Real-Time and Interactive MRI

Free of ionizing radiation, unlike x-ray, CT, and PET, MRI is recognized as an ideal tool to monitor and control interventions. Its advantages include a superior spatial resolution and soft tissue contrast to help delineate tissue abnormality and the ability to provide cross-sectional images in any orientation. It is also able to noninvasively monitor temperature changes, making it ideal for monitoring energy deposition during thermal ablation. To leverage these advantages in various types of interventions, a number of groups have made and continue to make efforts to exploit MRI in the operating room. Interventional MRI differs from diagnostic MRI in its interactive and real-time nature whereby the progress of intervention is instantly visualized by the physician as feedback. To this end, imaging parameters may often require adjustment so that position and orientation of the imaging plane track the locations of needles and catheters or movement of a focal lesion during a procedure. Since there are trade-offs to be made in image contrast, signal-to-noise ratio, spatial resolution, and temporal resolution when choosing MRI techniques, they must be carefully selected depending on their purpose. In this chapter, we review a wide range of imaging techniques that enable interactive and real-time MRI for interventional guidance.

[1]  Jürgen Hennig,et al.  Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part II: Echoes in imaging sequences , 1991 .

[2]  Richard Kijowski,et al.  Consistent non‐cartesian off‐axis MRI quality: Calibrating and removing multiple sources of demodulation phase errors , 2007, Magnetic resonance in medicine.

[3]  Jeffrey L Duerk,et al.  The catheter-driven MRI scanner: a new approach to intravascular catheter tracking and imaging-parameter adjustment for interventional MRI. , 2004, AJR. American journal of roentgenology.

[4]  Jeffrey L Duerk,et al.  Pulse sequences and system interfaces for interventional and real‐time MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[5]  G. Hansson,et al.  Passive catheter tracking during interventional MRI using hyperpolarized 13C , 2007, Magnetic resonance in medicine.

[6]  Debiao Li,et al.  Use of internal coils for independent and direct MR imaging-guided endovascular device tracking. , 2003, Journal of vascular and interventional radiology : JVIR.

[7]  Bruno Madore,et al.  Reduced field‐of‐view MRI with two‐dimensional spatially‐selective RF excitation and UNFOLD , 2005, Magnetic resonance in medicine.

[8]  John M Pauly,et al.  Triggered, navigated, multi‐baseline method for proton resonance frequency temperature mapping with respiratory motion , 2003, Magnetic resonance in medicine.

[9]  David Atkinson,et al.  Real-Time Reconstruction of Sensitivity Encoded Radial Magnetic Resonance Imaging Using a Graphics Processing Unit , 2009, IEEE Transactions on Medical Imaging.

[10]  Klaus Scheffler,et al.  Fast frequency mapping with balanced SSFP: Theory and application to proton‐resonance frequency shift thermometry , 2004, Magnetic resonance in medicine.

[11]  N J Pelc,et al.  Unaliasing by Fourier‐encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI , 1999, Magnetic resonance in medicine.

[12]  R Lufkin,et al.  Phase imaging on a .2‐T MR scanner: Application to temperature monitoring during ablation procedures , 1997, Journal of magnetic resonance imaging : JMRI.

[13]  Dana C Peters,et al.  Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view , 2004, Magnetic resonance in medicine.

[14]  Tzu-Chao Chuang,et al.  PROPELLER EPI: An MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions , 2005, Magnetic resonance in medicine.

[15]  R. Edelman,et al.  Resolution enhancement in single‐shot imaging using simultaneous acquisition of spatial harmonics (SMASH) , 1999, Magnetic resonance in medicine.

[16]  C. Moonen,et al.  Real‐time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney , 2011, NMR in biomedicine.

[17]  J. Lewin,et al.  MRI-guided injection procedures of the temporomandibular joints in children and adults: technique, accuracy, and safety. , 2009, AJR. American journal of roentgenology.

[18]  Jonathan S. Lewin,et al.  Dynamic tracking in interventional MRI using wavelet-encoded gradient-echo sequences , 1998, IEEE Transactions on Medical Imaging.

[19]  D. Firmin,et al.  Phase ordering with automatic window selection (PAWS): A novel motion‐resistant technique for 3D coronary imaging , 2000, Magnetic resonance in medicine.

[20]  G. Maclair,et al.  Online correction of respiratory‐induced field disturbances for continuous MR‐thermometry in the breast , 2009, Magnetic resonance in medicine.

[21]  Donald W. Kormos,et al.  Glioma Resection in a Shared-resource Magnetic Resonance Operating Room after Optimal Image-guided Frameless Stereotactic Resection , 2001, Neurosurgery.

[22]  S. Schoenberg,et al.  High‐resolution MR‐imaging of the liver with T2‐weighted sequences using integrated parallel imaging: Comparison of prospective motion correction and respiratory triggering , 2004, Journal of magnetic resonance imaging : JMRI.

[23]  J N Lee,et al.  MR fluoroscopy: Technical feasibility , 1988, Magnetic resonance in medicine.

[24]  M. L. Lauzon,et al.  A simulation‐based analysis of the potential of compressed sensing for accelerating passive mr catheter visualization in endovascular therapy , 2010, Magnetic resonance in medicine.

[25]  Mark E Ladd,et al.  MR‐guided core biopsy with MR fluoroscopy using a short, wide‐bore 1.5‐Tesla scanner: Feasibility and initial results , 2008, Journal of magnetic resonance imaging : JMRI.

[26]  G. Casola,et al.  A wire-sheath system for MR-guided biopsy and drainage: laboratory studies and experience in 10 patients. , 1988, AJR. American journal of roentgenology.

[27]  H. Hricak,et al.  Magnetic resonance imaging with respiratory gating: techniques and advantages. , 1984, AJR. American journal of roentgenology.

[28]  M. Ladd,et al.  Reduction of resonant RF heating in intravascular catheters using coaxial chokes , 2000, Magnetic Resonance in Medicine.

[29]  E. McVeigh,et al.  Interventional cardiovascular procedures guided by real‐time MR imaging: An interactive interface using multiple slices, adaptive projection modes and live 3D renderings , 2007, Journal of magnetic resonance imaging : JMRI.

[30]  J. Felmlee,et al.  Orbital navigator echoes for motion measurements in magnetic resonance imaging , 1995, Magnetic resonance in medicine.

[31]  Dana C Peters,et al.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter‐only views , 2003, Magnetic resonance in medicine.

[32]  Kaori Togashi,et al.  MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. , 2008, AJR. American journal of roentgenology.

[33]  E P Wilkinson,et al.  Comparative tracking error analysis of five different optical tracking systems. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[34]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[35]  K. Arfanakis,et al.  k‐space undersampling in PROPELLER imaging , 2005, Magnetic resonance in medicine.

[36]  J Szumowski,et al.  SIMA: Simultaneous Multislice Acquisition of MR Images by Hadamard‐Encoded Excitation , 1988, Journal of computer assisted tomography.

[37]  L P Panych,et al.  A dynamically adaptive imaging algorithm for wavelet‐encoded MRI , 1994, Magnetic resonance in medicine.

[38]  Jing Yuan,et al.  Multipathway sequences for MR thermometry , 2011, Magnetic resonance in medicine.

[39]  MR monitoring of NaCl-enhanced radiofrequency ablations: observations on low- and high-field-strength MR images with pathologic correlation. , 2010, Radiology.

[40]  Max A Viergever,et al.  Passive tracking exploiting local signal conservation: The white marker phenomenon , 2003, Magnetic resonance in medicine.

[41]  T Vaara,et al.  Nerve root infiltration of the first sacral root with MRI guidance , 2000, Journal of magnetic resonance imaging : JMRI.

[42]  Jeffrey Tsao,et al.  Ultrafast imaging: Principles, pitfalls, solutions, and applications , 2010, Journal of magnetic resonance imaging : JMRI.

[43]  R C Grimm,et al.  Real‐time interactive magnetic resonance imaging , 1990, Magnetic resonance in medicine.

[44]  J S Lewin,et al.  Fast T2‐weighted imaging by PSIF at 0.2 T for interventional MRI , 1999, Magnetic resonance in medicine.

[45]  D. Feinberg,et al.  Halving MR imaging time by conjugation: demonstration at 3.5 kG. , 1986, Radiology.

[46]  Cengizhan Ozturk,et al.  Interventional MRI using multiple 3D angiography roadmaps with real‐time imaging , 2010, Journal of magnetic resonance imaging : JMRI.

[47]  H Saint-Jalmes,et al.  MR temperature measurement in liver tissue at 0.23 T with a steady‐state free precession sequence , 2002, Magnetic resonance in medicine.

[48]  P G Morris,et al.  Human whole body imaging and detection of breast tumours by n.m.r. , 1980, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[49]  J S Lewin,et al.  An optical system for wireless detuning of parallel resonant circuits. , 2000, Journal of magnetic resonance imaging : JMRI.

[50]  P Boesiger,et al.  Guidewire antennas for MR fluoroscopy , 1997, Magnetic resonance in medicine.

[51]  D. Kacher,et al.  Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP) , 2000, Magnetic resonance in medicine.

[52]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[53]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[54]  Bruno Quesson,et al.  Real‐time geometric distortion correction for interventional imaging with echo‐planar imaging (EPI) , 2009, Magnetic resonance in medicine.

[55]  J. McClelland,et al.  MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning , 2006, Physics in medicine and biology.

[56]  J F Debatin,et al.  Active biplanar MR tracking for biopsies in humans. , 1997, AJR. American journal of roentgenology.

[57]  R R Edelman,et al.  MR-guided aspiration biopsy: needle design and clinical trials. , 1986, Radiology.

[58]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[59]  R. Maciunas,et al.  Intraoperative MRI with a rotating, tiltable surgical table: a time use study and clinical results in 122 patients. , 2007, AJR. American journal of roentgenology.

[60]  R F Busse,et al.  Interactive fast spin‐echo imaging , 2000, Magnetic resonance in medicine.

[61]  Sébastien Roujol,et al.  Online real‐time reconstruction of adaptive TSENSE with commodity CPU/GPU hardware , 2009, Magnetic resonance in medicine.

[62]  Peter Boesiger,et al.  k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations , 2003, Magnetic resonance in medicine.

[63]  Peter Boesiger,et al.  Compressed sensing in dynamic MRI , 2008, Magnetic resonance in medicine.

[64]  V Rasche,et al.  Catheter tracking using continuous radial MRI , 1997, Magnetic resonance in medicine.

[65]  Ergin Atalar,et al.  SSFP‐based MR thermometry , 2004, Magnetic resonance in medicine.

[66]  M. Bock,et al.  Automatic passive tracking of an endorectal prostate biopsy device using phase‐only cross‐correlation , 2008, Magnetic resonance in medicine.

[67]  Klaus Radermacher,et al.  Assessment of optical localizer accuracy for computer aided surgery systems , 2010, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[68]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[69]  J. Carr,et al.  Passive catheter tracking using MRI: Comparison of conventional and magnetization‐prepared FLASH , 2002, Journal of magnetic resonance imaging : JMRI.

[70]  A. Haase,et al.  Rapid NMR Imaging Using Low Flip-Angle Pulses , 2004 .

[71]  Volker Rasche,et al.  Continuous radial data acquisition for dynamic MRI , 1995, Magnetic resonance in medicine.

[72]  Juan M. Santos,et al.  Real‐time MR thermometry for monitoring HIFU ablations of the liver , 2010, Magnetic resonance in medicine.

[73]  Sébastien Roujol,et al.  Real‐time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues , 2010, Magnetic resonance in medicine.

[74]  V Rasche,et al.  Motion compensated projection reconstruction , 1999, Magnetic resonance in medicine.

[75]  L P Panych,et al.  Implementation of wavelet‐encoded MR imaging , 1993, Journal of magnetic resonance imaging : JMRI.

[76]  J Velikina,et al.  Highly constrained backprojection for time‐resolved MRI , 2006, Magnetic resonance in medicine.

[77]  S Chandra,et al.  Application of reduced‐encoding imaging with generalized‐series reconstruction (RIGR) in dynamic MR imaging , 1996, Journal of magnetic resonance imaging : JMRI.

[78]  G. Schumacher,et al.  Imaging sequences for intraoperative MR-guided laparoscopic liver resection in 1.0-T high field open MRI , 2009, European Radiology.

[79]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.

[80]  Shigehiro Morikawa,et al.  Feasibility of Respiratory Triggering for MR-Guided Microwave Ablation of Liver Tumors Under General Anesthesia , 2004, CardioVascular and Interventional Radiology.

[81]  M Bock,et al.  A Faraday effect position sensor for interventional magnetic resonance imaging , 2006, Physics in medicine and biology.

[82]  Jeffrey L Duerk,et al.  Comparison of MR imaging sequences for liver and head and neck interventions: is there a single optimal sequence for all purposes? , 2004, Academic radiology.

[83]  P Börnert,et al.  Interactive reduced FOV imaging for projection reconstruction and spiral acquisition. , 2001, Magnetic resonance imaging.

[84]  M Wendt,et al.  A multielement RF coil for MRI guidance of interventional devices , 2001, Journal of magnetic resonance imaging : JMRI.

[85]  R. Kikinis,et al.  Superconducting open-configuration MR imaging system for image-guided therapy. , 1995, Radiology.

[86]  C J Hardy,et al.  Real‐time acquisition, display, and interactive graphic control of NMR cardiac profiles and images , 1993, Magnetic resonance in medicine.

[87]  David Atkinson,et al.  Cartesian SENSE and k‐t SENSE reconstruction using commodity graphics hardware , 2008, Magnetic resonance in medicine.

[88]  Ozgur Kocaturk,et al.  Visualization of active devices and automatic slice repositioning (“SnapTo”) for MRI‐guided interventions , 2010, Magnetic resonance in medicine.

[89]  F Viñuela,et al.  Head and neck lesions: MR-guided aspiration biopsy. , 1989, Radiology.

[90]  Jens Frahm,et al.  Two‐dimensional spatially‐selective RF excitation pulses in echo‐planar imaging , 2002, Magnetic resonance in medicine.

[91]  Ken Masamune,et al.  Adaptive 4D MR imaging using navigator‐based respiratory signal for MRI‐guided therapy , 2008, Magnetic resonance in medicine.

[92]  J A de Zwart,et al.  On‐line correction and visualization of motion during MRI‐controlled hyperthermia , 2001, Magnetic resonance in medicine.

[93]  L Kaufman,et al.  Inner volume MR imaging: technical concepts and their application. , 1985, Radiology.

[94]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[95]  Feng Huang,et al.  k‐t GRAPPA: A k‐space implementation for dynamic MRI with high reduction factor , 2005, Magnetic resonance in medicine.

[96]  Bob S. Hu,et al.  High‐resolution real‐time spiral MRI for guiding vascular interventions in a rabbit model at 1.5T , 2005, Journal of magnetic resonance imaging : JMRI.

[97]  K. Scheffler,et al.  Principles and applications of balanced SSFP techniques , 2003, European Radiology.

[98]  G. Mckinnon,et al.  Vascular interventions guided by ultrafast MR imaging: Evaluation of different materials , 1994, Magnetic resonance in medicine.

[99]  D. Twieg The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. , 1983, Medical physics.

[100]  Eigil Samset,et al.  Dynamic MRI Scan Plane Control for Passive Tracking of Instruments and Devices , 2007, MICCAI.

[101]  S. Riederer,et al.  Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging , 1990, Magnetic resonance in medicine.

[102]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[103]  Ron Kikinis,et al.  Rapid tip tracking with MRI by a limited projection reconstruction technique , 1998, Journal of magnetic resonance imaging : JMRI.

[104]  Robert J Lederman,et al.  Interventional cardiovascular magnetic resonance imaging. , 2007, Trends in cardiovascular medicine.

[105]  K Scheffler,et al.  Automatic slice positioning (ASP) for passive real‐time tracking of interventional devices using projection‐reconstruction imaging with echo‐dephasing (PRIDE) , 2009, Magnetic resonance in medicine.

[106]  Bruno Quesson,et al.  Real‐time monitoring of radiofrequency ablation of rabbit liver by respiratory‐gated quantitative temperature MRI , 2006, Journal of magnetic resonance imaging : JMRI.

[107]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[108]  M Bock,et al.  Targeted‐HASTE imaging with automated device tracking for MR‐guided needle interventions in closed‐bore MR systems , 2006, Magnetic resonance in medicine.

[109]  M A Viergever,et al.  Visualization of dedicated catheters using fast scanning techniques with potential for MR‐guided vascular interventions , 1996, Magnetic resonance in medicine.

[110]  J S Lewin,et al.  Invited. Remember true FISP? a high SNR, near 1‐second imaging method for T2‐like contrast in interventional MRI at .2 T , 1998, Journal of magnetic resonance imaging : JMRI.

[111]  J. Lewin,et al.  In vivo cardiovascular catheterization under real‐time MRI guidance , 2006, Journal of magnetic resonance imaging : JMRI.

[112]  Reza Razavi,et al.  Catheter tracking and visualization using 19F nuclear magnetic resonance , 2004, Magnetic resonance in medicine.

[113]  L. Panych,et al.  Reduced field‐of‐view single‐shot fast spin echo imaging using two‐dimensional spatially selective radiofrequency pulses , 2010, Journal of magnetic resonance imaging : JMRI.

[114]  D. Lomas,et al.  Interactive body magnetic resonance fluoroscopy using modified single‐shot half‐Fourier rapid acquisition with relaxation enhancement (RARE) with multiparameter control , 2002, Journal of magnetic resonance imaging : JMRI.

[115]  F. Korosec,et al.  Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. , 2000, Journal of vascular and interventional radiology : JVIR.

[116]  R Lufkin,et al.  New needle for MR-guided aspiration cytology of the head and neck. , 1987, AJR. American journal of roentgenology.

[117]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[118]  C J Bakker,et al.  Heating Around Intravascular Guidewires by Resonating RF Waves , 2000, Journal of magnetic resonance imaging : JMRI.

[119]  Bruno Madore,et al.  Using UNFOLD to remove artifacts in parallel imaging and in partial‐Fourier imaging , 2002, Magnetic resonance in medicine.

[120]  Jing Yuan,et al.  Combining two‐dimensional spatially selective RF excitation, parallel imaging, and UNFOLD for accelerated MR thermometry imaging , 2011, Magnetic resonance in medicine.

[121]  Peter Kellman,et al.  Real‐time accelerated interactive MRI with adaptive TSENSE and UNFOLD , 2003, Magnetic resonance in medicine.

[122]  E R McVeigh,et al.  Techniques for fast stereoscopic MRI , 2001, Magnetic resonance in medicine.

[123]  M. Dohi,et al.  A new image navigation system for MR-guided cryosurgery. , 2002, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[124]  Dana H Brooks,et al.  Using GRAPPA to improve autocalibrated coil sensitivity estimation for the SENSE family of parallel imaging reconstruction algorithms , 2008, Magnetic resonance in medicine.

[125]  Peter R Seevinck,et al.  Highly localized positive contrast of small paramagnetic objects using 3D center‐out radial sampling with off‐resonance reception , 2011, Magnetic resonance in medicine.

[126]  Arndt Glowinski,et al.  MR‐guided biopsy using a T2‐weighted single‐shot Zoom Imaging sequence (Local Look technique) , 1998, Journal of magnetic resonance imaging : JMRI.

[127]  J. Weaver,et al.  Wavelet‐encoded MR imaging , 1992, Magnetic resonance in medicine.

[128]  V M Runge,et al.  Respiratory gating in magnetic resonance imaging at 0.5 Tesla. , 1984, Radiology.

[129]  J S Lewin,et al.  Application of keyhole imaging to interventional MRI: A simulation study to predict sequence requirements , 1996, Journal of magnetic resonance imaging : JMRI.

[130]  W. Nitz,et al.  On the heating of linear conductive structures as guide wires and catheters in interventional MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[131]  Jörg Müller,et al.  Development of an Active Intravascular MR Device With an Optical Transmission System , 2008, IEEE Transactions on Medical Imaging.

[132]  David G Norris,et al.  Fast spin echo sequences for BOLD functional MRI , 2007, Magnetic Resonance Materials in Physics, Biology and Medicine.

[133]  P Boesiger,et al.  4D MR imaging of respiratory organ motion and its variability , 2007, Physics in medicine and biology.

[134]  S. Riederer,et al.  A spoiling sequence for suppression of residual transverse magnetization , 1990, Magnetic resonance in medicine.

[135]  F. Jolesz,et al.  Dynamically adaptive MRI with encoding by singular value decomposition , 1994, Magnetic resonance in medicine.

[136]  P. Jakob,et al.  Feasibility of Real-Time MRI With a Novel Carbon Catheter for Interventional Electrophysiology , 2009, Circulation. Arrhythmia and electrophysiology.

[137]  Bruno Quesson,et al.  Stability of real‐time MR temperature mapping in healthy and diseased human liver , 2004, Journal of magnetic resonance imaging : JMRI.

[138]  Ramin Zabih,et al.  Simultaneous multiple volume (SMV) acquisition algorithm for real-time navigator gating. , 2003, Magnetic resonance imaging.

[139]  J. J. van Vaals,et al.  “Keyhole” method for accelerating imaging of contrast agent uptake , 1993, Journal of magnetic resonance imaging : JMRI.

[140]  J. Finsterbusch Fast‐spin‐echo imaging of inner fields‐of‐view with 2D‐selective RF excitations , 2010, Journal of magnetic resonance imaging : JMRI.

[141]  L P Panych,et al.  Comparing the FAISE method with conventional dual‐echo sequences , 1991, Journal of magnetic resonance imaging : JMRI.

[143]  N L Kelekis,et al.  HASTE MR imaging: Description of technique and preliminary results in the abdomen , 1996, Journal of magnetic resonance imaging : JMRI.

[144]  Haim Azhari,et al.  Method for rapid MRI needle tracking , 2004, Magnetic resonance in medicine.

[145]  Bruno Madore,et al.  A 2D MTF approach to evaluate and guide dynamic imaging developments , 2010, Magnetic resonance in medicine.

[146]  Graham A Wright,et al.  Variable‐density adaptive imaging for high‐resolution coronary artery MRI , 2002, Magnetic resonance in medicine.

[147]  C J Hardy,et al.  Real‐time interactive MRI on a conventional scanner , 1997, Magnetic resonance in medicine.

[148]  J. Hennig Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes , 1991 .

[149]  F H Epstein,et al.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) † , 2001, Magnetic resonance in medicine.

[150]  C L Dumoulin,et al.  Intravascular MR tracking catheter: preliminary experimental evaluation. , 1995, AJR. American journal of roentgenology.

[151]  Tomoharu Shimizu,et al.  MR-guided microwave ablation for malignancies , 2007, International Journal of Clinical Oncology.

[152]  H. Berkenstadt,et al.  Novel, Compact, Intraoperative Magnetic Resonance Imaging-guided System for Conventional Neurosurgical Operating Rooms , 2001, Neurosurgery.

[153]  G H Glover,et al.  Phase‐offset multiplanar (POMP) volume imaging: A new technique , 1991, Journal of magnetic resonance imaging : JMRI.

[154]  Electron spin resonance (ESR) probe for interventional MRI instrument localization , 1999, Journal of magnetic resonance imaging : JMRI.

[155]  Reza Razavi,et al.  Accelerated 3D catheter visualization from triplanar MR projection images , 2010, Magnetic resonance in medicine.

[156]  Wolfhard Semmler,et al.  Real-time MR navigation and localization of an intravascular catheter with ferromagnetic components , 2010, Magnetic Resonance Materials in Physics, Biology and Medicine.

[157]  D. Noll,et al.  Homodyne detection in magnetic resonance imaging. , 1991, IEEE transactions on medical imaging.

[158]  L P Panych,et al.  Partial wavelet encoding: A new approach for accelerating temporal resolution in contrast‐enhanced MR imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[159]  C. Moonen,et al.  Real‐time MR‐thermometry and dosimetry for interventional guidance on abdominal organs , 2010, Magnetic resonance in medicine.

[160]  H. Ward,et al.  Spherical navigator echoes for full 3D rigid body motion measurement in MRI , 2002 .

[161]  D L Rubin,et al.  Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging. , 1990, Investigative radiology.