liquid chromatography/tandem mass spectrometry. , 2012, Rapid communications in mass spectrometry : RCM.

[162]  L. Reubsaet,et al.  Immuno-capture as ultimate sample cleanup in LC-MS/MS determination of the early stage biomarker ProGRP. , 2009, Journal of separation science.

[163]  C. Bystrom,et al.  Narrow mass extraction of time-of-flight data for quantitative analysis of proteins: determination of insulin-like growth factor-1. , 2011, Analytical chemistry.

[164]  M. Karas,et al.  Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI? , 2003, Journal of the American Society for Mass Spectrometry.

[165]  N. Cnubben,et al.  Quantitative analysis of Tenecteplase in rat plasma samples using LC-MS/MS as an alternative for ELISA. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[166]  Darrell Ricke,et al.  Absolute quantification of monoclonal antibodies in biofluids by liquid chromatography-tandem mass spectrometry. , 2008, Analytical chemistry.

[167]  L. Nováková,et al.  A review of current trends and advances in modern bio-analytical methods: chromatography and sample preparation. , 2009, Analytica chimica acta.

[168]  K. Kito,et al.  A synthetic protein approach toward accurate mass spectrometric quantification of component stoichiometry of multiprotein complexes. , 2007, Journal of proteome research.

[169]  N. Anderson,et al.  The Human Plasma Proteome , 2002, Molecular & Cellular Proteomics.

[170]  R. Aebersold,et al.  Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions , 2012, Nature Methods.

[171]  L. Vereyken,et al.  Comparison of triple quadrupole and high-resolution TOF-MS for quantification of peptides. , 2012, Bioanalysis.

[172]  B. Domon,et al.  Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer* , 2012, Molecular & Cellular Proteomics.

[173]  Jeffrey R. Whiteaker,et al.  Peptide immunoaffinity enrichment coupled with mass spectrometry for peptide and protein quantification. , 2011, Clinics in laboratory medicine.

[174]  B. Liedert,et al.  Comparison of the pharmacokinetics, safety and tolerability of two concentrations of a new liquid recombinant human growth hormone formulation versus the freeze-dried formulation , 2010, BMC clinical pharmacology.

[175]  C. Borchers,et al.  Comparison of standard- and nano-flow liquid chromatography platforms for MRM-based quantitation of putative plasma biomarker proteins , 2012, Analytical and Bioanalytical Chemistry.

[176]  Andrew N Hoofnagle,et al.  The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry. , 2009, Journal of immunological methods.

[177]  U. Lövgren,et al.  Quantitative determination of peptide drug in human plasma samples at low pg/ml levels using coupled column liquid chromatography-tandem mass spectrometry. , 2010, Journal of pharmaceutical and biomedical analysis.

[178]  A. Hoofnagle,et al.  Measurement of thyroglobulin by liquid chromatography-tandem mass spectrometry in serum and plasma in the presence of antithyroglobulin autoantibodies. , 2013, Clinical chemistry.

[179]  Louis M Weiner,et al.  Fully Human Therapeutic Monoclonal Antibodies , 2006, Journal of immunotherapy.

[180]  L. Reubsaet,et al.  Immuno-MS based targeted proteomics: highly specific, sensitive, and reproducible human chorionic gonadotropin determination for clinical diagnostics and doping analysis. , 2012, Analytical chemistry.

[181]  Douglas A Jeffery,et al.  "Product ion monitoring" assay for prostate-specific antigen in serum using a linear ion-trap. , 2008, Journal of proteome research.

[182]  Damon May,et al.  MRMer, an Interactive Open Source and Cross-platform System for Data Extraction and Visualization of Multiple Reaction Monitoring Experiments*S⃞ , 2008, Molecular & Cellular Proteomics.

[183]  David C Muddiman,et al.  Evaluation of a cleavable stable isotope labeled synthetic peptide for absolute protein quantification using LC-MS/MS. , 2004, Journal of proteome research.

[184]  J. Pérez-Ruixo,et al.  Pharmacokinetics and Pharmacodynamics of the Erythropoietin Mimetibody™ Construct CNTO 528 in Healthy Subjects , 2009, Clinical Pharmacokinetics.

[185]  F. Vandenesch,et al.  Isotope-labeled Protein Standards , 2007, Molecular & Cellular Proteomics.

[186]  T. Klaassen,et al.  Validated quantitation method for a peptide in rat serum using liquid chromatography/high-field asymmetric waveform ion mobility spectrometry. , 2009, Rapid communications in mass spectrometry : RCM.